bioRxiv · 10.1101/2023.01.24.525317
Ramped V1 transcranial ultrasonic stimulation modulates but does not evoke visual evoked potentials
Abstract
Transcranial ultrasonic stimulation (TUS), has been shown to evoke visual evoked potential (VEP)-like potentials on EEG recordings, and also to modulate sensory evoked potentials. However, pulsed TUS is accompanied by an auditory confound, and it is possible that any observed effects were, in-part, evoked by this confound. Therefore, we used ramped TUS pulses, which are not as easily audible, to examine whether primary visual cortex (V1) TUS evokes VEP-like potentials, and modulates VEPs elicited using a checkerboard stimulus. MethodsWe tested 14 healthy participants (31 {+/-} 4.3 yrs, 4 F and 10 M). TUS was applied to the left V1 using a 270 kHz transducer (H115-2AA, Sonic Concepts). Ramped pulses (1 ms ramp, 3.25 ms total pulse duration) were repeated at 250 Hz, with a pulse train duration of 300 ms, an effective duty cycle of 50%, and Isppa without ramping of 16 W/cm2 in water. EEG was recorded from 16 channels using the g.USBamp amplifier (g.tec medical engineering GmbH). In two blocks (TUS-only), real and sham (100 each) TUS trials were repeated every 2 s. In another two blocks (TUS+checkerboard), a checkerboard stimulus was flipped every 0.5 s, and every fourth stimulus was associated with either a real or sham (100 each) TUS trial. The TUS trial started approx. 130 ms (0-5 ms jitter) before the checkerboard flip. All EEG data were analysed using Fieldtrip, and cluster-based permutation tests were used to test for differences between conditions. Results and discussionIn the TUS-only condition, in contrast to a previous study, we found no evoked potentials using ramped pulses which minimised the auditory artifact. In the TUS+checkerboard condition, we observed a modulation of the early-component of the VEP in real TUS, relative to no TUS trials. This suggests that, in line with in-vitro and animal data, there is a direct neuromodulatory effect of ultrasound, in addition to any confounding effects. Moving forward, ramping offers a relatively easy approach to minimise the auditory confound.
Source connections
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Nandi, T., Johnstone, A., Martin, E., Cooper, R., Bestmann, S., Bergmann, T. O., Treeby, B., Stagg, C. J.. 2023-01-24. Ramped V1 transcranial ultrasonic stimulation modulates but does not evoke visual evoked potentials. https://doi.org/10.1101/2023.01.24.525317
Cite the original work for its findings. Save a collection to share your selection of sources.