Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.06.14.732127

Selectivity of Lateral Epidural Spinal Cord Stimulation with Varying Electrode Diameters and Stimulation Configurations

Abstract

Objective. Our prior studies have demonstrated that lateral spinal cord stimulation can evoke somatosensory percepts in the missing foot in individuals with a lower-limb amputation. However, subjects reported concurrent sensations in their residual limb. In this study, we evaluate the hypothesis that using high-density paddle electrodes with smaller contact sizes, and multipolar stimulation configurations could evoke more focal sensations in the foot over a wide range of stimulation amplitudes. Approach. We used a combination of electrophysiology and computational modelling methods to investigate the selective activation of distal nerve branches in response to lateral spinal cord stimulation in cats. In six acute feline experiments, we performed an L3-S1 laminectomy and placed custom 32-electrode paddles laterally over the dura of the spinal cord. We recorded antidromic action potentials in the distal branches of the sciatic and femoral nerve trunks in response to stimulation using three contact diameters (150, 500 and 1000 {micro}m) and two stimulation configurations - monopolar and bipolar stimulation. We replicated the neural recruitment patterns from those experiments in a computational model of the feline lumbar spinal cord. We then used the model to examine neural recruitment with 1.8 mm and 2.5 mm contacts, as well as a tripolar guarded-cathode configuration. Main results. In the electrophysiology experiments, the 500 {micro}m-diameter electrodes achieved the most selective nerve activation (68%) compared to 62% for both 150 and 1000 {micro}m-diameter electrodes. The minimum amplitudes for recruiting nerve branches (i.e., threshold) as well as the dynamic ranges were largely similar for the different contact diameters (median: 35 {micro}A) and stimulation configurations (30 {micro}A for bipolar stimulation; 35 {micro}A for monopolar stimulation). The computational model reproduced the finding that selectivity did not differ significantly among the three contact sizes tested in cat experiments, though it revealed that increasing contact diameter above 1000 {micro}m raised the minimum amplitude required for selective activation and reduced spinal root selectivity. Across both approaches, we consistently recruited large-diameter afferents that are critical for somatosensory applications of spinal cord stimulation. Significance. Our results indicate that, relative to clinical electrodes, reducing the contact diameter of stimulation electrodes can evoke focal sensations, but further reductions below 1000 {micro}m may fail to improve selectivity. This study highlights potential constraints with achieving focal selectivity that are not dependent on the design of the electrodes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ansah, G. J., Del Brocco, M., Bhowmick, S., Duran, M. A., Gopinath, C. H., Jantz, M. K., Lempka, S. F., Fisher, L.. 2026-06-17. Selectivity of Lateral Epidural Spinal Cord Stimulation with Varying Electrode Diameters and Stimulation Configurations. https://doi.org/10.64898/2026.06.14.732127

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Single-Component Photo-Crosslinked Lipoic Acid Functionalized Mucin Hydrogels: Dynamic Mucus Mimetics for Antiviral Protection

Native mucus protects epithelial surfaces through viscoelastic networks of disulfide-linked mucins. However, commercially available mucins often fail to reconstitute comparable mechanical and barrier properties, while synthetic and hybrid mucus mimetics require polymeric crosslinkers that may alter mucus-like composition. Inspired by the native architecture, we directly functionalized porcine gastric and bovine submaxillary mucins with -lipoic acid to develop a single-component, photo-crosslinkable hydrogels. Upon UV irradiation (365 nm), the modified mucins rapidly form disulfide-crosslinked networks without added photo-initiator/ polymeric crosslinkers, two orders of magnitude faster as compared with PEG-SH approaches. The resulting mucin-lipoic acid (MUC-LA) hydrogels exhibit mucus-relevant properties, including tunable viscoelasticity, redox responsiveness, self-healing, and size-dependent restrictions on nanoparticle transport. In transwell-based infection models, MUC-LA hydrogels (2-3%) mimicking the healthy airway mucus (G' {approx} 10-20 Pa) suppress epithelial infection by SARS-CoV-2 and influenza A virus. Crosslinked MUC-LA provides greater protection against SARS-CoV-2 than the non-crosslinked, whereas both formulations suppress influenza A infection, suggesting distinct contributions from network formation and mucin-associated interactions. These findings establish a dynamic, mucus-mimetic platform integrating rapid photo-gelation, controllable mechanics, selective transport, and antiviral barrier functionality. MUC-LA hydrogels offer opportunities to investigate mucosal transport and host-pathogen interactions, with potential applications in drug delivery, and as biomaterials.

bioengineering↗

Population-level emulation enables fast Bayesian calibration of cardiac digital twins

Purpose: Patient-specific cardiac digital twins have the potential to guide individualized therapy, but generating these in a routine clinical workflow remains challenging. This is especially true when the twins must carry quantified uncertainty: Bayesian calibration requires thousands of simulations per patient, and the emulators that reduce this cost are typically trained one patient at a time. We aimed to train a single emulator across a patient cohort, so that a new patient can be calibrated in minutes without new simulations. Methods: We trained a population-level Gaussian process emulator whose inputs included a 12-dimensional latent encoding of the clinical features of each patient, so that a single emulator represents the whole cohort. We compared spending simulation budgets on resampling the real cohort with augmenting the cohort with digital chimeras, synthetic patients interpolated between real patients. Seven parameters of a closed-loop heart and circulation model were calibrated by Markov chain Monte Carlo to ten clinical biomarkers in 26 patients with left bundle branch block, each using an emulator trained without that patient, and the calibrated posteriors were compared against the full simulator. Results: A single emulator, trained without the held-out patient, calibrated the digital twin of each patient in 59.7-63.0 s per patient, versus 15 h with the simulator. Resampling the real cohort was the more efficient training strategy, bringing every output to R2 greater than or equal to 0.9, which augmentation did not achieve for the same simulation budget. For held-out patients, both strategies performed comparably (median leave-one-out normalized root-mean-square error 11.0% vs. 10.7%; p = 0.745), and error rose with distance from the cohort centroid (Spearman rho = +0.406). The calibrated models showed no cohort-wide bias (median standardized residual -0.12 against the clinical targets), and 95% predictive intervals contained 78.5% of targets, with the largest misfit in systolic blood pressure. Conclusion: Removing the need for new simulations for every new patient is a meaningful step toward uncertainty-aware cardiac digital twins that fit within a routine clinical workflow. Because the simulator, surrogate and sampler are interchangeable, the approach used here can be applied to other (cardiac) models and cohorts.

bioengineering↗

Multi-Structure Segmentation of Type B Aortic Dissection from CT Images with U-Net

Type B aortic dissection (TBAD) is a life-threatening condition in which a tear in the intimal layer separates the aortic wall into a true and a false lumen. Assessment of the lumen, the intimal flap, and false-lumen thrombosis from CT images is important for risk analysis and treatment planning. This work applied U-Net-based deep neural networks to the automatic segmentation of these structures in TBAD. We collected 46 CT scans from 20 patients, with voxel-wise annotations of three structures: the aortic lumen, the intimal flap, and the thrombus. We explored four models: two convolutional networks, nnU-Net 2D and 3D, and two transformer-based architectures, TransUNet 2D and 3D. We observed that (1) for both nnU-Net and TransUNet, the 3D models outperformed their 2D counterparts on all three structures. The difference was small for the aortic lumen but large for the thin flap and the thrombus. The best model, nnU-Net 3D, reached a DSC of 93.05% for the lumen, 50.22% for the flap, and 69.94% for the thrombus. (2) The intimal flap was the most difficult structure for all models. Even the best 3D models showed large thrombus boundary errors in a few scans. These results provide a baseline for developing more advanced models for accurate segmentation of these structures in TBAD.

bioengineering↗