Search bioRxiv⌕ Search

bioRxiv · 10.1101/2024.03.25.586659

Hamstrings are stretched more and faster during accelerative running compared to speed-matched constant speed running

Abstract

BackgroundHamstring strain injuries are associated with significant time away from sport and high reinjury rates. Recent evidence suggests that hamstring injuries often occur during accelerative running, but investigations of hamstring mechanics have primarily examined constant speed running on a treadmill. To help fill this gap in knowledge, this study compares hamstring lengths and lengthening velocities between accelerative running and constant speed overground running. MethodsWe recorded 2 synchronized videos of 10 participants (5 female, 5 male) during 6 accelerative running trials and 6 constant speed running trials. We used OpenCap (a markerless motion capture system) to estimate body segment kinematics for each trial and a 3-dimensional musculoskeletal model to compute peak length and step-average lengthening velocity of the biceps femoris (long head) muscle-tendon unit. To compare running conditions, we used linear mixed regression models with running speed (normalized by the subject-specific maximum) as the independent variable. ResultsAt running speeds below 75% of top speed accelerative running resulted in greater peak lengths than constant speed running. For example, the peak hamstring muscle-tendon length when a person accelerated from running at only 50% of top speed was equivalent to running at a constant 88% of top speed. Lengthening velocities were greater during accelerative running at all running speeds. Differences in hip flexion kinematics primarily drove the greater peak muscle-tendon lengths and lengthening velocities observed in accelerative running. ConclusionHamstrings are subjected to longer muscle-tendon lengths and faster lengthening velocities in accelerative running compared to constant speed running. This provides a biomechanical explanation for the observation that hamstring strain injuries often occur during acceleration. Our results suggest coaches who monitor exposure to high-risk circumstances (long lengths, fast lengthening velocities) should consider the accelerative nature of running in addition to running speed.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gurchiek, R. D., Teplin, Z., Falisse, A., Hicks, J. L., Delp, S. L.. 2024-03-29. Hamstrings are stretched more and faster during accelerative running compared to speed-matched constant speed running. https://doi.org/10.1101/2024.03.25.586659

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Single-Component Photo-Crosslinked Lipoic Acid Functionalized Mucin Hydrogels: Dynamic Mucus Mimetics for Antiviral Protection

Native mucus protects epithelial surfaces through viscoelastic networks of disulfide-linked mucins. However, commercially available mucins often fail to reconstitute comparable mechanical and barrier properties, while synthetic and hybrid mucus mimetics require polymeric crosslinkers that may alter mucus-like composition. Inspired by the native architecture, we directly functionalized porcine gastric and bovine submaxillary mucins with -lipoic acid to develop a single-component, photo-crosslinkable hydrogels. Upon UV irradiation (365 nm), the modified mucins rapidly form disulfide-crosslinked networks without added photo-initiator/ polymeric crosslinkers, two orders of magnitude faster as compared with PEG-SH approaches. The resulting mucin-lipoic acid (MUC-LA) hydrogels exhibit mucus-relevant properties, including tunable viscoelasticity, redox responsiveness, self-healing, and size-dependent restrictions on nanoparticle transport. In transwell-based infection models, MUC-LA hydrogels (2-3%) mimicking the healthy airway mucus (G' {approx} 10-20 Pa) suppress epithelial infection by SARS-CoV-2 and influenza A virus. Crosslinked MUC-LA provides greater protection against SARS-CoV-2 than the non-crosslinked, whereas both formulations suppress influenza A infection, suggesting distinct contributions from network formation and mucin-associated interactions. These findings establish a dynamic, mucus-mimetic platform integrating rapid photo-gelation, controllable mechanics, selective transport, and antiviral barrier functionality. MUC-LA hydrogels offer opportunities to investigate mucosal transport and host-pathogen interactions, with potential applications in drug delivery, and as biomaterials.

bioengineering↗

A Fibrous Optofluidic Probe for Endovascular Sensing of Blood Oxygenation and Flow Velocity

Local hemodynamic information including blood oxygenation and flow velocity could guide vascular interventions, yet obtaining these parameters in deep, narrow vessels remains challenging. Here, we report a flexible, submillimeter-scale fibrous optofluidic probe for endovascular sensing of blood oxygenation and flow velocity. The probe integrates a polymer optical fiber for light transmission with a microfluidic tube for dye injection, enabling spectroscopic oximetry and fluorescence dilution-based velocimetry through a single device. Via vascular intervention, we demonstrate local hemodynamic sensing in rabbit arteries and angiography-guided deployment in canine carotid arteries. The probe captures local changes in blood oxygenation and flow velocity during vascular occlusion and reperfusion, revealing hemodynamic disturbances that are not reflected in peripheral monitors. These results illustrate the complementary information provided by local oximetry and velocimetry and establish a compact optofluidic platform for quantitative hemodynamic monitoring during vascular interventions.

bioengineering↗

Broad-spectrum in situ genetic reprogramming of native microbiomes

Complex microbial communities are found throughout terrestrial, aquatic, and animal-associated ecosystems. Genetic modification of discrete microbial taxa within native communities represents a powerful tool to study and augment microbiome functions. Herein, we develop Synthetic Phage Assisted Reprogrammable and Targetable Addition (SPARTA) as a one-step strategy for packaging, delivering, and integrating large synthetic DNA into a broad range of native microbiomes. SPARTA leverages a broad-spectrum synthetic phage particle for in situ genome engineering within complex soil, freshwater, and mammalian fecal microbiomes, reprogramming 59 native species across 16 families. By modulating SPARTA components, we further demonstrated tunability of SPARTA towards targeted microbiome population. Additionally, we built a novel companion tool to quantitatively identify engineered taxa, named 16S crRNA-guided inference of bacterial engineering sequencing or ScRibe-seq. The SPARTA-ScRibe-seq pipeline delivered and validated functional synthetic gene clusters in diverse native microbiomes while preserving the original microbial community structure. Together, this novel genome engineering framework constitutes an end-to-end programmable platform for rational and customizable reprogramming of native microbiomes.

bioengineering↗