Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.05.06.723258

Engineering a hybrid 3D construct for bone regeneration to promote simultaneous pre-vascularization and osteogenic differentiation in vitro

Abstract

Critical-sized bone defects represent a challenge in bone tissue engineering, due to insufficient vascularization that results in implant failure. Scaffold pre-vascularization is a promising strategy to create a functional microvascular network that integrates with host vasculature. In this study, we present a hybrid 3D construct comprising a hyaluronic acid-based hydrogel and a 3D printed polycaprolactone/{beta}-tricalcium phosphate scaffold, to support vascular network formation and osteogenic differentiation. Peptide-functionalized (i.e. RGD, YIGSR, IKVAV, QK) hydrogels were obtained via thiol-ene chemistry, using two crosslinkers (PEG-diSH or MMP-diSH). Preliminary biological experiments assessed human mesenchymal stromal cells (hMSCs), endothelial cells (hUVECs), and their co-culture, on different gel formulations. All cell conditions displayed enhanced spreading and metabolic activity on gel formulations comprising RGD; thus these (i.e. RGD only and a combination of RGD/YIGSR) were selected for further studies. Cells were then mixed with the hydrogel precursor solutions, which were injected to embed the scaffolds and crosslinked using a UV lamp. After 7 days, tubule formation was observed only in co-culture conditions, highlighting the importance of cellular crosstalk for the formation of a vascular network. Significant differences were found across the tested formulations. In the RGD-PEG constructs, hUVECs formed tubule-like structures, surrounded by hMSCs, exhibiting pericyte-like behavior, supported by the upregulation of SMA gene. Conversely, in the RGD/YIGSR-MMP conditions, hMSCs were mostly located on the scaffold fibers, and showed the highest expression of early osteogenic markers (RUNX2 and ALP). Overall, we demonstrated that the hybrid system with tailored hydrogel chemistry can support simultaneous microvascular organization and osteogenic commitment, offering a promising platform for bone tissue engineering applications. However, further studies involving longer culture periods will aim at clarifying the complex interplay between material composition, cell crosstalk and spatial organization and their influence on the maturation and stability of the vascular network.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dalfino, S., Fagiolino, S., Beeren, I., Borrone, M., Alviano, F., Mota, C., Tartaglia, G., Dolci, C., Moroni, L.. 2026-05-09. Engineering a hybrid 3D construct for bone regeneration to promote simultaneous pre-vascularization and osteogenic differentiation in vitro. https://doi.org/10.64898/2026.05.06.723258

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗