Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.09.08.749745

Specificity-driven protein binder design with Odin-Multi

Abstract

A useful protein binder is defined as much by what it does not bind as by what it does. Some applications call for one binder to cover a family of related targets; others require it to distinguish a single member from near-identical relatives. Yet, widely used deep-learning-based de novo design methods typically optimise one interaction at a time, leaving cross-reactivity and specificity to emerge during downstream screening. Here we present Odin-Multi, a binder design framework that optimises a shared binder sequence against several complexes simultaneously, applying attractive objectives to on-targets and repulsive objectives to off-targets. We benchmarked Odin-Multi in silico across three systems representing distinct cross-reactivity and specificity challenges: class B1 G protein-coupled receptors (GPCRs), testing cross-reactivity across multiple therapeutically relevant receptors; short-chain three-finger toxins, testing cross-reactivity across homologous toxin family members; and peptide-MHC (pMHC) complexes, testing specificity between near-identical target and off-target surfaces. For pairs of related class B1 GPCRs, 83.5 to 96.8% of jointly optimised designs exceeded an interaction-confidence threshold for both targets, compared with 6.8 to 36.3% of designs from single-target campaigns. For two short-chain three-finger neurotoxins, 9.2% of jointly optimised designs exceeded the corresponding threshold for both targets, compared with 0.8% of designs optimised against one toxin alone. Finally, in a pMHC specificity benchmark where target and off-target differed only in a single peptide residue, counter-selection increased the fraction of designs satisfying both the target-confidence criterion and a target-to-off-target interaction-confidence ratio of 2.5 from 6.0% to 14.2%. Experimental screening produced leads consistent with both design regimes in the two systems tested in vitro. We identified a cross-reactive toxin minibinder showing apparent nanomolar binding to the neurotoxin Erabutoxin A and to a candidate NK-shNTx-containing fraction from Naja kaouthia venom (higher-affinity fitted components of 11.95 and 34.43 nM, respectively), and a pMHC minibinder with greater target-to-off-target discrimination than a previously reported design. By treating cross-reactivity and specificity as explicit design objectives rather than screening outcomes, Odin-Multi widens the range of binding behaviours accessible to computational design.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Brasas, V., Christensen, C. R., Björnsson, K. H., Moller, V. E., Scapolo, B., Benard-Valle, M., Nygaard, M. M., Nielsen, J. C., Hadrup, S. R., Johansen, K. H., Jenkins, T. P.. 2026-09-09. Specificity-driven protein binder design with Odin-Multi. https://doi.org/10.64898/2026.09.08.749745

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗