Evaluation of an Orbitrap Astral Zoom mass spectrometer prototype for quantitative proteomics - beyond identification lists

Mass spectrometry instrumentation continues to evolve rapidly yet quantifying these advances beyond conventional peptide and protein detections remain challenging. Here, we evaluate a modified Orbitrap Astral Zoom mass spectrometer (MS) prototype and compare its performance to the standard Orbitrap Astral MS. Across a range of acquisition methods and sample inputs, the prototype instrument outperformed the standard Orbitrap Astral MS in precursor and protein identifications, ion beam utilization, and quantitative precision. To enable meaningful cross-platform comparisons, we implemented an ion calibration framework that converts signal intensity from arbitrary units to ion per second. This benchmarking strategy showed that the prototype sampled 30% more ions per peptide than the original Orbitrap Astral MS. This increase in the ion beam utilization resulted in improved sensitivity and quantitative precision. To make these metrics broadly accessible, we added new metrics to the Skyline document grid to report the number of ions measured in a spectrum at the apex of the elution peak or the sum of ions between the peak integration boundaries. Taken together, our results demonstrate the prototype Orbitrap Astral Zoom as a high-performance platform for DIA proteomics and establish a generalizable framework for evaluation of mass spectrometer performance based on the number of ions detected for each analyte. Data are available on Panorama Public and on ProteomeXchange under the identifier PXD064536.

biochemistry↗

Expanding Targeted Instrumentation for Discovery Applications: Complement Reporter Ion Quantification with a Quadrupole-Ion Trap Instrument

Proteomics workflows have traditionally been divided into discovery-based and targeted approaches, with instrumentation optimized specifically for each. Discovery experiments typically utilize high-resolution analyzers while targeted workflows rely on the sensitivity and specificity of triple quadrupole systems. Recently, a quadrupole-ion trap instrument (Stellar MS) demonstrated superior performance for targeted applications compared to conventional triple quadrupoles. In this study, we expand the capabilities of this platform to multiplexed shotgun proteomics using complement reporter ion quantification in an ion trap (iTMTproC). Benchmarking experiments with defined standards show that iTMTproC achieves quantification accuracy and interference reduction comparable to MultiNotch MS3 on the Orbitrap Fusion Lumos, a dedicated quadrupole-ion trap-Orbitrap tribrid instrument optimized for this purpose. Notably, iTMTproC quantifies slightly more proteins than MultiNotch MS3. We further validate this approach through a developmental time-series analysis of frog embryos, obtaining proteomic data nearly indistinguishable from MultiNotch MS3, with slightly increased protein quantification depth. These findings significantly extend the functionality of targeted instrumentation, underscoring the versatility of quadrupole-ion trap systems and providing cost-effective access to highly accurate, multiplexed quantitative shotgun proteomics.

systems biology↗

Development and Clinical Evaluation of a Multiplexed Health Surveillance Panel Using Ultra High-Throughput PRM-MS in an Inflammatory Bowel Disease Cohort.

Despite advances in clinical proteomics, translating protein biomarker discoveries into clinical use remains challenging due to the technical complexity of the validation process. Targeted MS-based proteomics approaches such as parallel reaction monitoring (PRM) offer sensitive and specific assays for biomarker translation. In this study, we developed a multiplex PRM assay using the Stellar mass spectrometry platform to quantify 57 plasma proteins, including 21 FDA-approved proteins. Loading curves (11-points) were performed at 4 sample throughputs (100, 144, 180, and 300 samples per day) using independent, optimized, and scheduled PRM methods. Following optimization, an inflammatory bowel disease (IBD) cohort of plasma samples (493 IBD, 509 matched controls) was analyzed at a throughput of 180 SPD. To monitor system performance, the study also included 1,000 additional injections for system suitability tests, low-, middle-, and high-quality controls, washes, and blanks. Using this approach, we observed high quantifiability (linearity, sensitivity, reproducibility) in the PRM assay and consistent in data acquisition across a large cohort. We also validated the candidate IBD markers, C-reactive protein and orosomucoid protein, identified in a recent discovery experiment.

biochemistry↗

Development of highly multiplex targeted proteomics assays in biofluids using the Stellar mass spectrometer

The development of targeted assays that monitor biomedically relevant proteins is an important step in bridging discovery experiments to large scale clinical studies. Targeted assays are currently unable to scale to hundreds or thousands of targets. We demonstrate the generation of large-scale assays using a novel hybrid nominal mass instrument. The scale of these assays is achievable with the StellarTM mass spectrometer through the accommodation of shifting retention times by real-time alignment, while being sensitive and fast enough to handle many concurrent targets. Assays were constructed using precursor information from gas-phase fractionated (GPF) data-independent acquisition (DIA). We demonstrate the ability to schedule methods from an orbitrap and linear ion trap acquired GPF DIA library and compare the quantification of a matrix-matched calibration curve from orbitrap DIA and linear ion trap parallel reaction monitoring (PRM). Two applications of these proposed workflows are shown with a cerebrospinal fluid (CSF) neurodegenerative disease protein PRM assay and with a Mag-Net enriched plasma extracellular vesicle (EV) protein survey PRM assay.

biochemistry↗

Hybrid Quadrupole Mass Filter Radial Ejection Linear Ion Trap and Intelligent Data Acquisition Enable Highly Multiplex Targeted Proteomics

Targeted mass spectrometry (MS) methods are powerful tools for selective and sensitive analysis of peptides identified by global discovery experiments. Selected reaction monitoring (SRM) is currently the most widely accepted MS method in the clinic, due to its reliability and analytical performance. However, due to limited throughput and the difficulty in setting up and analyzing large scale assays, SRM and parallel reaction monitoring (PRM) are typically used only for very refined assays of on the order of 100 targets or less. Here we introduce a new MS platform with a quadrupole mass filter, collision cell, linear ion trap architecture that has increased acquisition rates compared to the analogous hardware found in the Orbitrap Tribrid series instruments. The platform can target more analytes than existing SRM and PRM instruments - in the range of 5000 to 8000 peptides per hour. This capability for high multiplexing is enabled by acquisition rates of 70-100 Hz for peptide applications, and the incorporation of real-time chromatogram alignment that adjusts for retention time drift and enables narrow time scheduled acquisition windows. Finally, we describe a Skyline external software tool that implements the building of targeted methods based on data independent acquisition chromatogram libraries or unscheduled analysis of heavy labeled standards. We show that the platform delivers ~10x lower LOQs than traditional SRM analysis for a highly multiplex assay and also demonstrate how analytical figures of merit change while varying method duration with a constant number of analytes, or by keeping a constant time duration while varying the number of analytes.

biochemistry↗

A workflow for targeted proteomics assay development using a versatile linear ion trap

Advances in proteomics and mass spectrometry have enabled the study of limited cell populations, such as single-cell proteomics, where high-mass accuracy instruments are typically required. While triple quadrupoles offer fast and sensitive nominal resolution measurements, these instruments are effectively limited to targeted proteomics. Linear ion traps (LITs) offer a versatile, cost-effective alternative capable of both targeted and global proteomics. We demonstrate a workflow using a newly released, hybrid quadrupole-LIT instrument for developing targeted proteomics assays from global data-independent acquisition (DIA) measurements without needing high-mass accuracy. Gas-phase fraction-based DIA enables rapid target library generation in the same background chemical matrix as each quantitative injection. Using a new software tool embedded within EncyclopeDIA for scheduling parallel reaction monitoring assays, we show consistent quantification across three orders of magnitude of input material. Using this approach, we demonstrate measuring peptide quantitative linearity down to 25x dilution in a background of only a 1 ng proteome without requiring stable isotope labeled standards. At 1 ng total protein on column, we found clear consistency between immune cell populations measured using flow cytometry and immune markers measured using LIT-based proteomics. We believe hybrid quadrupole-LIT instruments represent an economic solution to democratizing mass spectrometry in a wide variety of laboratory settings.

biochemistry↗

Evaluating the performance of the Astral mass analyzer for quantitative proteomics using data independent acquisition

We evaluate the quantitative performance of the newly released Asymmetric Track Lossless (Astral) analyzer. Using data independent acquisition, the Thermo Scientific Orbitrap Astral mass spectrometer quantifies 5 times more peptides per unit time than state-of-the-art Thermo Scientific Orbitrap mass spectrometers, which have long been the gold standard for high resolution quantitative proteomics. Our results demonstrate that the Orbitrap Astral mass spectrometer can produce high quality quantitative measurements across a wide dynamic range. We also use a newly developed extra-cellular vesicle enrichment protocol to reach new depths of coverage in the plasma proteome, quantifying over 5,000 plasma proteins in a 60-minute gradient with the Orbitrap Astral mass spectrometer.

biochemistry↗

Dynamic Data Independent Acquisition Mass Spectrometry with Real-Time Retrospective Alignment

We report a data independent acquisition (DIA) strategy that dynamically adjusts the tandem mass spectrometry (MS/MS) windows during the chromatographic separation. The method focuses MS/MS acquisition on the most relevant mass range at each point in time - improving the quantitative sensitivity by increasing the time spent on each DIA window. We demonstrate an improved lower limit of quantification, on average, without sacrificing the number of peptides detected.

bioinformatics↗

Comparison of unit resolution versus high-resolution accurate mass for parallel reaction monitoring

Parallel reaction monitoring (PRM) is an increasingly popular alternative to selected reaction monitoring (SRM) for targeted proteomics. PRMs strengths over SRM are that it monitors all product ions in a single spectrum, thus eliminating the need to select interference-free product ions prior to data acquisition, and that it is most frequently performed on high-resolution instruments, such as quadrupole-orbitrap and quadrupole-time of flight instruments. Here, we show that the primary advantage of PRM is the ability to monitor all transitions in parallel, and that high-resolution data are not necessary to obtain high quality quantitative data. We run the same scheduled PRM assay, measuring 432 peptides from 126 plasma proteins, multiple times on a Orbitrap Eclipse Tribrid mass spectrometer, alternating separate liquid chromatography-tandem mass spectrometry runs between the high resolution Orbitrap and the unit resolution linear ion trap for PRM. We find that both mass analyzers have similar technical precision, and that the linear ion traps superior sensitivity gives it better lower limits of quantitation on over 62% of peptides in the assay. Abstract graphic O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=99 SRC="FIGDIR/small/442680v1_ufig1.gif" ALT="Figure 1"> View larger version (28K): org.highwire.dtl.DTLVardef@225f7dorg.highwire.dtl.DTLVardef@ab09a9org.highwire.dtl.DTLVardef@1076dfborg.highwire.dtl.DTLVardef@c5a34c_HPS_FORMAT_FIGEXP M_FIG C_FIG

biochemistry↗