Search bioRxivSearch

bioRxiv · 10.1101/401836

Rapid energy expenditure estimation for assisted and inclined loaded walking

Abstract

BackgroundEstimating energy expenditure with indirect calorimetry requires expensive equipment and provides slow and noisy measurements. Rapid estimates using wearable sensors would enable techniques like optimizing assistive devices outside a lab. Existing methods correlate data from wearable sensors to measured energy expenditure without evaluating the accuracy of the estimated energy expenditure for activity conditions or subjects not included in the correlation process. Our goal is to assess data-driven models that are capable of rapidly estimating energy expenditure for new conditions and subjects.\n\nMethodsWe developed models that estimated energy expenditure from two datasets during walking conditions with (1) ankle exoskeleton assistance and (2) various loads and inclines. The estimation was portable and rapid, using input features that are possible to measure with wearable sensors and restricting the input data length to a single gait cycle or four second interval. The performance of the models was evaluated for three use cases. The first case estimated energy expenditure during walking conditions for subjects with some subject specific training data available. The second case estimated all conditions in the dataset for a new subject not included in the training data. The third case estimated new conditions for a new subject. The models also ordered the magnitude of energy expenditure across all conditions for a new subject.\n\nResultsThe average errors in energy expenditure estimation during assisted walking conditions were 4.4%, 8.0%, and 8.1% for the three use cases, respectively. The average errors in energy expenditure estimation during inclined and loaded walking conditions were 6.1%, 9.7%, and 11.7% for the three use cases. The models ordered the magnitude of energy expenditure with a maximum and average percentage of correctly ordered conditions of 56% and 43% for assisted walking and 85% and 55% for incline and loaded walking.\n\nConclusionsOur data-driven models determined the accuracy of energy expenditure estimation for three use cases. For experiments where the accuracy of a data-driven model is sufficient, standard indirect calorimetry can be replaced. The energy expenditure ordering could aid in selecting optimal assistance conditions. The models, code, and datasets are provided for reproduction and extension of our results.

Source connections

Explore related subjects

Keep this discovery

BibTeXRIS

Slade, P., Troutman, R., Kochenderfer, M. J., Collins, S. H., Delp, S. L.. 2018-09-05. Rapid energy expenditure estimation for assisted and inclined loaded walking. https://doi.org/10.1101/401836

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering