Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.04.30.722037

Development of a Polyelectrolyte Complex Scaffold and its specific cell seeding method as a tool for liquid cancers drug screening

Abstract

This study focuses on the development of 3D culture model dedicated to liquid cancers drug screening. The challenge addressed was to effectively retain non adherent small cells within a 3D-scaffold with tailorable mechanical properties, while proposing a fast and effective tool for drug screening. To that aim, we developed a macroporous alginate-chitosan polyelectrolyte complex (PEC) scaffold combined with a low-viscosity alginate (LVA) cell seeding solution. We hypothesized that LVA could undergo in situ pore gelation via calcium ions retained from the PEC fabrication process, enabling effective retention and homogeneous cell distribution, leading to an improved platform for drug screening and personalized medicine. First, we evaluated scaffold suitability for LVA infiltration and gelation. Microtomography revealed a highly porous architecture (98%) enabling LVA homogeneous penetration and complete gelation within 30 min, as confirmed by SEM, microscopy, rheology, and micro-rheology. Next, we assessed cell retention and biocompatibility using primary human chronic lymphocytic leukemia (CLL) cells. LVA-assisted seeding increased cell density 2.6-fold compared to medium alone, with homogeneous distribution, >80% viability over 7 days, and preserved differentiation into nurse-like cells. Finally, we demonstrated a proof of concept for drug screening. The Alginate-PEC scaffold (A-PEC scaffold) supported both qualitative live/dead imaging and rapid quantitative viability measurement with the Alamar Blue assay. Drug responses reproduced microenvironment-dependent protection effects observed in vivo. This integrated scaffold and seeding method provides a promising 3D platform for in vitro liquid cancer studies and drug screening on patient-derived hematological cancer cells. Graphical abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=67 SRC="FIGDIR/small/722037v1_ufig1.gif" ALT="Figure 1"> View larger version (38K): org.highwire.dtl.DTLVardef@9b71d4org.highwire.dtl.DTLVardef@14e1dd0org.highwire.dtl.DTLVardef@1876a56org.highwire.dtl.DTLVardef@15656bc_HPS_FORMAT_FIGEXP M_FIG C_FIG

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Grossemy, S. E., Cadot, S., Farno, M., Cavalie, S., Sallerin, B., Ysebaert, L., Quillet-Mary, A., Girod Fullana, S.. 2026-05-05. Development of a Polyelectrolyte Complex Scaffold and its specific cell seeding method as a tool for liquid cancers drug screening. https://doi.org/10.64898/2026.04.30.722037

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗