Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.05.19.726391

Long-Lasting Electrohydrodynamically Printed Transparent Soft Microelectrode for Implantable Biointerfaces

Abstract

Reliable and scalable soft implantable neural interface fabrication remains a key challenge for chronic bioelectronic applications. Here, we present a transparent soft microelectrode fabricated with electrohydrodynamic (EHD) printing, utilizing the fluorinated polymer poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) and poly (3, 4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT: PSS) to form seamless, selectively patterned multilayer structures with low impedance and long-term stability. Controlled in situ curing during printing yields dense, void-free substrate and encapsulation layers, suppressing interfacial defects and ionic pathways, while maintaining high optical transparency (>60%) with PEDOT:PSS. The printed microelectrodes exhibit low impedance, high charge storage and injection capacities, and stable electrochemical behavior under biomimetic conditions. In addition, the devices demonstrate robust mechanical and electromechanical stability under cyclic deformation in both dry and wet environments, as well as under prolonged electrical stimulation. Accelerated aging studies project multi-year operational lifetimes, and in vitro/in vivo biocompatibility assessments confirm excellent tissue integration. These results establish EHD-printed fluorinated polymer-based microelectrodes as a scalable and durable platform for chronic implantable biointerfaces. ToC O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=182 SRC="FIGDIR/small/726391v1_ufig1.gif" ALT="Figure 1"> View larger version (79K): org.highwire.dtl.DTLVardef@f4f717org.highwire.dtl.DTLVardef@8a34a1org.highwire.dtl.DTLVardef@185540dorg.highwire.dtl.DTLVardef@51462a_HPS_FORMAT_FIGEXP M_FIG C_FIG This report presents an electrohydrodynamically printed transparent soft microelectrode for chronic purposes. Electrohydrodynamic printing promotes seamless multilayer structures with selective deposition and long-term mechanical stability. The devices show low impedance, high charge capacity, and robust electrochemical/electromechanical properties. Accelerated aging projects [~]7.2 year lifetimes, and XPS/SEM-EDS confirm strong ion barrier properties and biocompatibility for chronic implantation.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jo, H., Lee, G., Song, Y., Kim, S. Y., Kim, M., Manna, R., Choi, D., Aderibigbe, A., Suib, S. L., Park, K., Ahn, J., Song, J.-H., Kim, K.. 2026-05-21. Long-Lasting Electrohydrodynamically Printed Transparent Soft Microelectrode for Implantable Biointerfaces. https://doi.org/10.64898/2026.05.19.726391

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗