Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.06.30.735496

Smartphone-Validated Portable Paper-Based Device Integrated with an Electropolymerized Molecularly Imprinted Polymer for Serotonin Detection in Serum Samples

Abstract

Accurate and decentralized quantification of serotonin, also known as 5-hydroxytryptamine (5-HT), in biological fluids is critically important for the diagnosis, prognosis, and therapeutic monitoring of neurological and psychiatric disorders. However, conventional analytical methods generally rely on centralized laboratory infrastructure, skilled personnel, and labor-intensive sample processing, which restrict their applicability in rapid near-patient and point-of-care settings. Herein, we report a portable molecularly imprinted polymer (MIP)-based electrochemical sensing platform for selective and on-site detection of serotonin using screen-printed carbon electrodes (SPCEs). The biomimetic recognition interface was fabricated through direct electropolymerization of a polydopamine recognition layer in the presence of serotonin as the template molecule, followed by template extraction to generate complementary recognition cavities for selective rebinding. The sensor fabrication parameters, including monomer concentration, electropolymerization cycles, template-to-monomer stoichiometry, and electrolyte pH, were systematically optimized to achieve improved sensitivity, selectivity, and signal stability. Under optimized conditions, the MIP/SPCE sensor exhibited a broad linear response from 10 pM -10 {micro}M in phosphate buffer, with a correlation coefficient of R2 = 0.974 and an ultralow limit of detection of 0.16 pM. The analytical applicability of the platform was further validated in spiked artificial serum, where the sensor achieved an LOD of 0.12 pM, satisfactory recovery values of 88.66-96.02%, and acceptable precision with RSD values [≤] 8.43% (n=3), confirming its reliability in a complex biological matrix. The developed sensor demonstrated excellent selectivity toward serotonin against physiologically relevant interferents, maintaining signal retention between 99% and 101%. In addition, the platform showed high operational repeatability with an RSD of 0.45%, good inter-electrode reproducibility with an RSD of 6.3%, and long-term storage stability, retaining 90-110% of its initial response over 28 days. Importantly, cross-platform validation using a smartphone-coupled potentiostat demonstrated strong analytical agreement with laboratory-grade instrumentation, as evidenced by R2 = 0.9967 and a slope of 1.023. These findings establish the proposed MIP/SPCE platform as a simple, low-cost, portable, and smartphone-compatible electrochemical device for field-deployable serotonin monitoring in clinically relevant samples.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Borasi, H., Parmar, B., Agarwal, P., Bhatia, D. D., Yadav, A. K.. 2026-07-01. Smartphone-Validated Portable Paper-Based Device Integrated with an Electropolymerized Molecularly Imprinted Polymer for Serotonin Detection in Serum Samples. https://doi.org/10.64898/2026.06.30.735496

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗