Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.07.09.737574

LYNX: a deep generative model for linking spatial dynamics and cellinteractions in multimodal spatial data

Abstract

Tissues are spatially organized systems in which cell states, functions and interactions vary across spatial coordinates, forming compartments or gradients shaped by local microenvironments. Understanding how molecular features and cell-cell interactions change across space and time is central to studying development, homeostasis and disease. Addressing these questions increasingly requires the integration of multi-modal spatial data, which provides complementary views of cellular and structural organization. However, existing computational approaches typically combine modalities by weighting them equally, overlooking domain-specific technical artifacts, differences in spatial resolution and non-overlapping feature spaces. In addition, methods for spatial cell-cell communication analysis are largely developed for single-modality settings and do not model how interactions vary across the tissue. To address these gaps, we introduce LYNX, a deep generative framework that learns a shared latent representation of spatial dynamics from joint-measured modalities in the 2D or 3D domain, to provide a unified coordinate system for modeling how cell-cell interactions, phenotypes, and molecular programs vary along continuous spatial gradients. LYNX identifies spatial programs difficult to resolve with existing approaches, including metabolically coupled porto-central interaction remodeling in liver, recovery of degraded proteomic signals along the cortico-medullary axis in thymus, and branching trajectories towards DCIS and invasive niches marked by distinct stromal activation-states and immune-tumor crosstalk in breast tumor microenvironment. We demonstrate that LYNX robustly infers spatially resolved gradients, maps functional compartments and cell-cell interactions along spatial axes and is compatible across diverse spatial profiling technologies, modalities, and resolution disparities. LYNX provides a foundational and scalable framework to advance our understanding of healthy tissue physiology and to decode temporal evolution of complex diseases.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jin, Y., Myers, J., Rajbhandari, P., Zhang, J. Y., Fang, K., Moazami, J. S., Hosny, N., Stockwell, B., Azizi, E.. 2026-07-10. LYNX: a deep generative model for linking spatial dynamics and cellinteractions in multimodal spatial data. https://doi.org/10.64898/2026.07.09.737574

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗