bioRxiv · 10.64898/2026.11.17.767132
PMRIPrep: automated preprocessing and quantification of DSC and DCE MRI
Abstract
While dynamic susceptibility contrast (DSC) MRI measures hemodynamics and dynamic contrast-enhanced (DCE) MRI characterizes vascular permeability, quantitative values from both modalities remain processing-dependent. We present PMRIPrep, a Brain Imaging Data Structure (BIDS) App for automated DSC and DCE preprocessing and quantification. PMRIPrep adapts to available acquisitions and metadata, integrates both modalities within a session, and supports four DSC deconvolution methods and four DCE pharmacokinetic models. In DSC simulations with 4% cerebral blood volume and signal-to-noise ratio 50, pooled median absolute cerebral blood flow error was 13-19% across methods. Median Ktrans bias remained [≤]2% across four model-matched DCE configurations over 0-10% noise. End-to-end OSIPI analyses yielded DCE accuracy and clinical test-retest repeatability scores of 0.85 and 0.85, respectively. Outputs follow BIDS-Derivatives conventions and include machine-readable provenance and visual quality-control reports. PMRIPrep is freely available as a containerized application.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Rulseh, A. M., Rajan, A., Curl, B., Mohan, S., Vymazal, J., Chawla, S.. 2026-11-25. PMRIPrep: automated preprocessing and quantification of DSC and DCE MRI. https://doi.org/10.64898/2026.11.17.767132. https://searchbiorxiv.org/record/biorxiv%3A10.64898%2F2026.11.17.767132/pmriprep-automated-preprocessing-and-quantification-of-dsc-and-dce-mri
Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search bioRxiv by Indiciae: BibTeX · RIS.