Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.06.22.733686

Engineering an in vitro spinal column: Manufacturing designs and emerging solutions for producing an axial mechanobiological system

Abstract

The human spine is a complex, coordinated biomechanical system. Physiologically, its tissues are also highly interdependent in terms of function and viability. The interaction between mechanical stress and biological/biochemical activity over time constitutes a key driver of spinal degeneration. Research to date providing mechanistic insights into this process has focused on individual components (vertebra and disc tissue analogues), in isolation or as basic functional units. However, many observations from individual units will not translate to whole spine behaviour. The intricate complexity of the spine requires novel experimental models (synthetic and biotic), which must consider the spine at an organ level and adopt an integrative approach that can capture the dynamics which govern its function. Here, we report the development of a biomimetic spinal model prototype, amenable to cellular integration, which is miniaturised to the in vitro scale to provide a controlled environment and testbed for axial biological mechanics. The research presented here encompasses more than a decade of systematic investigations during which the gradual emergence of key manufacturing innovations progressively enabled addressing an exceptionally complex bioengineering challenge - organotypic spine engineering. The model comprises the full anatomical range of spinal vertebrae/bones (C1 to Sacrum & Coccyx), reproduced using bioceramic materials, assembled in sequence into a relevant columnar architecture and mechanically connected end-to-end by biochemically active interfaces. A range of assessments examining anatomical design, material behaviour and manufacturing processes is presented. The work explores concepts such as longitudinal mechanobiology and multi-segment coupling as well as manufacturing strategies using autonomous materials and instrumentation. This prototype introduces for the first time columnar level behaviour and the ability to study time dependent adaptations. This model is important because it can support tissue maturation, evolving mechanical properties and adaptive behaviour and it represents an intermediate step between isolated skeletal tissue models and future organ-level spinal constructs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Iordachescu, A., Vigneswaran, R., Atanasov, A., Grover, L. M., Metcalfe, A. D., Cendrowicz, A.. 2026-06-23. Engineering an in vitro spinal column: Manufacturing designs and emerging solutions for producing an axial mechanobiological system. https://doi.org/10.64898/2026.06.22.733686

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗