Search bioRxiv⌕ Search

Biology subjects

Bowles, W.

Publications and source records attributed to Bowles, W..

2 recordsLinked to original sources

Reduction of SEM charging artefacts in native cryogenic biological samples.

Scanning electron microscopy (SEM) of frozen-hydrated biological samples allows imaging of subcellular structures at the mesoscale in their native state. Combined with focused ion beam milling (FIB), serial FIB/SEM can be used to build a 3-dimensional picture of cells and tissues. The correlation of specific regions of interest with cryo-electron microscopy (cryoEM) can additionally enable subsequent high-resolution analysis. However, the adoption of serial FIB/SEM imaging-based methods is limited due to artefacts arising from insulating areas of cryogenically preserved samples. Here, we demonstrate the use of interleaved scanning to reduce charging artefacts, allowing the observation of biological features that otherwise would be masked or perturbed. We apply our method to samples where inherent features are not visible. These examples include membrane contact sites within mammalian cells, visualisation of the degradation compartment in the algae E.gracilis and observation of a network of membranes within different types of axons in an adult mouse cortex. We further propose an alternative scanning method that could also be widely applicable to imaging any non-conductive.

cell biology↗

Cryo-plasma FIB/SEM volume imaging of biological specimens

Serial focussed ion beam scanning electron microscopy (FIB/SEM) enables imaging and assessment of sub-cellular structures on the mesoscale (10 nm to 10 m). When applied to vitrified samples, serial FIB/SEM is also a means to target specific structures in cells and tissues while maintaining constituents hydration shells for in-situ structural biology downstream. However, the application of serial FIB/SEM imaging of non-stained cryogenic biological samples is limited due to low contrast, curtaining and charging artefacts. We address these challenges using a cryogenic plasma FIB/SEM (cryo-pFIB/SEM). We evaluated the choice of plasma ion source and imaging regimes to produce high quality SEM images of a range of different biological samples. Using an automated workflow we produced three dimensional volumes of bacteria, human cells, and tissue, and calculated estimates for their resolution, typically achieving 20 to 50 nm. Additionally, a tag-free tool is needed to drive the application of in situ structural biology towards tissue. The combination of serial FIB/SEM with plasmabased ion sources promises a framework for targeting specific features in bulk-frozen samples (>100 m) to produce lamella for cryogenic electron tomography.

cell biology↗