Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.10.03.756481

Human Intestinal Absorption Revisited: The 1998 Descriptors Survive, and the Method Extends to Permeability

Abstract

In 1998 we predicted percent human intestinal absorption (HIA) for 86 drug and drug-like compounds from six molecular descriptors chosen by a genetic algorithm with a small neural network serving as the fitness function. That result rested on one division of the compounds into three sets: training, cross-validation and external prediction. Repeating the division shows it was a rather fortunate one. An extraction is one random draw from a wide distribution, so we repeat every experiment 250 times and report the result as a distribution. Across 250 stratified extractions, 14 match the published cross-validation error and only one matches the published external prediction error. Reconstructed this way, the published six descriptors give a mean extraction error roughly twice the external prediction value we reported in 1998 (Table 1). We then applied the same six descriptors to a larger set of 780 compounds from a public compilation. Under the 1998 network they give 22.50 %HIA units on training compounds against 25.77 on extracted compounds, whereas on the 86 they give 13.43 against 30.39. More compounds close the gap between fitting and prediction. Four datasets are modeled here: 780 small molecules with HIA measured in man, 3,771 small molecules and 1,281 cyclic peptides measured across Caco-2 cell monolayers, and 7,298 cyclic peptides measured across artificial membranes. Each is its own prediction problem, and one procedure is applied to all four. A genetic algorithm chooses which descriptors to use and how many, and a random forest grades each choice on compounds its own trees never saw. The descriptors chosen most often across the 250 extractions form one consensus set for each dataset. For absorption, 25 consensus descriptors under a random forest reach an extraction rms of 20.47 %HIA units at R 0.76. On the same compounds and the same extractions, the six 1998 descriptors under the 1998 network reach 25.77 at R 0.59. The four models are served at predicthia.ai, where a structure can be drawn or pasted, scored against its training set for similarity, and the training data with fitted models downloaded. Each model served is its fixed consensus set fitted on every compound in its dataset; the accuracy quoted beside a prediction comes from evaluating that same set across 250 extractions (Table 3). The fixed sets hold 25 descriptors for absorption, 55 for Caco-2 small-molecule permeability, 50 for Caco-2 peptide permeability and 25 for artificial-membrane permeability. Keywords: human intestinal absorption; QSPR; genetic algorithm; descriptor selection; cyclic peptides; membrane permeability; oral bioavailability; repeated extraction

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Muskal, S. M., Wessel, M. D.. 2026-10-11. Human Intestinal Absorption Revisited: The 1998 Descriptors Survive, and the Method Extends to Permeability. https://doi.org/10.64898/2026.10.03.756481

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Carrier-Limited Release Risk in Electrospun Nanofibers for Regenerative Endodontics: Constraint Discovery from 25 Formulations

Regenerative endodontics needs an intracanal carrier that keeps disinfecting across a dressing interval that clinicians schedule at one to four weeks, without harming the stem cells that rebuild the pulp. We ask what one completed 25-formulation electrospinning campaign of poly(vinylpyrrolidone) (PVP) fibers carrying metronidazole, ciprofloxacin, minocycline and Ca(OH)2 can decide, and use machine learning for constraint discovery and decision support rather than as a new predictor. After an audit against the source thesis, logistic regression predicts fine-fiber formation at 96% leave-one-out accuracy, but a one-threshold rule does as well, the gain over the 80% majority baseline is not significant (exact McNemar p = 0.125), and accuracy falls to 84% when mixture loading is encoded per component. Diameter models interpolate within formulation families (ridge MAE 193 nm, 95% CI 96 to 317 nm) and fail across them (R^2 < 0). Because the campaign never measured release, we assemble a same-drug, cross-carrier evidence table: 17 bounded metronidazole and ciprofloxacin observations from seven studies, with two-sided censoring. Water-soluble carriers (PVP, PVA) completed release within 80 h (PVP within 8 h); no water-insoluble monolithic carrier reached 90% within its observation window, releasing 1.5 to 50%; both within-study comparisons separate at matched loading; and blend, core-shell and thick-mat architectures released over 3 to 28 days. The PVP mats therefore carry a carrier-limited release risk, not a proven ceiling, and one dissolution experiment can confirm or overturn it. A censoring-aware screen keeps three necessarily and one possibly nondominated formulation, and fixed-budget replays show that uncertainty sampling finds failed formulations sooner, except the one it is confidently wrong about.

bioinformatics↗

CellMethMarker provides an integrated database of human cell- and tissue-type-specific DNA methylation markers

Cell- and tissue-type-specific DNA methylation markers provide epigenetic signatures of cellular identity and are widely used to infer cellular origin from bulk and single-cell methylomes. Existing resources mainly emphasize disease-associated biomarkers, methylome atlases, genomic annotations or RNA-based cell markers, leaving an unmet need for an integrated region-level resource dedicated to such markers. Here we present CellMethMarker (http://gu-zhanglab.hfcas.ac.cn/CellMethMarker), a curated database integrating 347,514 de novo markers derived from uniformly processed whole-genome and reduced-representation bisulfite sequencing datasets, 2,203,507 literature-derived marker records and harmonized metadata for 2,810 samples. CellMethMarker enables cell- and tissue-centered marker retrieval, coordinate-based search, genome-browser visualization, interactive methylation analysis and data download. In an independent single-cell methylome atlas, these markers recover the expected cell-type-associated methylation patterns, and a platform-matched reference built from them lowers the mean deconvolution error from 0.365 to 0.144. CellMethMarker therefore links region-level DNA methylation variation to cellular identity and supports methylome-based cell-type annotation and deconvolution.

bioinformatics↗

IG-28 enables identification and quantification of high-confidence isoforms from large bulk and single-cell full-length cDNA datasets

The technology to sequence full-length transcriptomes from bulk and single-cell samples has rapidly advanced. As a result, full-length cDNA datasets now reach billions of reads in size which is beyond the capability of most established isoform identification tools. Here, we introduce IG-28 which addresses this challenge with its capability to process and analyze large fl-cDNA datasets fast and using minimal computational resources. In contrast to its predecessor Mandalorion, IG-28 is not limited to bulk fl-cDNA but is capable of parsing, processing, and analyzing single-cell fl-cDNA datasets. It does so in a lightweight, flexible manner, integrating seamlessly with established scRNA-seq analysis workflows. We benchmarked IG-28 against a variety of established and new isoform identification tools using several bulk and a complex single-cell fl-cDNA dataset and found that IG-28 consistently outperformed the other tools by identifying high-confidence public isoforms.

bioinformatics↗