Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.02.10.704848

A cardiac pulse signal affects local field potentials recorded from deep brain stimulation electrodes across clinical targets

Abstract

ObjectiveMany deep brain stimulation (DBS) systems sense local field potentials (LFPs) for patient monitoring or closed-loop therapy (CL-DBS). LFPs can be impacted by artifacts, including a recently discovered cardiac non-electrocardiographic pulse signal that can be visually masked by commercial device filters. We aimed to establish its prevalence across patient groups and brain areas, and to investigate its spectral impact. MethodsWe performed a cross-sectional analysis of LFPs recorded from the cranially mounted Picostim from the pedunculopontine nucleus in multiple systems atrophy patients, periacqueductal gray and sensory thalamus in chronic pain patients, and the centromedian thalamic nucleus (CMT) in paediatric epilepsy patients. For comparison, we analyse externalised recordings from the subthalamic nucleus in Parkinsons disease patients. The PulsAr algorithm was developed to detect and extract pulsatile signals, and we characterised contamination level and spectral content. ResultsThough not visually obvious in CMT, the pulsatile signal was algorithmically detected in all targets, with 33% of LFPs across targets classed as contaminated. Pulse signal power was similar across targets and may have been masked by higher endogenous activity in CMT. While its dominant frequencies were in the heartbeat range, the signal had spectral content extending up to >10Hz. ConclusionsA heart pulse signal affects LFP recordings from DBS leads across brain regions and patient groups. While masked by some device filters, spectral content can extend into higher (clinically relevant) frequencies. Researchers and clinicians should exercise caution when sensing lower LFP frequencies, especially for automated control of therapy in CL-DBS. HighlightsO_LIHistorically, electrocardiographic artifacts have been a major source of artifact affecting deep brain stimulation recordings, however pulsatile artifact is less well described. C_LIO_LIA cardiac pulse signal affects local field potentials recorded from deep brain stimulation electrodes across clinical targets. C_LIO_LIWe introduce an ECG-independent algorithm that detects and extracts this pulsatile signal. C_LIO_LIThe heart pulse signal looks like the intracranial pressure waveform and affects spectral frequencies above the heart rate range up to >10Hz. C_LIO_LIClinicians should incorporate screening and procedures to ensure accurate biomarker detection for clinical decision making. C_LI

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tourigny, K. R., Piper, R. J., Tisdall, M., Neumann, W.-J., Green, A. L., Denison, T., Van Rheede, J. J.. 2026-02-11. A cardiac pulse signal affects local field potentials recorded from deep brain stimulation electrodes across clinical targets. https://doi.org/10.64898/2026.02.10.704848

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Single-Component Photo-Crosslinked Lipoic Acid Functionalized Mucin Hydrogels: Dynamic Mucus Mimetics for Antiviral Protection

Native mucus protects epithelial surfaces through viscoelastic networks of disulfide-linked mucins. However, commercially available mucins often fail to reconstitute comparable mechanical and barrier properties, while synthetic and hybrid mucus mimetics require polymeric crosslinkers that may alter mucus-like composition. Inspired by the native architecture, we directly functionalized porcine gastric and bovine submaxillary mucins with -lipoic acid to develop a single-component, photo-crosslinkable hydrogels. Upon UV irradiation (365 nm), the modified mucins rapidly form disulfide-crosslinked networks without added photo-initiator/ polymeric crosslinkers, two orders of magnitude faster as compared with PEG-SH approaches. The resulting mucin-lipoic acid (MUC-LA) hydrogels exhibit mucus-relevant properties, including tunable viscoelasticity, redox responsiveness, self-healing, and size-dependent restrictions on nanoparticle transport. In transwell-based infection models, MUC-LA hydrogels (2-3%) mimicking the healthy airway mucus (G' {approx} 10-20 Pa) suppress epithelial infection by SARS-CoV-2 and influenza A virus. Crosslinked MUC-LA provides greater protection against SARS-CoV-2 than the non-crosslinked, whereas both formulations suppress influenza A infection, suggesting distinct contributions from network formation and mucin-associated interactions. These findings establish a dynamic, mucus-mimetic platform integrating rapid photo-gelation, controllable mechanics, selective transport, and antiviral barrier functionality. MUC-LA hydrogels offer opportunities to investigate mucosal transport and host-pathogen interactions, with potential applications in drug delivery, and as biomaterials.

bioengineering↗

Population-level emulation enables fast Bayesian calibration of cardiac digital twins

Purpose: Patient-specific cardiac digital twins have the potential to guide individualized therapy, but generating these in a routine clinical workflow remains challenging. This is especially true when the twins must carry quantified uncertainty: Bayesian calibration requires thousands of simulations per patient, and the emulators that reduce this cost are typically trained one patient at a time. We aimed to train a single emulator across a patient cohort, so that a new patient can be calibrated in minutes without new simulations. Methods: We trained a population-level Gaussian process emulator whose inputs included a 12-dimensional latent encoding of the clinical features of each patient, so that a single emulator represents the whole cohort. We compared spending simulation budgets on resampling the real cohort with augmenting the cohort with digital chimeras, synthetic patients interpolated between real patients. Seven parameters of a closed-loop heart and circulation model were calibrated by Markov chain Monte Carlo to ten clinical biomarkers in 26 patients with left bundle branch block, each using an emulator trained without that patient, and the calibrated posteriors were compared against the full simulator. Results: A single emulator, trained without the held-out patient, calibrated the digital twin of each patient in 59.7-63.0 s per patient, versus 15 h with the simulator. Resampling the real cohort was the more efficient training strategy, bringing every output to R2 greater than or equal to 0.9, which augmentation did not achieve for the same simulation budget. For held-out patients, both strategies performed comparably (median leave-one-out normalized root-mean-square error 11.0% vs. 10.7%; p = 0.745), and error rose with distance from the cohort centroid (Spearman rho = +0.406). The calibrated models showed no cohort-wide bias (median standardized residual -0.12 against the clinical targets), and 95% predictive intervals contained 78.5% of targets, with the largest misfit in systolic blood pressure. Conclusion: Removing the need for new simulations for every new patient is a meaningful step toward uncertainty-aware cardiac digital twins that fit within a routine clinical workflow. Because the simulator, surrogate and sampler are interchangeable, the approach used here can be applied to other (cardiac) models and cohorts.

bioengineering↗

Multi-Structure Segmentation of Type B Aortic Dissection from CT Images with U-Net

Type B aortic dissection (TBAD) is a life-threatening condition in which a tear in the intimal layer separates the aortic wall into a true and a false lumen. Assessment of the lumen, the intimal flap, and false-lumen thrombosis from CT images is important for risk analysis and treatment planning. This work applied U-Net-based deep neural networks to the automatic segmentation of these structures in TBAD. We collected 46 CT scans from 20 patients, with voxel-wise annotations of three structures: the aortic lumen, the intimal flap, and the thrombus. We explored four models: two convolutional networks, nnU-Net 2D and 3D, and two transformer-based architectures, TransUNet 2D and 3D. We observed that (1) for both nnU-Net and TransUNet, the 3D models outperformed their 2D counterparts on all three structures. The difference was small for the aortic lumen but large for the thin flap and the thrombus. The best model, nnU-Net 3D, reached a DSC of 93.05% for the lumen, 50.22% for the flap, and 69.94% for the thrombus. (2) The intimal flap was the most difficult structure for all models. Even the best 3D models showed large thrombus boundary errors in a few scans. These results provide a baseline for developing more advanced models for accurate segmentation of these structures in TBAD.

bioengineering↗