Search bioRxiv⌕ Search

Biology subjects

Bekker-Jensen, D. B.

Publications and source records attributed to Bekker-Jensen, D. B..

7 recordsLinked to original sources

Fully automated workflow for integrated sample digestion and Evotip loading enabling high-throughput clinical proteomics

Protein identification and quantification is an important tool for biomarker discovery. With the increased sensitivity and speed of modern mass spectrometers, sample-preparation remains a bottleneck for studying large cohorts. To address this issue, we prepared and evaluated a simple and efficient workflow on the Opentrons OT-2 (OT-2) robot that combines sample digestion, cleanup and Evotip loading in a fully automated manner, allowing the processing of up to 192 samples in 6 hours. Our results demonstrate a highly sensitive workflow yielding both reproducibility and stability even at low sample inputs. The workflow is optimized for minimal sample starting amount to reduce the costs for reagents needed for sample preparation, which is critical when analyzing large biological cohorts. Building on the digesting workflow, we incorporated an automated phosphopeptide enrichment step using magnetic Ti-IMAC beads. This allows for a fully automated proteome and phosphoproteome sample preparation in a single step with high sensitivity. Using the integrated workflow, we evaluated the effects of cancer immune therapy on the plasma proteome in metastatic melanoma patients.

molecular biology↗

One-Tip enables comprehensive proteome coverage in minimal cells and single zygotes

We present One-Tip, a lossless proteomics methodology that seamlessly combines swift, one-pot sample preparation with narrow-window data-independent acquisition mass spectrometric analysis. With simplest sample processing, One-Tip reproducibly identifies > 9,000 proteins from [~]1000 cells and [~] 6,000 proteins in a single mouse zygote with a throughput of 40 samples-per-day. This easy-to-use method expands capabilities of proteomics research by enabling greater depth, scalability and throughput covering low to high input samples.

biochemistry↗

Spatial-proteomics reveal in-vivo phospho-signaling dynamics at subcellular resolution

Dynamic change in subcellular localization of signaling proteins is a general concept that eukaryotic cells evolved for eliciting a coordinated response to stimuli. Mass spectrometry (MS)-based proteomics in combination with subcellular fractionation can provide comprehensive maps of spatio-temporal regulation of cells, but involves laborious workflows that does not cover the phospho-proteome level. Here we present a high-throughput workflow based on sequential cell fractionation to profile the global proteome and phospho-proteome dynamics across six distinct subcellular fractions. We benchmarked the workflow by studying spatio-temporal EGFR phospho-signaling dynamics in-vitro in HeLa cells and in-vivo in mouse tissues. Finally, we investigated the spatio-temporal stress signaling, revealing cellular relocation of ribosomal proteins in response to hypertonicity and muscle contraction. Proteomics data generated in this study can be explored through https://SpatialProteoDynamics.github.io.

systems biology↗

Causal integration of multi-omics data with prior knowledge to generate mechanistic hypotheses

Multi-omics datasets can provide molecular insights beyond the sum of individual omics. Diverse tools have been recently developed to integrate such datasets, but there are limited strategies to systematically extract mechanistic hypotheses from them. Here, we present COSMOS (Causal Oriented Search of Multi-Omics Space), a method that integrates phosphoproteomics, transcriptomics, and metabolics datasets. COSMOS combines extensive prior knowledge of signaling, metabolic, and gene regulatory networks with computational methods to estimate activities of transcription factors and kinases as well as network-level causal reasoning. COSMOS provides mechanistic hypotheses for experimental observations across multi-omics datasets. We applied COSMOS to a dataset comprising transcriptomics, phosphoproteomics, and metabolomics data from healthy and cancerous tissue from nine renal cell carcinoma patients. We used COSMOS to generate novel hypotheses such as the impact of Androgen Receptor on nucleoside metabolism and the influence of the JAK-STAT pathway on propionyl coenzyme A production. We expect that our freely available method will be broadly useful to extract mechanistic insights from multi-omics studies. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=86 SRC="FIGDIR/small/057893v1_ufig1.gif" ALT="Figure 1"> View larger version (28K): org.highwire.dtl.DTLVardef@37d2d7org.highwire.dtl.DTLVardef@f333d4org.highwire.dtl.DTLVardef@cfcac3org.highwire.dtl.DTLVardef@90318_HPS_FORMAT_FIGEXP M_FIG C_FIG

bioinformatics↗

A Compact Quadrupole-Orbitrap Mass Spectrometer with FAIMS Interface Improves Proteome Coverage in Short LC Gradients

State-of-the-art proteomics-grade mass spectrometers can measure peptide precursors and their fragments with ppm mass accuracy at sequencing speeds of tens of peptides per second with attomolar sensitivity. Here we describe a compact and robust quadrupole-orbitrap mass spectrometer equipped with a front-end High Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) Interface. The performance of the Orbitrap Exploris 480 mass spectrometer is evaluated in data-dependent acquisition (DDA) and data-independent acquisition (DIA) modes in combination with FAIMS. We demonstrate that different compensation voltages (CVs) for FAIMS are optimal for DDA and DIA, respectively. Combining DIA with FAIMS using single CVs, the instrument surpasses 2500 unique peptides identified per minute. This enables quantification of >5000 proteins with short online LC gradients delivered by the Evosep One LC system allowing acquisition of 60 samples per day. The raw sensitivity of the instrument is evaluated by analyzing 5 ng of a HeLa digest from which >1000 proteins were reproducibly identified with 5 minute LC gradients using DIA-FAIMS. To demonstrate the versatility of the instrument we recorded an organ-wide map of proteome expression across 12 rat tissues quantified by tandem mass tags and label-free quantification using DIA with FAIMS to a depth of >10,000 proteins.

biochemistry↗

Rapid and site-specific deep phosphoproteome profiling by data-independent acquisition (DIA) without the need for spectral libraries

Quantitative phosphoproteomics has in recent years revolutionized understanding of cell signaling, but it remains a challenge to scale the technology for high-throughput analyses. Here we present a rapid and reproducible phosphoproteomics approach to systematically analyze hundreds of samples by fast liquid chromatography tandem mass spectrometry using data independent acquisition (DIA). To overcome the inherent issue of positional phosphopeptide isomers in DIA-based phosphoproteomics, we developed and employed an accurate site localization scoring algorithm, which is incorporated into the Spectronaut software tool. Using a library of synthetic phosphopeptides spiked-in to a yeast phosphoproteome in different ratios we show that it is on par with the top site localization score for data-dependent acquisition (DDA) based phosphoproteomics. Single-shot DIA-based phosphoproteomics achieved an order of magnitude broader dynamic range, higher reproducibility of identification and improved sensitivity and accuracy of quantification compared to state-of-the-art DDA-based phosphoproteomics. Importantly, direct DIA without the need of spectral libraries performed almost on par with analyses using specific project-specific libraries. Moreover, we implemented and benchmarked an algorithm for globally determining phosphorylation site stoichiometry in DIA. Finally, we demonstrate the scalability of the DIA approach by systematically analyzing the effects of thirty different kinase inhibitors in context of epidermal growth factor (EGF) signaling showing that a large proportion of EGF-dependent phospho-regulation is mediated by a specific set of protein kinases.

biochemistry↗

A novel LC system embeds analytes in pre-formed gradients for rapid, ultra-robust proteomics

To further integrate mass spectrometry (MS)-based proteomics into biomedical research and especially into clinical settings, high throughput and robustness are essential requirements. They are largely met in high-flow rate chromatographic systems for small molecules but these are not sufficiently sensitive for proteomics applications. Here we describe a new concept that delivers on these requirements while maintaining the sensitivity of current nano-flow LC systems. Low-pressure pumps elute the sample from a disposable trap column, simultaneously forming a chromatographic gradient that is stored in a long storage loop. An auxiliary gradient creates an offset, ensuring the re-focusing of the peptides before the separation on the analytical column by a single high-pressure pump. This simplified design enables robust operation over thousands of sample injections. Furthermore, the steps between injections are performed in parallel, reducing overhead time to a few minutes and allowing analysis of more than 200 samples per day. From fractionated HeLa cell lysates, deep proteomes covering more than 130,000 sequence unique peptides and close to 10,000 proteins were rapidly acquired. Using this data as a library, we demonstrate quantitation of 5200 proteins in only 21 min. Thus, the new system-termed Evosep One-analyzes samples in an extremely robust and high throughput manner, without sacrificing in depth proteomics coverage.

biochemistry↗