Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.05.31.729042

Shape, Shrink, Spheroid: A DIY High-throughput Spheroid Generation Device

Abstract

3D spheroids, which closely replicate three-dimensional cell-cell and cell-extracellular matrix interactions, offer superior predictive capabilities compared to conventional 2D monolayer cultures, positioning them as forward-looking platforms in drug testing, cancer biology, and regenerative medicine. However, high-throughput generation of uniform sized spheroids is still a technological challenge. In one hand, the use of conventional ultra-low attachment (ULA) multiwell plates for this purpose is labour intensive and complex. On the other hand, the use of microfabricated facilities demands cutting-edge infrastructure such as clean room, photolithography, and microfluidic setup which are often unavailable for the resource constrained laboratories. In this study, we addressed these problems by developing a low-cost Do-It-Yourself (DIY), polydimethylsiloxane (PDMS) and agarose-based spheroid generation device, capable of producing and maintaining hundreds of spheroids with minimal user intervention. We have demonstrated two variants based on their size, termed here as S1 and S2 devices which fit into 6-well and 12-well plates, and can generate 600 and 1200 uniform-sized spheroids respectively. We validated our device with various cell lines including primary and cancerous cell lines. We further demonstrated the drug testing capabilities of the device by estimating the IC50 value of the anticancer drug Temozolomide on U87-MG. The value was comparable with the same obtained from the spheroids generated using conventional ULA plates. Additional attachment of a perfusion system made the device suitable for long-term spheroid culture without much user intervention. Furthermore, the devices can also be used for the production of spheroids with gradually changing diameters in a controlled manner, resembling a size gradient. This feature is useful for checking the effect of drugs on different-sized spheroids and for co-culturing spheroids with varying cell densities, mimicking the disease architecture. We have co-cultured two types of the placental trophoblast cells, i.e., extravillous trophoblast (HTR-8) and syncytiotrophoblast (BeWo) with varying densities. In summary, this paper demonstrates a unique DIY method for a high-throughput uniform-sized spheroid generation at a fraction of cost which can be deployed to resource-constrained labs.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mogha, P., Mukherjee, S., Gangwar, T., Roy, D., Vichare, A., Kulkarni, S., Sharma, V., Majumder, A.. 2026-06-03. Shape, Shrink, Spheroid: A DIY High-throughput Spheroid Generation Device. https://doi.org/10.64898/2026.05.31.729042

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Synergy-informed bilevel optimization reveals joint-specific benefits for realistic exoskeleton torque prediction

Simulation-driven optimization can guide exoskeleton control design, but its utility is limited by the accuracy with which muscle coordination is predicted. Strict effort-minimization formulations predict non-physiological muscle shutdown under high exoskeleton assistance, leading to peak assistive torques that exceed values reported in human-in-the-loop experiments. We evaluated the accuracy of synergy-informed simulations at predicting assistance across four single-joint exoskeleton configurations: ankle plantarflexion, knee extension, hip flexion, and hip abduction. We implemented a bilevel optimization to predict a parameterized assistive torque that minimizes metabolic cost, with assisted muscle dynamics estimated via either effort-minimization simulations (minimizing muscle effort only) or synergy-informed simulations (minimizing muscle effort constrained to a synergy structure). We used experimental data from five unimpaired adults walking at their preferred speed and compared results descriptively between the two formulations within each subject. Assistance based on effort-minimization simulations shut down agonist muscle activations and overestimated peak assistive torque compared with experimental values. In contrast, constraining muscle controls to a synergy structure prevented non-physiological muscle shutdown and yielded assistive torques closer to those measured in human-in-the-loop experiments. This benefit was not observed equally across all assisted degrees of freedom or subjects, emerging only where no single synergy could be suppressed to unload the assisted muscles. Synergy weights can therefore be interpreted as joint-specific predictors of when simulations can reliably inform wearable robot design.

bioengineering↗

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗