Search bioRxiv⌕ Search

Biology subjects

Seil, R.

Publications and source records attributed to Seil, R..

2 recordsLinked to original sources

Mechanics of knee meniscus results from precise balance between material microstructure and synovial fluid viscosity

The meniscus plays a crucial role in the biomechanics of the knee, serving as load transmitter, and reducing friction between joints. Understanding the biome-chanics of the meniscus is essential to effective treatments of knee injuries and degenerative conditions. In this study, we used two central meniscus samples extracted from a human knee and acquired high-resolution {micro}-CT images. Using an implicit immersed boundary technique, we reconstructed two 3D computational models of the menisci. By eroding the channels of the original meniscus geometry, we created new microstructures with varying porosities (0.53 to 0.8) whilst preserving the connectivity of the porous structure. We investigate the fluid dynamics of the meniscus using a mesh-free numerical method, considering various inlet pressure conditions and analysing the fluid flow within the microstructures. The results of the original microstructure associated with a physiological dynamic viscosity of synovial fluid are in accordance with biophysical experiments on menisci. Furthermore, the eroded microstructure with a 33% increase in porosity exhibited a remarkable 120% increase in flow velocity. This emphasises the sensitivity of meniscus physiology to porous microstructure properties, showing that detailed computational models can explore physiological and pathological conditions, advancing further knee biomechanics research.

bioengineering↗

Image-based parametric finite element modelling for studying contact mechanics in human knee joints

PurposeThis study presents a framework for generating patient-specific finite element models, parameterised and optimised for contact mechanics from computed tomography (CT) scans, by avoiding the segmentation step usually employed to transform medical images into 3D models. Two morphological parameters affecting contact mechanics were investigated in the framework development: tibial cartilage thickness and tibial spine height. This study explores the effect of the interplay of these parameters in load sharing between meniscus and articulating cartilage, meniscal posterior and anterior roots strain and menisci kine-matics. MethodsMorphological measurements from four knee CT scans were collected, such as the maximum thickness of the tibial cartilage (ranging from 1.1 to 5.2 mm), the height of the tibial spine (ranging from 3.55 to 10.1 mm), and the width of the tibial plateau in both the coronal (ranging from 27.3 to 36.17 mm) and sagittal (ranging from 31.79 to 53.77 mm) planes. These measurements were taken for the lateral tibial plateau for both left and right knees. Subsequently, three finite element (FE) models were generated, comprising lateral tibial plateaus, lateral femoral condyle and lateral meniscus. The tibial cartilage thickness was kept at a constant value of 1 mm while varying the tibial spine height within the range measured from the CT images. This resulted in three FE models with varying spine heights, categorised as large (height = 7.42 mm), medium (height = 4.25 mm), and small (height = 1.63 mm) tibial spine heights. The menisci in the FE models were generated to be congruent with the tibial plateau. For the first time, this study advances the representations of the knee menisci microstructure in FE modelling, such that we have generated meniscus FE models with three layers of a hyperelastic model in which layer thickness and layer-specific hyperelastic material parameters are derived from our previous experimental work. ResultsThe load sharing between the meniscus and articular cartilage was not sensitive to the varying tibial spine heights. In all three FE models, cartilage carried more than 90% of the applied load. However, the meniscus kinematics and root strains varied considerably with changing tibial spine heights. The small tibial spine height model predicted the highest meniscus movements (8.12 and 9.33 mm in the radial and circumferential directions, respectively) and the highest root strain (21.92 and 22.19 mm/mm in the anterior and posterior roots, respectively). ConclusionOur framework can generate finite element models of patients knees using clinical data (i.e., CT scans) without the need for lengthy image segmentation. This process is not only time-efficient but also independent of imaging operators. The models converge quickly ({inverted question}30 minutes on 2 cores) using an implicit solver with non-linear geometry and have the capability to predict contact mechanics between the articulating surfaces, meniscus kinematics and root strains. The modelling strategy presented here can provide valuable insights into predicting changes in the mechanics of soft tissues in the knee joint. It is particularly useful for investigating injury and surgical mechanisms related to the meniscus.

bioengineering↗