Physiological Artifacts and the Implications for Brain-Machine-Interface Design

The accurate measurement of brain activity by Brain-Machine-Interfaces (BMI) and closed-loop Deep Brain Stimulators (DBS) is one of the most important steps in communicating between the brain and subsequent processing blocks. In conventional chest-mounted systems, frequently used in DBS, a significant amount of artifact can be induced in the sensing interface, often as a common-mode signal applied between the case and the sensing electrodes. Attenuating this common-mode signal can be a serious challenge in these systems due to finite commonmode-rejection-ratio (CMRR) capability in the interface. Emerging BMI and DBS devices are being developed which can mount on the skull. Mounting the system on the cranial region can potentially suppress these induced physiological signals by limiting the artifact amplitude. In this study, we model the effect of artifacts by focusing on cardiac activity, using a current-source dipole model in a torso-shaped volume conductor. Performing finite element simulation with the different DBS architectures, we estimate the ECG common mode artifacts for several device architectures. Using this model helps define the overall requirements for the total system CMRR to maintain resolution of brain activity. The results of the simulations estimate that the cardiac artifacts for skull-mounted systems will have a significantly lower effect than non-cranial systems that include the pectoral region. It is expected that with a pectoral mounted device, a minimum of 60-80 dB CMRR is required to suppress the ECG artifact, while in cranially-mounted devices, a 20 dB CMRR is sufficient, in the worst-case scenario. The methods used for estimating cardiac artifacts can be extended to other sources such as motion/muscle sources. The susceptibility of the device to artifacts has significant implications for the practical translation of closed-loop DBS and BMI, including the choice of biomarkers and the design requirements for insulators and lead systems.

bioengineering

Chronic wireless streaming of invasive neural recordings at home for circuit discovery and adaptive stimulation

Invasive neural recording in humans shows promise for understanding the circuit basis of brain disorders. Most recordings have been done for short durations from externalized brain leads in hospital settings, or from first-generation implantable sensing devices that offer only intermittent brief streaming of time series data. Here we report the first human use of an implantable neural interface for wireless multichannel streaming of field potentials over long periods, with and without simultaneous therapeutic neurostimulation, untethered to receiving devices. Four Parkinsons disease patients streamed bilateral 4-channel motor cortical and basal ganglia field potentials at home for over 500 hours, paired with wearable monitors that behaviorally categorize states of inadequate or excessive movement. Motor state during normal home activities was efficiently decoded using either supervised learning or unsupervised clustering algorithms. This platform supports adaptive deep brain stimulation, and may be widely applicable to brain disorders treatable by invasive neuromodulation.

neuroscience