Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.11.24.769044

GASTON-VI efficiently quantifies spatial axes and molecular gradients from multi-sample, multi-modal spatial-omics data

Abstract

Many tissues exhibit an underlying spatial axis along which fundamental biological processes occur due to continuous spatial gradients of cell type and molecular state. Modern spatial-omics technologies measure molecular features (e.g. gene/protein expression) at 100,000s-1,000,000s of locations within a two-dimensional (2-D) tissue slice, with large-scale atlases profiling multiple tissue slices of the same organ type across different individuals and biological conditions (e.g. healthy versus diseased). However, existing computational methods for identifying spatial molecular gradients are limited to small spatial transcriptomics datasets (1000s of cells) of a single tissue slice, while methods for integrating multiple samples do not explicitly model spatial axes nor spatial molecular gradients along such axes. Here, we present GASTON-VI, a variational inference (VI)-based deep learning model which efficiently learns an underlying spatial axis and spatial molecular gradients along this axis from multi-sample, multi-condition spatial-omics data of any molecular modality (e.g. transcriptomics, proteomics). GASTON-VI jointly learns (1) a spatial coordinate (the "isodepth") for each individual tissue slice and (2) 1-D spatial modality functions that describe molecular gradients along the isodepth for tissues of the same biological condition, while utilizing a latent variable model to account for batch effects. Further, GASTON-VI implements a statistical test for identifying molecules with differential spatial gradients across biological conditions (e.g. healthy versus diseased). On spatial transcriptomics and proteomics data from the intestine, tonsil, and liver, we show that GASTON-VI recovers spatial axes and molecular gradients along these axes more accurately and efficiently than existing methods. In particular, applied to large-scale spatial transcriptomics and proteomics atlases, GASTON-VI reveals differential spatial gradients of gene expression along the portal vein-central vein axis in fibrotic livers, and differential spatial gradients of protein abundance along the muscularis-lumen axis across different regions of the intestine. Software availability: GASTON-VI is available at https://github.com/chitra-lab/GASTON-VI.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ning, Z., Dharmasena, S., Chitra, U.. 2026-11-25. GASTON-VI efficiently quantifies spatial axes and molecular gradients from multi-sample, multi-modal spatial-omics data. https://doi.org/10.64898/2026.11.24.769044. https://searchbiorxiv.org/record/biorxiv%3A10.64898%2F2026.11.24.769044/gaston-vi-efficiently-quantifies-spatial-axes-and-molecular-gradients-from-multi-sample-multi-modal

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search bioRxiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related preprints

R implementation of the NORMAgene data-driven qRT-PCR normalization algorithm

Effective data normalization is essential in producing meaningful qRT-PCR results. Traditional reference gene normalization has high risk of confounds when poorly implemented, and data-driven normalization is becoming an increasingly used and robust alternative. The NORMAgene least squares-based normalization algorithm is one of the most application flexible of existing data-driven qRT-PCR normalization approaches; however, it is currently only available in the form of an unmaintained Visual Basic for Applications (VBA) macro. In order to make this approach more widely and persistently accessible, we developed an R language implementation based on the core mathematical model and made it available as a standalone package titled NORMAgene. Here, we detail the development of this package, demonstrate it produces identical normalization results to the originally released VBA implementation, and describe how it can be used.

bioinformatics↗

Ovarify: a generalizable deep learning method for the automatic characterization of ovarian morphology on pelvic ultrasonography

Ovarian morphology on ultrasonography is commonly used in the assessment of female reproductive health, such as in the diagnostic evaluation of polyendocrine metabolic ovarian syndrome (PMOS) and monitoring of response to assisted reproduction. Standard morphological markers quantified on pelvic ultrasound are ovarian volume (OV) and measures of antral follicle count (AFC) such as follicle number per slice or per ovary (FNPS, FNPO). Manual assessment of these features is operator-dependent, which limits the reliability of these measurements, impacting the delivery of consistent care. To address this, we have developed Ovarify, the first deep learning workflow to automatically characterize ovarian morphology from pelvic ultrasonography across multiple clinical contexts. Ovarify was trained on transvaginal ultrasonographic volumes garnered across three centers and evaluated on a held-out internal test set in addition to three external datasets spanning heterogeneity in image collection protocols, scanner hardware, and populations, across both single frames as well as whole-volumes. Ovarify segmented the ovary and follicles with high fidelity, outperforming U-Net and ResNet-34 baselines (p<0.001). Morphological measurements agreed closely with validated image analysis protocols on an internal test set (OV: Pearson r=0.892, FNPS: r=0.667, FNPO: r=0.770); across external datasets, workflow performance was similar. Ovarify additionally retained performance when evaluated on unseen images of ovaries undergoing controlled ovarian stimulation (FNPS: Pearson r=0.813). Ovarify-derived measurements classified polycystic ovarian morphology with an AUPRC of 0.90 (F1=0.93) using FNPO and 0.80 using OV. Ultimately, Ovarify provides a reproducible, operator-independent characterization of ovarian morphology directly from routinely-acquired pelvic ultrasonograms, generalizing across scanners, acquisition formats, and clinically-distinct imaging contexts. Ovarify automates the assessment of clinically-relevant morphological markers, allowing for the unbiased and consistent evaluation of morphological features.

bioinformatics↗

Recovering Missing Regulations by Multiplex Graph Aggregation of GRN Predictions (Technical Report)

Gene regulatory networks (GRNs) capture the complex gene interactions underlying biological systems. However, existing GRN inference models face technical challenges in recovering faithful GRNs from single-cell RNA sequencing data in an unsupervised setting. GRN aggregation has been proposed to leverage the wisdom of different GRN models and improve overall performance, but aggregation methods either train on ground-truth edges, overlook the network nature of GRNs, or are computationally expensive. To bridge this gap, we propose MuxGRN, a novel GRN aggregation method that leverages multiplex link prediction to aggregate GRNs inferred from various state-of-the-art models and extract the information propagated within different layers of GRNs. We use CompGCN for representation learning and the variational graph autoencoder framework for self-supervised link prediction, which does not require ground-truth labels and can capture GRN network structure efficiently. Under this formulation, MuxGRN aggregates GRNs inferred by 9 GRN models and is evaluated on 14 real single-cell RNA sequencing datasets against the individual models and two edge-level aggregation baselines. Our evaluation shows that MuxGRN recovers up to 26.55% of previously missed true-positive edges that individual GRN models miss, substantially exceeding edge-level baselines while maintaining AUPRC comparable to the best individual GRN models. This supports the importance of the network structure in GRN and the potential for link prediction in GRN aggregation.

bioinformatics↗