Search bioRxiv⌕ Search

Biology subjects

Rieth, L.

Publications and source records attributed to Rieth, L..

8 recordsLinked to original sources

Systematic Errors in DC Offset Measurement and Mitigation at Neurostimulation Electrodes: Causes, Implications and Solutions

Objective: Neuromodulation therapies are becoming increasingly common as a therapeutic strategy to treat neurological disorders and deficits. Despite their widespread use, the frameworks used to evaluate device longevity and electrochemical safety are limited, producing variable results for platinum (Pt) electrodes across studies. In addition, next-generation neuromodulation electrodes like thin-film microelectrode arrays (TFMEAs) are more prone to failure by virtue of their smaller size, higher edge to bulk ratios, and greater sensitivity to electrochemical dissolution processes. Two potential contributors to the variability in reported electrochemical safety limits and device performance are particularly sensitive to scaling electrodes to smaller geometries, namely: 1) insufficient measurement device input impedance and 2) unmitigated stimulator leakage currents. Approach: To explore these effects, we first characterize the impact of electrode size (1.27 x 10-4 to 7.85 x 10-3 cm2) on apparent open circuit potential (VaOCP) and interpulse potential (VIPP) measurements at platinum electrodes across measurement instrumentation configurations. Next, we evaluated the effectiveness of commonly used DC mitigation strategies, including stimulation with capacitive coupling (CC), and with capacitive coupling combined with cathode/anode shorting after each pulse (CC+ES), as a function of electrode size. Main Results: Without proper DC mitigation, insufficient measurement input impedance leads to an underestimation of DC offsets ({Delta}VIPP) and, consequently, a misrepresentation of charge injection limits (Qinj) at Pt electrodes. In contrast, when DC offsets are properly mitigated and the input impedance of the measurement device is sufficient, the experimentally derived charge injection limits for Pt electrodes are larger than what has been reported historically. Significance: By identifying the instrumentation-related confounds biasing measurements of electrochemical safety limits, this work provides a more consistent basis for the assessment of Qinj for safety, as well as a framework for identifying and mitigating DC offset as a potential source of variability in electrophysiological findings across studies using TFMEAs.

neuroscience↗

In vivo optogenetics using a Utah Optrode Array with enhanced light output and spatial selectivity

Optogenetics allows manipulation of neural circuits in vivo with high spatial and temporal precision. However, combining this precision with control over a significant portion of the brain is technologically challenging (especially in larger animal models). Here, we have developed, optimised, and tested in vivo, the Utah Optrode Array (UOA), an electrically addressable array of optical needles and interstitial sites illuminated by 181 {micro}LEDs and used to optogenetically stimulate the brain. The device is specifically designed for non-human primate studies. Thinning the combined {micro}LED and needle backplane of the device from 300 {micro}m to 230 {micro}m improved the efficiency of light delivery to tissue by 80%, allowing lower {micro}LED drive currents, which improved power management and thermal performance. The spatial selectivity of each site was also improved by integrating an optical interposer to reduce stray light emission. These improvements were achieved using an innovative fabrication method to create an anodically bonded glass/silicon substrate with through-silicon vias etched, forming an optical interposer. Optical modelling was used to demonstrate that the tip structure of the device had a major influence on the illumination pattern. The thermal performance was evaluated through a combination of modelling and experiment, in order to ensure that cortical tissue temperatures did not rise by more than 1{degrees}C. The device was tested in vivo in the visual cortex of macaque expressing ChR2-tdTomato in cortical neurons. It was shown that the strongest optogenetic response occurred in the region surrounding the needle tips, and that the extent of the optogenetic response matched the predicted illumination profile based on optical modelling - demonstrating the improved spatial selectivity resulting from the optical interposer approach. Furthermore, different needle illumination sites generated different patterns of low-frequency potential (LFP) activity.

neuroscience↗

Flexible IrOx Neural Electrode for Mouse Vagus Nerve Stimulation

Vagus nerve stimulation (VNS) is being actively explored as a treatment for multiple conditions as part of bioelectronic medicine research. Reliable and safe VNS in mouse models is a critical need for understanding mechanisms of these. We report on the development and evaluation of a microfabricated cuff electrode (MouseFlex) constructed of polyimide (PI) and with iridium oxide (IrOx) electrodes that is thermoformed to 86 {micro}m {+/-} 12 {micro}m radius to interface the mouse cervical vagus nerve (r {approx} 50 {micro}m). Innovative bench-top methods were used to evaluated the stimulation stability and electrochemical properties of electrodes. Our aggressive stimulation stability (Stim-Stab) test utilized 1 billion pulses at a 1000 Hz with a current density of 6.28 A/cm2 (1.51 mC/cm2/phase) to evaluate electrode lifetimes, and all electrodes remained functional. We also investigated the effects of thermoforming on their impedance, charge storage capacity (CSC), and charge injection capacity (CIC). The modest changes in electrochemical properties indicate that the thermoforming process was well tolerated. Thermoformed electrode safety and efficacy were evaluated in-vivo by performing acute VNS in mice and monitoring their heart and respiration rate as biomarkers. Their electrochemical properties were also measured before, during and after VNS. Bradycardia and bradypnea were reliably induced at stimulation currents of 100 to 200 {micro}A, well below the in-vivo CIC of ~1250 {micro}A (~0.5 mC/cm2), supporting their safety and efficacy. The electrode impedance increased and CIC decreased during in-vivo use, but largely reversed these changes in in-vitro testing after enzymatic cleaning, supporting their tolerance for surgical use.

bioengineering↗

An Optrode Array for Spatiotemporally Precise Large-Scale Optogenetic Stimulation of Deep Cortical Layers in Non-human Primates

Optogenetics has transformed studies of neural circuit function, but remains challenging to apply in large brains, such as those of non-human primates (NHPs). A major challenge is delivering intense, spatiotemporally precise, patterned photostimulation across large volumes in deep tissue. Such stimulation is critical, for example, to modulate selectively deep-layer corticocortical feedback projections. To address this unmet need, we have developed the Utah Optrode Array (UOA), a 10x10 glass needle waveguide array fabricated atop a novel opaque optical interposer then bonded to an electrically addressable LED array. In vivo experiments with the UOA demonstrated large-scale, spatiotemporally precise, activation of deep circuits in monkey cortex. Specifically, the UOA permitted both focal (confined to single layers/columns), and widespread (multiple layers/columns) optogenetic activation of deep layer neurons, simply by varying the number of activated LEDs and/or the irradiance. Thus, the UOA represents a powerful optoelectronic device for targeted manipulation of deep-layer circuits in NHP models.

neuroscience↗

High-Stability Polyimide-based Flexible Electrodes with IrOx to Interface the Mouse Vagus Nerve

ObjectiveWe developed robust and cost-effective cuff Flex electrodes to facilitate bioelectronic medicine research in mouse models. They utilize polyimide (PI) as a dielectric insulation and iridium oxide (IrOx) for the electrodes, and are designed to interface small autonomic and somatic nerves (e.g. mouse vagus nerve). ApproachFlex electrodes were made using micro-fabrication technology, and innovative integration processes were developed to enable reliable acute and chronic vagus nerve interfaces. The electrochemical properties of Flex electrodes were characterized. Moreover, accelerated aging at 57 {degrees}C and stimulation-stability (Stim-Stab) testing (109 pulses at [~] 1.59 mC/cm2/phase) were performed to evaluate the lifetime of the PI encapsulation and IrOx electrodes, respectively. Flex electrodes efficacy was demonstrated by stimulating the mouse vagus nerve ([~]100 {micro}m) and measuring heart and respiratory rate changes as biomarkers. ResultsCost effective and robust lead and connector integration strategies were demonstrated, including small helical leads that improved the lead elongation by > 7x. PI encapsulation had stable impedance spectra for at least 336 days for interdigitated electrodes. Stim-Stab testing using an aggressive paradigm and rigorous optical and electrical characterization, revealed that half of electrodes showed less than minor damage at the endpoints. A trend of decreasing respiratory rate with stimulation current reached statistical significance at 500 {micro}A, demonstrating efficacy for Flex electrodes. SignificanceFlex electrodes offer demonstrated efficacy, low impedance (443 {+/-} 32 {Omega} at 103 Hz), excellent bench test stability, and cost-effective fabrication. Acute devices are easy to integrate, and mechanically robust chronic devices will be investigated in vivo in future studies. These characteristics make the electrodes well-positioned to advance bioelectronics medicine research by 1) enabling reliable studies with statistically relevant populations of acute mouse models, and 2) offering the potential for a technology that can be used in chronic studies, which scales to very small nerves.

bioengineering↗

Implant- and anesthesia-related factors affecting threshold intensities for vagus nerve stimulation

Vagus nerve stimulation (VNS) is used as therapy in epilepsy and depression and is tested as a potential treatment for several chronic disorders. Typically, VNS is delivered at increasing stimulus intensity until a response is observed (threshold intensity). Factors that affect threshold intensities for engagement of different fiber types and concomitant physiological responses have not been studied. We determined neural and physiological responses to increasing stimulus intensities of VNS in anesthetized and awake animals, and examined the effect of implant- and anesthesia-related factors on threshold intensities in a rodent model of VNS. In acute and long-term cervical vagus nerve implants (53 and 14 rats, respectively) VNS was delivered under isoflurane, ketamine-xylazine, or awake at different intensities. Stimulus-evoked compound action potentials (eCAPs) were recorded, elicited physiological responses were registered, including changes heart rate (HR), breathing, and blood pressure (BP), and threshold intensities were determined. The intensity that elicits eCAPs ("neural threshold") is significantly lower than what elicits a physiological response ("physiological threshold", PT) (25 A {+/-}1.8 vs. 70 A {+/-}5.2, respectively; Mean {+/-}SEM). Changes in BP occur at the lowest stimulus intensities (80 A {+/-}7), followed by changes in HR (105 A {+/-}8.4) and finally in breathing (310 A {+/-}32.5). PT is lower with than without electrode insulation (60 A {+/-}12, vs. 700 A {+/-}123). PT and electrode impedance are correlated in long-term (r=0.47; p<0.001) but not in acute implants (r=-0.34; p NS); both PT and impedance increase with implant age (Pearson correlation r=0.44; p<0.001 and r=0.64; p<0.001, respectively). PT is lowest when animals are awake (210 A {+/-}33; Mean {+/-}SEM), followed by ketamine-xylazine (630 A {+/-}154), and isoflurane (1075 A {+/-}131). The sequence of physiological responses with increasing VNS intensity is similar in both anesthetized and awake states. Implant age, electrical impedance and the type of anesthesia affect VNS threshold and should be accounted for when determining stimulation dose.

bioengineering↗

Analytical characterization of Parylene-C degradation mechanisms on Utah arrays: evaluation of in vitro Reactive Accelerated Aging model compared to multiyear in vivo implantation

Implantable neural microelectrodes are integral components of neuroprosthetic technologies and can transform treatments for many neural-mediated disorders. However, dielectric material degradation during long-term (> 1 year) indwelling periods restricts device functional lifetimes to a few years. This comprehensive work carefully investigates in vivo material degradation and also explores the ability of in vitro Reactive Accelerated Aging (RAA) to evaluate implant stability. Parylene C-coated Utah electrode arrays (UEAs) implanted in feline peripheral nerve for 3.25 years were explanted and compared to RAA-processed devices, aged in phosphate buffered saline (PBS) + 20 mM H2O2 at either 67 or 87 {degrees}C (28 or 7 days, respectively). Electron microscopy revealed similar physical damage characteristics between explants and RAA (87{degrees} C) devices. Parylene C degradation was overwhelmingly apparent for UEAs from both RAA cohorts. Controls aged in PBS alone displayed almost no damage. Spectroscopic characterization (EDX, XPS, FTIR) found clear indications of oxidation and chlorine abstraction for parylene C aged in vivo. While in vitro aging was also accompanied by signs of oxidation, changes in the chemistry in vivo and in vitro were statistically different. Analysis of RAA- aged devices identified UEA fabrication approaches that may greatly improve device resistance to degradation. This work underscores the need for an improved understanding of in vivo damage mechanisms, to facilitate the critical need for representative in vitro accelerated testing paradigms for long-term implants.

bioengineering↗

A multi-site MicroLED Optrode Array for Neural Interfacing

We present an electrically addressable optrode array capable of delivering light to 181 sites in the brain, each providing sufficient light to optogenetically excite hundreds of neurons in vivo, developed with the aim to allow behavioural studies in large mammals. The device is a glass microneedle array directly integrated with a custom fabricated microLED device, which delivers light to 100 needle tips and 81 interstitial surface sites, giving 2-level optogenetic excitation of neurons in vivo. Light delivery and thermal properties are evaluated, with the device capable of peak irradiances > 80 mW/mm2 per needle at 50 ms pulse widths with tissue temperature increase less than 1 {degrees}C. Future designs are explored through optical and thermal modelling and benchmarked against the current device.

neuroscience↗