Search bioRxiv⌕ Search

Biology subjects

Nkansah, A.

Publications and source records attributed to Nkansah, A..

9 recordsLinked to original sources

Off-the-Shelf Multilayer Vascular Grafts with Damage-Resistant Hydrogel Coatings Incorporating Integrin Targeting

Synthetic grafts remain ineffective for small-caliber vascular applications due to thrombosis and intimal hyperplasia. To address these limitations, our lab designed a multilayer graft consisting of a hydrogel coating that promotes post-implantation endothelialization and an electrospun mesh that matches arterial mechanical properties. Damage-resistant hydrogels were engineered using a double-network system composed of polyether urethane diacrylamide and N-acryloyl glycinamide to enhance fracture resistance through hydrogen bonding. In this study, we utilized redox initiation to apply conformal, durable hydrogels to electrospun grafts. Bioactivity wa introduced using streptococcal collagen-like proteins containing 1{beta}1 and 2{beta}1 integrin-binding motifs, enabling selective cell-material interactions that support endothelialization while preserving acute thromboresistance. To establish the feasibility of these grafts as off-the-shelf devices, we evaluated coating integrity and bioactivity retention following sterilization and dynamic physiological loading. Sterilized composites exhibited surgically-associated damage resistance, indicating that sterilization did not compromise hydrogel durability. Coating integrity and bioactivity were also preserved after six weeks of physiological loading. Acut thromboresistance was supported by both static platelet adhesion assays and dynamic whole-blood bioreactor studies using heparinized blood, with low platelet adhesion observed relative to ePTFE. Finally, a pilot ovine carotid model demonstrated successful surgical handling and sustained graft patency. Collectively, these results highlight the promise of multilayer vascular grafts as durable, thromboresistant conduits for small-diameter vascular applications. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=60 SRC="FIGDIR/small/741222v1_ufig1.gif" ALT="Figure 1"> View larger version (33K): org.highwire.dtl.DTLVardef@14ec910org.highwire.dtl.DTLVardef@17259e8org.highwire.dtl.DTLVardef@6cb611org.highwire.dtl.DTLVardef@1251d7d_HPS_FORMAT_FIGEXP M_FIG C_FIG

bioengineering↗

Mechanical History and Substrate Stiffness Shape Integrin-Mediated Endothelial Cell Behavior on Bioactive Hydrogels

Synthetic blood contacting devices frequently fail due to the lack of requisite biochemical and biomechanical cues needed to support transanastamotic endothelialization. During transanastomotic endothelialization, endothelial cells experience dynamic changes in extracellular mechanical cues as they migrate from compliant native vessels onto stiffer blood contacting device surfaces. However, how substrate stiffness and mechanical memory from prior mechanical environments influence temporal integrin remodeling and downstream endothelialization processes necessary to establish a stable endothelial layer remains poorly understood. In this study, human coronary artery endothelial cells (HCECs) were cultured on substrates spanning physiologically relevant stiffnesses to determine how substrate mechanics regulate collagen binding integrins and endothelialization. Increasing substrate stiffness promoted time dependent upregulation of 2{beta}1 integrin expression, whereas 1{beta}1 expression remained unchanged. Enhanced 2{beta}1 expression on stiff substrates was accompanied by increased vinculin associated focal adhesion maturation and accelerated endothelialization, characterized by increased proliferation, migration, and progression to confluence prior to reaching quiescence after 1 week. To better model transanastomotic migration and investigate mechanical history effects, cells initially expanded on compliant hydrogels were transferred to stiff substrates. Although these cells exhibited transient reductions in 2{beta}1 expression at early timepoints compared with tissue culture polystyrene expanded controls, no persistent differences in focal adhesion maturation, proliferation, migration, confluence, or quiescence were observed. Collectively, these findings demonstrate that substrate stiffness is a primary regulator of the early endothelialization processes required to establish a stable endothelial monolayer, whereas the influence of mechanical history is transient and ultimately superseded by the current mechanical environment. These findings also identify 2{beta}1 mediated mechanotransduction as a potential design target for blood contacting biomaterials that promote rapid endothelialization while supporting long-term endothelial cell quiescence.

bioengineering↗

Iron Regulates CD4 T Cell Quiescence by Controlling TGF-β Production

Transforming growth factor-{beta} (TGF-{beta}) regulates CD4 T cell quiescence, activation, and regulatory T cell differentiation, but its role in T cell iron metabolism is poorly defined. Here, we investigated whether TGF-{beta} regulates iron homeostasis and how iron overload alters TGF-{beta} responsiveness. During T cell activation, TGF-{beta} enhanced survival but markedly reduced proliferation. These effects were accompanied by decreased CD71 expression and cytosolic iron availability, as well as increased mitochondrial iron accumulation. Genetic deletion of TGF{beta}R1 reversed these changes, demonstrating that TGF-{beta} regulates CD4 T cell iron homeostasis through TGF{beta}R1-dependent signaling. Iron-overloaded CD4 T cells lacking the heme exporter FLVCR1 exhibit hypersensitivity to TGF-{beta}, increased TGF-{beta} secretion, and sustained TGF{beta}R1 expression upon activation. Pharmacologic inhibition of TGF{beta}R1restored proliferation, CD71 expression, and iron levels in FLVCR1-deficient cells. Although TGF-{beta} selectively induced total and mitochondrial ROS levels in FLVCR1-deficient cells, antioxidant treatment or Nox2 inhibition did not rescue this phenotype, suggesting that ROS is associated with, but not sufficient to explain, TGF-{beta} hypersensitivity. Acute FeSO4-induced iron overload partially recapitulated the phenotype of FLVCR1-deficient cells, although TGF{beta}R1 expression and TGF-{beta} production differed. Finally, regulatory T cells generated in vitro in the presence of TGF-{beta} displayed reduced iron acquisition, and excess iron impaired FoxP3 induction. Together, this work identifies TGF-{beta} as a context-dependent regulator of CD4 T cell iron homeostasis.

immunology↗

Characterization of Sex-Based Differences in Integrin-Mediated Endothelial Cel Adhesion to Bioactive Hydrogels

Endothelialization promotes thromboresistance in blood-contacting devices, but biomaterial designs often overlook sex differences in endothelialization processes. In this study, we elucidated sex differences in endothelial cell-material interactions through investigation of the integrin-ligand interplay with biomaterial substrates and the corollary effects on cell adhesion and spreading. First, integrin expression of human coronary artery endothelial cells (HCAECs) was characterized for age-matched donors (3 male, 3 female). Sex-based differences in integrin expression were identified, with notably higher 2{beta}1, 5{beta}1, and V{beta}3 expression in female cells and higher 1{beta}1 expression in male cells. On polyethylene glycol (PEG)-based hydrogel incorporating collagen or gelatin, female cells showed increased attachment on stiff substrates as compared to male HCAECs, likely driven by increased 2{beta}1, 5{beta}1, and V{beta}3 expression in female cells. Collectively, these results demonstrate sex-biased endothelial cell responses to bioactive hydrogels mediated by integrin interactions and highlight the importance of incorporating biological sex as a design variable in the development of blood-contacting biomaterials. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=72 SRC="FIGDIR/small/656802v2_ufig1.gif" ALT="Figure 1"> View larger version (33K): org.highwire.dtl.DTLVardef@41bfb9org.highwire.dtl.DTLVardef@921619org.highwire.dtl.DTLVardef@e8df4corg.highwire.dtl.DTLVardef@9c0faa_HPS_FORMAT_FIGEXP M_FIG C_FIG

bioengineering↗

Advanced Manufacturing of Coil-Reinforced Multilayer Vascular Grafts to Optimize Biomechanical Performance

Small diameter vascular grafts require a complex balance of biomechanical properties to achieve target burst pressure, arterial compliance-matching, and kink resistance to prevent failure. Iterative design of our multilayer vascular was previously used to achieve high compliance while retaining the requisite burst pressure and suture retention strength for clinical use. To impart kink resistance, a custom 3D solution printer was used to add a polymeric coil to the electrospun polyurethane graft to support the graft during bending. The addition of this reinforcing coil increased kink resistance but reduced compliance. A matrix of grafts were fabricated and tested to establish key structure-property relationships between coil parameters (spacing, diameter, modulus) and biomechanical properties (compliance, kink radius). A successful graft design was identified with a compliance similar to saphenous vein grafts (4.1 {+/-} 0.4 %/mmHgx10-2) while maintaining comparable kink resistance to grafts used currently in the clinic. To explore graft combinations that could increase graft compliance to match arterial values while retaining this kink resistance, we utilized finite element (FE) models of compliance and kink radius that simulated experimental testing. The FE-predicted graft compliance agreed well with experimental values. Although the kink model over-predicted the experimental kink radius values, key trends between graft parameters and kink resistance were reproduced. As an initial proof-of-concept, the validated models were then utilized to parse through a targeted graft design space. Although this initial parameter range tested did not yield a graft that improved upon the previous balance of graft properties, this combination of advanced manufacturing and computational framework paves the way for future model-driven design to further optimize graft performance. TOC O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=97 SRC="FIGDIR/small/633374v1_ufig1.gif" ALT="Figure 1"> View larger version (45K): org.highwire.dtl.DTLVardef@faca56org.highwire.dtl.DTLVardef@f9dccforg.highwire.dtl.DTLVardef@fbb5corg.highwire.dtl.DTLVardef@d5c021_HPS_FORMAT_FIGEXP M_FIG C_FIG

bioengineering↗

A Computational Framework to Optimize the Mechanical Behavior of Synthetic Vascular Grafts

The failure of synthetic small-diameter vascular grafts has been attributed to a mismatch in the compliance between the graft and native artery, driving mechanisms that promote thrombosis and neointimal hyperplasia. Additionally, the buckling of grafts results in large deformations that can lead to device failure. Although design features can be added to lessen the buckling potential, the addition is detrimental to decreasing compliance (e.g., reinforcing coil). Herein, we developed a novel finite element framework to inform vascular graft design by evaluating compliance and resistance to buckling. A batch-processing scheme iterated across the multi-dimensional design parameter space, which included three parameters: coil thickness, modulus, and spacing. Three types of finite element models were created in FEBio for each unique coil-reinforced graft parameter combination to simulate pressurization, axial buckling, and bent buckling, and results were analyzed to quantify compliance, buckling load, and kink radius, respectively, from each model. Importantly, model validation demonstrated that model predictions agree qualitatively and quantitatively with experimental observations. Subsequently, data for each design parameter combination were integrated into an optimization function for which a minimum value was sought. The optimization values identified various candidate graft designs with promising mechanical properties. Our investigation successfully demonstrated the model-directed framework identified vascular graft designs with optimal mechanical properties, which can potentially improve clinical outcomes by addressing device failure. In addition, the presented computational framework promotes model-directed device design for a broad range of biomaterial and regenerative medicine strategies.

bioengineering↗

Design of PEG-based hydrogels as soft ionic conductors

Conductive hydrogels have gained interest in biomedical applications and soft electronics. To tackle the challenge of ionic hydrogels falling short of desired mechanical properties in previous studies, our investigation aimed to understand the pivotal structural factors that impact the conductivity and mechanical behavior of polyethylene glycol (PEG)-based hydrogels with ionic conductivity. Polyether urethane diacrylamide (PEUDAm), a functionalized long-chain macromer based on PEG, was used to synthesize hydrogels with ionic conductivity conferred by incorporating ions into the liquid phase of hydrogel. The impact of salt concentration, water content, temperature, and gel formation on both mechanical properties and conductivity was characterized to establish parameters for tuning hydrogel properties. To further expand the range of conductivity available in these ionic hydrogels, 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) was incorporated as a single copolymer network or double network configuration. As expected, conductivity in these ionic gels was primarily driven by ion diffusivity and charge density, which was dependent on hydrogel network formation and swelling. Copolymer network structure had minimal effect on the conductivity which was primarily driven by counter-ion equilibrium; however, the mechanical properties and equilibrium swelling was strongly dependent on network structure. The structure-property relationships elucidated here enables the rationale design of this new double network hydrogel to achieve target properties for a broad range of applications.

bioengineering↗

Eliminating steam pops and improving lesion safety in atrial ablation with conductive hydrogels

BackgroundAtrial fibrillation (AF) is a significant burden worldwide, and the existing treatments leave much to be desired. There are, however, opportunities to improve the safety and efficacy of the most popular treatment, radiofrequency (RF) cardiac ablation, using conductive hydrogels as an ablation mediator. MethodsLesions were created in ex vivo ventricular tissues using bare metal traditional RF catheters and three different hydrogels with varying conductivities to assess the effect of conductivity on lesion formation. Similar procedures were performed in atrial/esophageal tissue stacks to mimic physiological AF ablation and demonstrate the initial safety profile of conductive hydrogel-mediated ablation. ResultsThe hydrogel mediated lesions were overall shallower and narrower than bare metal, and also exhibited less char and improved lesion homogeneity. The hydrogel also eliminated steam pops. Finally, the hydrogel appeared to be more thermally protective of the esophagus in the atrial/esophageal tissue stack, greatly reducing the lesion formation on the esophagus while still achieving transmural lesions in the atrial tissue. ConclusionsHydrogel-mediated RF ablation holds promise as a novel method to improve ablation outcomes for AF patients. Future work will confirm this in vivo and establish the chemistry required to create a conductive hydrogel coating for RF ablation catheters.

bioengineering↗

Hydrogel-Polyurethane Fiber Composites With Enhanced Microarchitectural Control For Heart Valve Replacement

Polymeric heart valves offer the potential to overcome the limited durability of tissue based bioprosthetic valves and the need for anticoagulant therapy of mechanical valve replacement options. However, developing a single-phase material with requisite biological properties and target mechanical properties remains a challenge. In this study, a composite heart valve material was developed where an electrospun mesh provides tunable mechanical properties and a hydrogel coating confers an antifouling surface for thromboresistance. Key biological responses were evaluated in comparison to glutaraldehyde-fixed pericardium. Platelet and bacterial attachment were reduced by 38% and 98%, respectively, as compared to pericardium that demonstrated the antifouling nature of the hydrogel coating. There was also a notable reduction (59%) in the calcification of the composite material as compared to pericardium. A custom 3D printed hydrogel coating setup was developed to make valve composites for device-level hemodynamic testing. Regurgitation fraction (9.6 {+/-} 1.8%) and effective orifice area (1.52 {+/-} 0.34 cm2) met ISO 5840-2:2021 requirements. Additionally, the mean pressure gradient was comparable to current clinical bioprosthetic heart valves demonstrating preliminary efficacy. Although the hemodynamic properties are promising, it is anticipated that the random microarchitecture will result in suboptimal strain fields and peak stresses that may accelerate leaflet fatigue and degeneration. Previous computational work has demonstrated that bioinspired fiber microarchitectures can improve strain homogeneity of valve materials toward improving durability. To this end, we developed advanced electrospinning methodologies to achieve polyurethane fiber microarchitectures that mimic or exceed the physiological ranges of alignment, tortuosity, and curvilinearity present in the native valve. Control of fiber alignment from a random fiber orientation at a normalized orientation index (NOI) 14.2 {+/-} 6.9% to highly aligned fibers at a NOI of 85.1 {+/-} 1.4%. was achieved through increasing mandrel rotational velocity. Fiber tortuosity and curvilinearity in the range of native valve features were introduced through a post-spinning annealing process and fiber collection on a conical mandrel geometry, respectively. Overall, these studies demonstrate the potential of hydrogel-polyurethane fiber composite as a heart valve material. Future studies will utilize the developed advanced electrospinning methodologies in combination with model-directed fabrication toward optimizing durability as a function of fiber microarchitecture.

bioengineering↗