Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.10.29.762731

NeuroPack: Advanced Learnable Packaging Toolkit Towards Ultra-High Compression Ratio for Volumetric Neuroimaging

Abstract

High-throughput 3D microscopic imaging generates brain-volume datasets at terabyte to petabyte scale, posing significant storage challenges for large-scale neuroimaging data. In this study, we introduce NeuroPack, a hyperprior-driven 3D deep-learning-based packaging toolkit specifically designed for compressing 3D microscopic volumes at the mesoscale. NeuroPack encodes a compact hyperprior stream that conditions its entropy model on local voxel-wise variance, adaptively allocating bits to preserve mesoscale anatomical details for an optimal rate-distortion balance. To ensure reproducible deployment across heterogeneous microscopy datasets and computing environments, NeuroPack implements model integerization for the hyperprior side-information pathway, whose hyper-decoder predicts the Gaussian mean and scale parameters used by the arithmetic coder. By replacing platform-dependent floating-point hyper-decoding with deterministic fixed-point integer convolutions, NeuroPack produces bit-exact entropy models across CPUs, GPUs, local workstations, and cloud servers, thereby preventing decoding drift caused by floating-point rounding, fused-multiply-add ordering, or library-specific kernels. This integerized design preserves rate-distortion behavior while maintaining efficient encoding and decoding for large anisotropic 3D microscopy volumes. Our method enables high-fidelity microscopy reconstruction at 100- to 1000-fold compression across diverse modalities and species. Quantitatively, NeuroPack delivers the strongest overall rate-distortion performance in both BD-PSNR and BD-MSSSIM, with average relative gains of 73.4% and 50.8%, respectively, over the best competing codec. Importantly, NeuroPack preserves image fidelity required for downstream morphological reconstruction and analysis, as validated by simultaneous human annotation of original and decompressed confocal whole-brain zebrafish microscopy images. Together, NeuroPack provides a learning-based compression framework explicitly tailored for microscopy data, establishing a scalable storage solution for data-intensive neuroimaging and AI-empowered biological discovery.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zhao, R., Yang, X., Wu, J., Zheng, Q., Zhang, J., Guan, J.-Q., Cai, W., Du, J.-L., Bai, L., Du, X.-F., Ouyang, W., Lu, G., Song, C.. 2026-10-30. NeuroPack: Advanced Learnable Packaging Toolkit Towards Ultra-High Compression Ratio for Volumetric Neuroimaging. https://doi.org/10.64898/2026.10.29.762731

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Impaired loading following denervation elicits dynamic, differential growth trajectories of musculoskeletal tissues

Physical forces dictate the function and maintenance of adult musculoskeletal tissues. Yet, the impact of biophysical cues on the growth and maturation of these tissues, especially dense connective tissues, remains unclear. Here, we investigated the effects of neonatal mechanical loading on early postnatal growth of the musculoskeletal tissues of the lower limb, with particular focus on the Achilles tendon. We performed sciatic nerve resection (SNR) on one-day-old mice to denervate the hamstrings and distal hindlimb muscles. Sciatic Nerve Resection resulted in severe and sustained alterations in gait, accompanied by an altered transcriptional landscape in distal musculoskeletal tissues, with marked reductions in bone and tendon growth and smaller, fibrotic hindlimb musculature. Sciatic nerve resection impaired cumulative growth in the Achilles tendon, shifting cell proliferation and matrix-driven growth trajectories and altering mechanotransduction gene programs toward inflammation and matrix catabolism with age. This work highlights the essential role of mechanical loading in driving mechanosignaling and postnatal growth trajectories in musculoskeletal tissues of the developing limb, with implications for overall musculoskeletal health in adulthood.

bioengineering↗

MiniMAP: An automatic pipeline for paediatric lower limb musculoskeletal model generation

The generation of paediatric musculoskeletal models often requires compromise between data availability, accuracy, and computation time. Statistical shape models allow for rapid generation of bone geometries for use in musculoskeletal modelling. An articulated shape model allows for movement at the joints during optimisation to better fit to experimental data. Here we present a methodology for generating custom paediatric OpenSim models using an articulated shape model of the lower limb generated from CT scans of over 300 children aged 4 to 18 years old. Bone geometries are predicted using demographic factors (age, height, mass, and sex), linear bone measurements (bone widths and lengths), and 12 skin surface landmarks (L/R ASIS, L/R PSIS, medial/lateral epicondyles, and medial/lateral malleoli). To account for skin padding (bone to skin surface distance) a random forest algorithm was developed for skin padding prediction for these 12 landmarks. Accuracy of the model prediction was assessed using a leave-one-out analysis to assess landmark errors, bone surface errors, and clinical bone measurement errors (linear measurements and angular values). Motion capture and MRI data were collected from two paediatric test cases to test the workflow on unseen data. Skin padding values varied widely in this population with average values from 3.4mm at the lateral malleolus to 25.9mm at the PSIS. Skin padding was best predicted using age, height, mass, ASIS width, epicondylar width, and malleolar width with an average RMSE of 4.68mm. The articulated shape model predicted accurate bone geometries from skin surface landmarks with average bone surface RMSEs of 2.64 {+/-} 0.99mm, 1.91 {+/-} 0.59mm, and 1.69 {+/-} 0.56mm in the pelvis, femora, and tibiae/fibulae respectively. In the two unseen test cases, average bone surface errors ranged from 1.64 {+/-} 1.2mm to 3.41 {+/-} 3.1mm. This study demonstrated the accuracy of "MiniMAP", for the rapid generation of custom paediatric musculoskeletal models.

bioengineering↗

A single-plane electrical impedance tomography framework for integrated liver and kidney assessment

Chronic liver and kidney diseases frequently coexist, but their assessment typically requires separate clinical workflows involving serum-based estimated glomerular filtration rate (eGFR) testing and liver elastography-based controlled attenuation parameter (CAP). Electrical impedance tomography (EIT) has recently shown promise for providing portable, non-invasive proxies for both reference measurements. However, existing multi-organ EIT assessment still requires different acquisition protocols for each organ. To simplify this procedure, we assessed the feasibility of a single-plane EIT framework for reconstructing organ-specific images and estimating liver and kidney health from one abdominal belt placement. Across diverse abdominal belt locations, opposite-plane deviation was significantly greater for eGFREIT estimates (2.92%; IQR, 0.46-12.53%) than for CAPEIT estimates (0.94%; IQR, 0.66-1.70%) (p < 0.01). For both organs, compared to images acquired at the conventional organ-specific planes, image correlation significantly decreased (both, p < 0.05) and normalized root mean squared error significantly increased (both, p < 0.05) at the furthest imaging plane, with these differences being numerically larger for the kidney. Together, these results supported the kidney plane as the preferred location for multi-organ assessment. Test-retest evaluation after belt removal and reapplication demonstrated that the correlation between two repeated CAPEIT estimates was just as strong at the kidney plane (R2 = 0.98, p < 0.001) as it was at the conventional liver plane (R2 = 0.97, p < 0.001). Finally, in an independent clinical cohort, kidney-plane CAPEIT estimates were significantly higher in participants with a high metabolic liver-risk profile (i.e. diabetes and high blood pressure) (p < 0.005). CAPEIT estimates also distinguished high and low metabolic risk groups with an AUC of 0.756. Together, these findings support the feasibility of a portable multi-organ EIT imaging framework capable of extracting complementary liver and kidney information from a single belt placement.

bioengineering↗