Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.05.28.728583

Single Particle Adsorption and Response Quantification for Functional AAVx Titer and Dose Analysis

Abstract

Accurate quantification of functional adeno-associated virus (AAV) dose remains a critical limitation in gene therapy, where titers are defined using ensemble measurements of viral genomes or capsid concentration that average across heterogeneous populations and weakly predict transduction. We present single-particle adsorption and response quantification (SPARQ), a diffraction-limited imaging platform for quantifying AAVx vectors, regardless of serotype, at single-nanoparticle and single-cell resolution. SPARQ immobilizes and resolves individual AAVx, enabling concurrent measurement of capsid-associated and genome-associated signals before cell exposure. Across multiple serotypes, including AAV2, AAV5, and AAVrh74, SPARQ identifies full-capsid fractions, consistent with bulk measurements obtained by ddPCR/ELISA, DLS/UV-Vis, charge detection, and mass photometry, while reporting narrower distributions than ensemble-derived values and revealing systematic discrepancies in bulk-derived titers arising from population averaging. Surface immobilization is achieved by charge-dependent AAVx-surface interactions, as supported by multiphysics simulations, which capture serotype-dependent adsorption kinetics governed by capsid electrostatics for AAV2, AAV5, AAV6, and AAV9. Furthermore, SPARQ directly measures transduction as a function of particle number and reveals a threshold response. Transduction efficiency increased from [~]29% (S.D {+/-} 3.31%) at [~]18 (S.D {+/-} 7.55) AAVs per cell to [~]66% (S.D {+/-} 1.66%) at [~]42 (S.D {+/-} 9.69) AAVs per cell, which is comparable with conventional in vitro assay requiring 105 AAVs/cell. Cumulative fluorescence measurements across large micro-patterned arrays of single cells recapitulate bulk-like high-throughput scaling, while SPARQs single-nanoparticle resolution reveals functional heterogeneity that is masked by population averaged assays. SPARQ provides a particle-resolved framework for functional AAVx titration and quantitative characterization, enabling the development of quality control and dosing strategies in gene therapy manufacturing. TeaserSPARQ combines light-activated surface viral adsorption with diffraction-limited imaging to directly quantify AAV integrity, heterogeneity, and functional transduction at the single-particle level.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Koratagere Nagaraj, C., Nugyen, T. K., Kwak, K. J., Bayazit, B., huang, X., Newell, J., doon-ralls, J., Rima, X. Y., Harper, S. Q., Saad, N. Y., Reategui, E.. 2026-05-29. Single Particle Adsorption and Response Quantification for Functional AAVx Titer and Dose Analysis. https://doi.org/10.64898/2026.05.28.728583

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗