Abstract

During standing, posture can be controlled by accelerating the Center of Mass (CoM) through shifting the center of pressure (CoP) within the base of support by applying ankle moments ("CoP mechanism"), or through the "counter-rotation mechanism", i.e., changing the angular momentum of segments around the CoM to change the direction of the ground reaction force. Postural control develops over the lifespan; at both the beginning and the end of the lifespan adequate postural control appears more challenging. In this study, we aimed to assess mediolateral balance performance and the related use of the postural control mechanisms in children, older adults and young adults when standing on different (unstable) surfaces. Sixteen pre-pubertal children (6-9y), 17 young adults (18-24y) and eight older adults (65-80y) performed bipedal upright standing trials of 16 seconds on a rigid surface and on three balance boards that could freely move in the frontal plane, varying in height (15-19 cm) of the surface of the board above the point of contact with the floor. Full body kinematics (16 segments, 48 markers, using SIMI 3D-motion analysis system (GmbH) and DeepLabCut and Anipose) were retrieved. Performance related outcome measures, i.e., the number of trials with balance loss and the Root Mean Square (RMS) of the time series of the CoM acceleration, the contributions of the CoP mechanism and the counter-rotation mechanism to the CoM acceleration in the frontal plane and selected kinematic measures, i.e. the orientation of the board and the head and the Mean Power Frequency (MPF) of the balance board orientation and the CoM acceleration were determined. Balance loss only occurred when standing on the highest balance board, twice in one older adult once in one young adult. In children and older adults, the RMS of the CoM accelerations were larger, corresponding to poorer balance performance. Across age groups and conditions, the contribution of the CoP mechanism to the total CoM acceleration was much larger than that of the counter-rotation mechanisms, ranging from 94%-113% vs 23%-38% (with totals higher than 100% indicating opposite effects of both mechanisms). Deviations in head orientation were small compared to deviations in balance board orientation. We hypothesize that the CoP mechanism is dominant, since the counter-rotation mechanism would conflict with stabilizing the orientation of the head in space.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

van den Bogaart, M., Bruijn, S. M., Spildooren, J., van Dieën, J. H., Meyns, P.. 2021-09-09. Effects of age and surface instability on the control of the center of mass. https://doi.org/10.1101/2021.09.08.459390

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗

PROST: An Open Toolbox, Harmonised Multi-Lab Dataset, and Meta-Analysis of Ankle-Foot Roll-Over Shape

The ankle-foot roll-over shape (ROS) is the sagittal-plane path of the centre of pressure (CoP) during the stance phase of walking, expressed in a shank-based coordinate system. It describes the effective rocker geometry that emerges from both the shape and the elastic deformation of the ankle-foot system during walking, and informs prosthetic and orthotic design. Previous studies characterised ROS in small samples with differing laboratory protocols, so they have not systematically assessed inter-individual variability or its relation to anthropometrics. We developed the open-source Public ROS Toolbox (PROST) for standardised ROS computation, and used it to harmonise marker trajectories, ground reaction forces and CoP data from four public gait datasets collected in independent laboratories. For each leg, we fitted a circular arc to the pooled ROS of all its stance phases. In a one-stage individual-participant data meta-analysis, linear mixed-effects models, with dataset as a fixed effect and participant as a random intercept, related the arc radius and the horizontal coordinate of the circle centre to anthropometrics, and, in the two self-selected-speed datasets, to walking speed. The harmonised dataset comprises 249 participants and 5,667 stance phases at walking speeds of 0.7-8.5 km/h. Circular arcs fitted the ROS closely (mean RMS radial residual 1.9 mm). The radius had a median of 410.3 mm (interquartile range, IQR, 237.6 mm), and the circle centre lay posterior to the ankle (median -20.6 mm, IQR 49.5 mm). Between-participant differences, quantified by the intraclass correlation coefficient (ICC), accounted for 42% of the variance in log radius (95% CI 25-57%) and 47% of the variance in the horizontal coordinate of the circle centre (95% CI 24-65%). Anthropometrics explained a negligible share of this variance (radius: pseudo-R2 -0.001, 95% CI -0.03 to 0.12), and height normalisation did not reduce radius variability (robust coefficient of variation 43% with and without normalisation). Faster self-selected walking was associated with a larger radius and a more posterior circle centre. To our knowledge, this study provides the first harmonised multi-lab ROS dataset. Together with the open-source toolbox, it is publicly available to support reproducible research in gait biomechanics, rehabilitation device design and clinical gait assessment. ROS geometry was participant-specific but was not predicted by age, sex, height or mass. A device ROS scaled from anthropometrics is therefore unlikely to match an individual's ROS, motivating studies of whether matching it, through device geometry and stiffness, improves gait mechanics.

bioengineering↗