Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.07.13.738140

Prediction-Guided Design of a More Developable FGF21 Construct

Abstract

For structural-biology and protein-production pipelines, the hardest part of a difficult protein is not the biology -- it is obtaining a well-behaved sample for functional studies. Programs routinely stall at construct design, expression, and purification: deciding where to truncate, which tags to use, how to express, and how to purify so the protein survives concentration and handling. These decisions are still made largely by literature precedent and experimental experience, and they require trial-and-error before arriving at a functional construct for hard targets. We present a prospective, single-pair wet-lab case study testing whether an integrated computational platform can improve these decisions. For human fibroblast growth factor 21 (FGF21) -- a clinically important and stability-challenged metabolic hormone -- we compared two expression constructs produced side by side under the same experimental workflow, using two different design strategies: one designed by a scientist from the literature (reproducing the published core-domain construct, PDB 6M6E), and one designed by the Orbion platform -- an AI, prediction-guided protein-design system (orbion.life) -- which additionally generated the expression and purification protocols (executed scientist-in-the-loop). The platforms construct used an unconventional, longer C-terminal boundary not found in public sequence databases. Since the two constructs differ in more than one feature, we treat them as workflow-level designs throughout. The scientist construct gave a higher initial yield ([~]2.4 xmore protein recovered at affinity capture). The platform-designed construct, however, showed a more favourable downstream developability profile: it concentrated higher (1.4 vs 0.7 mg/mL) while remaining more monodisperse by dynamic light scattering (DLS). The scientist construct, in contrast, aggregated on concentration, so its initial-yield advantage did not survive: in the final concentrated sample the Orbion construct provided the more usable material for downstream studies. Computed for the mammalian host used, the platform had prospectively scored its own design higher (composite 68.7 vs 59.0 for the scientist-designed construct), and its predictions of yield, solubility, and disorder matched the wet-lab outcome. This is a single, deliberately scoped case study, not a population-level benchmark; the two constructs differ in more than one feature, and biological activity was not assayed. Alongside the bottlenecks of this approach discussed here, used as a decision aid, prediction-guided construct and protocol design has the potential to remove costly iteration cycles of protein production campaigns.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bozkurt, C., Nathanail, E., Goteti, A.. 2026-07-14. Prediction-Guided Design of a More Developable FGF21 Construct. https://doi.org/10.64898/2026.07.13.738140

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗