Search bioRxiv⌕ Search

bioRxiv · 10.1101/2023.09.07.556747

Image-based parametric finite element modelling for studying contact mechanics in human knee joints

Abstract

PurposeThis study presents a framework for generating patient-specific finite element models, parameterised and optimised for contact mechanics from computed tomography (CT) scans, by avoiding the segmentation step usually employed to transform medical images into 3D models. Two morphological parameters affecting contact mechanics were investigated in the framework development: tibial cartilage thickness and tibial spine height. This study explores the effect of the interplay of these parameters in load sharing between meniscus and articulating cartilage, meniscal posterior and anterior roots strain and menisci kine-matics. MethodsMorphological measurements from four knee CT scans were collected, such as the maximum thickness of the tibial cartilage (ranging from 1.1 to 5.2 mm), the height of the tibial spine (ranging from 3.55 to 10.1 mm), and the width of the tibial plateau in both the coronal (ranging from 27.3 to 36.17 mm) and sagittal (ranging from 31.79 to 53.77 mm) planes. These measurements were taken for the lateral tibial plateau for both left and right knees. Subsequently, three finite element (FE) models were generated, comprising lateral tibial plateaus, lateral femoral condyle and lateral meniscus. The tibial cartilage thickness was kept at a constant value of 1 mm while varying the tibial spine height within the range measured from the CT images. This resulted in three FE models with varying spine heights, categorised as large (height = 7.42 mm), medium (height = 4.25 mm), and small (height = 1.63 mm) tibial spine heights. The menisci in the FE models were generated to be congruent with the tibial plateau. For the first time, this study advances the representations of the knee menisci microstructure in FE modelling, such that we have generated meniscus FE models with three layers of a hyperelastic model in which layer thickness and layer-specific hyperelastic material parameters are derived from our previous experimental work. ResultsThe load sharing between the meniscus and articular cartilage was not sensitive to the varying tibial spine heights. In all three FE models, cartilage carried more than 90% of the applied load. However, the meniscus kinematics and root strains varied considerably with changing tibial spine heights. The small tibial spine height model predicted the highest meniscus movements (8.12 and 9.33 mm in the radial and circumferential directions, respectively) and the highest root strain (21.92 and 22.19 mm/mm in the anterior and posterior roots, respectively). ConclusionOur framework can generate finite element models of patients knees using clinical data (i.e., CT scans) without the need for lengthy image segmentation. This process is not only time-efficient but also independent of imaging operators. The models converge quickly ({inverted question}30 minutes on 2 cores) using an implicit solver with non-linear geometry and have the capability to predict contact mechanics between the articulating surfaces, meniscus kinematics and root strains. The modelling strategy presented here can provide valuable insights into predicting changes in the mechanics of soft tissues in the knee joint. It is particularly useful for investigating injury and surgical mechanisms related to the meniscus.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Readioff, R., Seil, R., Mouton, C., Marks, L., Barrera, O.. 2023-09-10. Image-based parametric finite element modelling for studying contact mechanics in human knee joints. https://doi.org/10.1101/2023.09.07.556747

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Synergy-informed bilevel optimization reveals joint-specific benefits for realistic exoskeleton torque prediction

Simulation-driven optimization can guide exoskeleton control design, but its utility is limited by the accuracy with which muscle coordination is predicted. Strict effort-minimization formulations predict non-physiological muscle shutdown under high exoskeleton assistance, leading to peak assistive torques that exceed values reported in human-in-the-loop experiments. We evaluated the accuracy of synergy-informed simulations at predicting assistance across four single-joint exoskeleton configurations: ankle plantarflexion, knee extension, hip flexion, and hip abduction. We implemented a bilevel optimization to predict a parameterized assistive torque that minimizes metabolic cost, with assisted muscle dynamics estimated via either effort-minimization simulations (minimizing muscle effort only) or synergy-informed simulations (minimizing muscle effort constrained to a synergy structure). We used experimental data from five unimpaired adults walking at their preferred speed and compared results descriptively between the two formulations within each subject. Assistance based on effort-minimization simulations shut down agonist muscle activations and overestimated peak assistive torque compared with experimental values. In contrast, constraining muscle controls to a synergy structure prevented non-physiological muscle shutdown and yielded assistive torques closer to those measured in human-in-the-loop experiments. This benefit was not observed equally across all assisted degrees of freedom or subjects, emerging only where no single synergy could be suppressed to unload the assisted muscles. Synergy weights can therefore be interpreted as joint-specific predictors of when simulations can reliably inform wearable robot design.

bioengineering↗

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗