Search bioRxivSearch

bioRxiv · 10.64898/2026.08.26.747367

Test-Retest Reliability of Motor Evoked Potentials Across Eight Bilateral Lower-Limb Muscles

Abstract

Objectives: Transcranial magnetic stimulation (TMS) is widely used to probe corticospinal excitability by eliciting motor evoked potential (MEP)s in targeted muscles, with MEP characteristics such as magnitude and latency reflecting the physiological state of the pathways being stimulated. Although numerous studies have examined MEP reliability in upper extremity muscles, less is known about the reliability of this measurement across the lower extremity. We hypothesized that inter-session, test-retest reliability of MEPs recorded simultaneously from multiple lower-limb muscles, from a single TMS location, would differ by muscle, stimulation intensity, and quantification method. Materials and Methods: Ten healthy participants (5 males, 5 females) completed three TMS sessions separated by atleast one week. At each session, the stimulation hotspot was identified using a five-location virtual grid anchored at the vertex, with electromyography (EMG) recorded from all eight muscles of interest at each grid location; the grid location producing the largest and most consistent MEPs in the tibialis anterior (TA), the primary target muscle, was selected as the stimulation site and held constant across all three sessions. MEPs were then recorded bilaterally from the TA, soleus, rectus femoris, and biceps femoris muscles at two stimulation intensities (110% and 120% resting motor threshold (RMT)). MEP size was quantified using mean rectified magnitude and peak-to-peak amplitude, and inter-session reliability was assessed using intraclass correlation coefficients (ICC). Bland-Altman analysis was used to characterize the range of measurement variability across all eight muscles. Results: MEP size differed across sessions, and reliability varied by muscle, intensity, and quantification method. The highest reliability was observed in the right TA, the muscle used to establish the stimulation hotspot, using mean rectified magnitude at 120% RMT. Reliability was comparatively lower in the seven non-target muscles recorded from the same fixed stimulation site, indicating that MEP consistency was not uniform across the lower-limb musculature. Conclusions: MEP reliability in the lower extremity depends heavily on the muscle, stimulation intensity, and quantification method used, and is highest in the muscle for which the stimulation site was optimized. These findings support the interpretation that coil positioning targeted to a specific muscle yields more consistent responses in that muscle than in others recorded from the same fixed site, and underscore the importance of careful muscle selection and hotspot optimization when designing TMS protocols for longitudinal or clinical lower-limb research.

Explore related subjects

Keep this discovery

BibTeXRIS

Willson, K., mojtabavi, h., Wolpaw, J. R., Hardesty, R. L.. 2026-09-01. Test-Retest Reliability of Motor Evoked Potentials Across Eight Bilateral Lower-Limb Muscles. https://doi.org/10.64898/2026.08.26.747367

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related discoveries

Evolution and Human Neural Individuality

Individuality is a defining feature of human biology. The functional network architecture of the human brain harbors person-specific qualities and forms individualized connectivity profiles that function as a neural fingerprint, both stable and unique across time. Here, using fMRI data from 431 Human Connectome Project participants, we examined whether neural individuality is more strongly exhibited in brain regions bearing signatures of recent human evolution. We calculated region-wise fingerprinting accuracy and associated it with four properties of evolutionary cortical organization: cortical expansion, myelin content estimate (T1w/T2w), human-specific gene-expression profiles, and functional homology to other primates. Across all four measures, neural individuality was strongest in cortical areas showing greater evolutionary novelty in humans, particularly frontoparietal control and default mode networks, and weaker in more conserved primary regions. Our findings connect evolutionary variation across species with stable functional variation among individuals.

neuroscience

Motor planning and execution establish distinct feedforward and feedback motor histories

Movements are systematically affected by the recent motor history. These history effects may be induced either by reused motor plans or from lingering tuning of the previous movements' execution. We dissociated planning and execution using four experimental manipulations across two complementary motor paradigms. We isolated planning by preventing execution with stop signals and mechanical blocks, and execution by moving participants' hand passively using a robot manipulandum. History effects emerged in feedforward movement aspects - reaction time and early movement kinematics - following isolated planning. In contrast, they were absent or markedly reduced for isolated execution. History effects emerged also in late movement aspect that involves sensory feedback during execution - movement accuracy and precision - but only when movements were both planned and executed. Feedforward effects generalized across hands, whereas feedback effects were effector specific. Thus, prior motor planning and execution make distinct and complementary contributions in shaping future motor behavior.

neuroscience

Hypothermic Conditions Impair GnRH Pulse Generator Activity and Gametogenesis

Mammalian reproductive function is driven by arcuate kisspeptin neurons, pacemakers of gonadotropin secretion. During energy shortages, animals reallocate resources from reproduction to survival; however, the underlying neural mechanisms remain elusive. Here we used fiber photometry to chronically monitor synchronized episodes of arcuate kisspeptin neuron activity (SEskiss) in adult mice under various energy-saving conditions. In both sexes, SEskiss frequency was markedly suppressed during fasting-induced torpor and pharmacologically induced hypothermia, whereas hypometabolism alone had no discernible effect. A Q neuron-induced hypothermic state (QIH) robustly suppressed SEskiss, leading to impaired gamete maturation, whereas warming the body temperature during QIH fully restored SEskiss frequency. These findings demonstrate that hypothermia, rather than hypometabolism, is the primary driver of suppression of the hypothalamic reproductive axis during energy-saving conditions. This study provides insights into how thermal signals act as critical gatekeepers in the mammalian reproductive system.

neuroscience