Search bioRxiv⌕ Search

Biology subjects

Fairley, A.

Publications and source records attributed to Fairley, A..

4 recordsLinked to original sources

Off-the-Shelf Multilayer Vascular Grafts with Damage-Resistant Hydrogel Coatings Incorporating Integrin Targeting

Synthetic grafts remain ineffective for small-caliber vascular applications due to thrombosis and intimal hyperplasia. To address these limitations, our lab designed a multilayer graft consisting of a hydrogel coating that promotes post-implantation endothelialization and an electrospun mesh that matches arterial mechanical properties. Damage-resistant hydrogels were engineered using a double-network system composed of polyether urethane diacrylamide and N-acryloyl glycinamide to enhance fracture resistance through hydrogen bonding. In this study, we utilized redox initiation to apply conformal, durable hydrogels to electrospun grafts. Bioactivity wa introduced using streptococcal collagen-like proteins containing 1{beta}1 and 2{beta}1 integrin-binding motifs, enabling selective cell-material interactions that support endothelialization while preserving acute thromboresistance. To establish the feasibility of these grafts as off-the-shelf devices, we evaluated coating integrity and bioactivity retention following sterilization and dynamic physiological loading. Sterilized composites exhibited surgically-associated damage resistance, indicating that sterilization did not compromise hydrogel durability. Coating integrity and bioactivity were also preserved after six weeks of physiological loading. Acut thromboresistance was supported by both static platelet adhesion assays and dynamic whole-blood bioreactor studies using heparinized blood, with low platelet adhesion observed relative to ePTFE. Finally, a pilot ovine carotid model demonstrated successful surgical handling and sustained graft patency. Collectively, these results highlight the promise of multilayer vascular grafts as durable, thromboresistant conduits for small-diameter vascular applications. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=60 SRC="FIGDIR/small/741222v1_ufig1.gif" ALT="Figure 1"> View larger version (33K): org.highwire.dtl.DTLVardef@14ec910org.highwire.dtl.DTLVardef@17259e8org.highwire.dtl.DTLVardef@6cb611org.highwire.dtl.DTLVardef@1251d7d_HPS_FORMAT_FIGEXP M_FIG C_FIG

bioengineering↗

Mechanical History and Substrate Stiffness Shape Integrin-Mediated Endothelial Cell Behavior on Bioactive Hydrogels

Synthetic blood contacting devices frequently fail due to the lack of requisite biochemical and biomechanical cues needed to support transanastamotic endothelialization. During transanastomotic endothelialization, endothelial cells experience dynamic changes in extracellular mechanical cues as they migrate from compliant native vessels onto stiffer blood contacting device surfaces. However, how substrate stiffness and mechanical memory from prior mechanical environments influence temporal integrin remodeling and downstream endothelialization processes necessary to establish a stable endothelial layer remains poorly understood. In this study, human coronary artery endothelial cells (HCECs) were cultured on substrates spanning physiologically relevant stiffnesses to determine how substrate mechanics regulate collagen binding integrins and endothelialization. Increasing substrate stiffness promoted time dependent upregulation of 2{beta}1 integrin expression, whereas 1{beta}1 expression remained unchanged. Enhanced 2{beta}1 expression on stiff substrates was accompanied by increased vinculin associated focal adhesion maturation and accelerated endothelialization, characterized by increased proliferation, migration, and progression to confluence prior to reaching quiescence after 1 week. To better model transanastomotic migration and investigate mechanical history effects, cells initially expanded on compliant hydrogels were transferred to stiff substrates. Although these cells exhibited transient reductions in 2{beta}1 expression at early timepoints compared with tissue culture polystyrene expanded controls, no persistent differences in focal adhesion maturation, proliferation, migration, confluence, or quiescence were observed. Collectively, these findings demonstrate that substrate stiffness is a primary regulator of the early endothelialization processes required to establish a stable endothelial monolayer, whereas the influence of mechanical history is transient and ultimately superseded by the current mechanical environment. These findings also identify 2{beta}1 mediated mechanotransduction as a potential design target for blood contacting biomaterials that promote rapid endothelialization while supporting long-term endothelial cell quiescence.

bioengineering↗

Characterization of Sex-Based Differences in Integrin-Mediated Endothelial Cel Adhesion to Bioactive Hydrogels

Endothelialization promotes thromboresistance in blood-contacting devices, but biomaterial designs often overlook sex differences in endothelialization processes. In this study, we elucidated sex differences in endothelial cell-material interactions through investigation of the integrin-ligand interplay with biomaterial substrates and the corollary effects on cell adhesion and spreading. First, integrin expression of human coronary artery endothelial cells (HCAECs) was characterized for age-matched donors (3 male, 3 female). Sex-based differences in integrin expression were identified, with notably higher 2{beta}1, 5{beta}1, and V{beta}3 expression in female cells and higher 1{beta}1 expression in male cells. On polyethylene glycol (PEG)-based hydrogel incorporating collagen or gelatin, female cells showed increased attachment on stiff substrates as compared to male HCAECs, likely driven by increased 2{beta}1, 5{beta}1, and V{beta}3 expression in female cells. Collectively, these results demonstrate sex-biased endothelial cell responses to bioactive hydrogels mediated by integrin interactions and highlight the importance of incorporating biological sex as a design variable in the development of blood-contacting biomaterials. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=72 SRC="FIGDIR/small/656802v2_ufig1.gif" ALT="Figure 1"> View larger version (33K): org.highwire.dtl.DTLVardef@41bfb9org.highwire.dtl.DTLVardef@921619org.highwire.dtl.DTLVardef@e8df4corg.highwire.dtl.DTLVardef@9c0faa_HPS_FORMAT_FIGEXP M_FIG C_FIG

bioengineering↗

Hydrogel-Polyurethane Fiber Composites With Enhanced Microarchitectural Control For Heart Valve Replacement

Polymeric heart valves offer the potential to overcome the limited durability of tissue based bioprosthetic valves and the need for anticoagulant therapy of mechanical valve replacement options. However, developing a single-phase material with requisite biological properties and target mechanical properties remains a challenge. In this study, a composite heart valve material was developed where an electrospun mesh provides tunable mechanical properties and a hydrogel coating confers an antifouling surface for thromboresistance. Key biological responses were evaluated in comparison to glutaraldehyde-fixed pericardium. Platelet and bacterial attachment were reduced by 38% and 98%, respectively, as compared to pericardium that demonstrated the antifouling nature of the hydrogel coating. There was also a notable reduction (59%) in the calcification of the composite material as compared to pericardium. A custom 3D printed hydrogel coating setup was developed to make valve composites for device-level hemodynamic testing. Regurgitation fraction (9.6 {+/-} 1.8%) and effective orifice area (1.52 {+/-} 0.34 cm2) met ISO 5840-2:2021 requirements. Additionally, the mean pressure gradient was comparable to current clinical bioprosthetic heart valves demonstrating preliminary efficacy. Although the hemodynamic properties are promising, it is anticipated that the random microarchitecture will result in suboptimal strain fields and peak stresses that may accelerate leaflet fatigue and degeneration. Previous computational work has demonstrated that bioinspired fiber microarchitectures can improve strain homogeneity of valve materials toward improving durability. To this end, we developed advanced electrospinning methodologies to achieve polyurethane fiber microarchitectures that mimic or exceed the physiological ranges of alignment, tortuosity, and curvilinearity present in the native valve. Control of fiber alignment from a random fiber orientation at a normalized orientation index (NOI) 14.2 {+/-} 6.9% to highly aligned fibers at a NOI of 85.1 {+/-} 1.4%. was achieved through increasing mandrel rotational velocity. Fiber tortuosity and curvilinearity in the range of native valve features were introduced through a post-spinning annealing process and fiber collection on a conical mandrel geometry, respectively. Overall, these studies demonstrate the potential of hydrogel-polyurethane fiber composite as a heart valve material. Future studies will utilize the developed advanced electrospinning methodologies in combination with model-directed fabrication toward optimizing durability as a function of fiber microarchitecture.

bioengineering↗