bioRxiv · 10.1101/2021.05.10.442867
High-Stability Polyimide-based Flexible Electrodes with IrOx to Interface the Mouse Vagus Nerve
Abstract
ObjectiveWe developed robust and cost-effective cuff Flex electrodes to facilitate bioelectronic medicine research in mouse models. They utilize polyimide (PI) as a dielectric insulation and iridium oxide (IrOx) for the electrodes, and are designed to interface small autonomic and somatic nerves (e.g. mouse vagus nerve). ApproachFlex electrodes were made using micro-fabrication technology, and innovative integration processes were developed to enable reliable acute and chronic vagus nerve interfaces. The electrochemical properties of Flex electrodes were characterized. Moreover, accelerated aging at 57 {degrees}C and stimulation-stability (Stim-Stab) testing (109 pulses at [~] 1.59 mC/cm2/phase) were performed to evaluate the lifetime of the PI encapsulation and IrOx electrodes, respectively. Flex electrodes efficacy was demonstrated by stimulating the mouse vagus nerve ([~]100 {micro}m) and measuring heart and respiratory rate changes as biomarkers. ResultsCost effective and robust lead and connector integration strategies were demonstrated, including small helical leads that improved the lead elongation by > 7x. PI encapsulation had stable impedance spectra for at least 336 days for interdigitated electrodes. Stim-Stab testing using an aggressive paradigm and rigorous optical and electrical characterization, revealed that half of electrodes showed less than minor damage at the endpoints. A trend of decreasing respiratory rate with stimulation current reached statistical significance at 500 {micro}A, demonstrating efficacy for Flex electrodes. SignificanceFlex electrodes offer demonstrated efficacy, low impedance (443 {+/-} 32 {Omega} at 103 Hz), excellent bench test stability, and cost-effective fabrication. Acute devices are easy to integrate, and mechanically robust chronic devices will be investigated in vivo in future studies. These characteristics make the electrodes well-positioned to advance bioelectronics medicine research by 1) enabling reliable studies with statistically relevant populations of acute mouse models, and 2) offering the potential for a technology that can be used in chronic studies, which scales to very small nerves.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Sun, T., Falcone, J. D., Crosfield, C., Lopez, M. F., Peragine, J., Modi, R., Sharma, R., Baker, B., Anderson, G., Savani, S., Li, C., Chang, E. H., Sohal, H., Rieth, L.. 2021-05-11. High-Stability Polyimide-based Flexible Electrodes with IrOx to Interface the Mouse Vagus Nerve. https://doi.org/10.1101/2021.05.10.442867
Cite the original work for its findings. Save a collection to share your selection of sources.