Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.04.23.720335

An Expert-Informed Synthetic Animal Data Generator: A Physiology-Consistent Generative Framework for High-Fidelity Animal Digital Twins

Abstract

Digital twins are increasingly recognized as a transformative technology for precision livestock farming; however, a major bottleneck in their development remains the scarcity of high-quality, high-granularity physiological data. This study introduces the expert-informed conditional diffusion (EICD) framework, a novel approach to synthesizing high-fidelity metabolic time-series trajectories by embedding mechanistic biological principles directly into the generative process. While traditional generative models often prioritize statistical pattern-matching over biological reality, frequently resulting in physiological hallucinations, the EICD framework utilizes a physiology loss function (PhLF) to act as a form of mechanistic regularization. This guardrail penalizes samples that contradict expert-defined constraints, such as the laws of porcine bioenergetics, effectively steering the model toward a realistic physiological manifold. The framework was validated using an empirical dataset of growing pigs under varying thermal conditions. Quantitative results demonstrate near-perfect statistical distributional fidelity, with the model achieving an average Jensen-Shannon divergence (JSD) of 0.062 and a Kullback-Leibler divergence (KLD) of 0.19. The full EICD model produced a mean energy expenditure (EE) of 284.94 {+/-} 38.70 kJ/kg/day, mirroring the empirical average of 281.33 {+/-} 41.58 kJ/kg/day. In contrast, the standard generative diffusion model (i.e., with no physiology guardrail) exhibited significant distributional drift, yielding a mean EE of 334.41 kJ/kg/day. The biological integrity of the model was further assessed using the biological violation rate (BVR), a novel metric defined as the percentage of generated samples that fall outside the physically possible metabolic boundaries established by species-specific laws. While the standard diffusion model produced frequent biological artifacts, the EICD framework successfully suppressed these hallucinations, ensuring that synthetic trajectories remain strictly grounded in mechanistic laws. Despite these advancements, limitations remain at physiological extremes where individual stochasticity is high. By providing a reliable method for generating physiology-consistent synthetic data, this framework provides a robust foundation for the next generation of animal digital twins. HighlightsO_LIA novel expert-informed conditional diffusion (EICD) framework is proposed for physiology-consistent synthetic data generation in precision livestock farming. C_LIO_LIA physiology loss function (PhLF) embeds species-specific bioenergetic laws directly into the generative process as a mechanistic guardrail. C_LIO_LIThe framework achieves near-perfect distributional fidelity (JSD = 0.062) while suppressing physiological hallucinations (BVR = 0.93%). C_LIO_LIAn ablation study confirms that biological consistency is not an emergent property of standard diffusion models but requires explicit mechanistic constraints. C_LIO_LIThe framework provides a scalable solution for synthetic data augmentation in precision livestock farming, supporting the 3Rs and enabling high-throughput in silico experimentation. C_LI

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Youssef, A., Sun, C., Norton, T.. 2026-04-27. An Expert-Informed Synthetic Animal Data Generator: A Physiology-Consistent Generative Framework for High-Fidelity Animal Digital Twins. https://doi.org/10.64898/2026.04.23.720335

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Ferrybots: Programmable Hydrogel Microbots for Rapid Magnetic Navigation and Modular Function

Untethered microrobots could enable localized delivery, sensing, and intervention in confined biological and engineered environments. Magnetic actuation is especially attractive for such systems because it provides remote, fuel-free control, but practical magnetic microrobots remain difficult to manufacture and functionalize. High magnetic loading can interfere with polymerization and structural integrity, while integrating application-specific payloads directly into the robot body often requires the entire material formulation to be redesigned. Here, we introduce Ferrybots, programmable hydrogel microrobots that physically separate magnetic navigation from functional cargo. An automated droplet-on-demand microfluidic flow-lithography process confines high-concentration ferrofluid cores within photopolymerized poly (ethylene glycol) diacrylate (PEGDA) structures, enabling magnetic loading to be programmed through core number and spacing without uniformly dispersing magnetic particles throughout the hydrogel. The process achieved a minimum fabrication cycle time of 15 s. Ferrybots exhibited magnetic-dose-dependent translation and rotation, branched-channel steering, out-of-plane obstacle traversal, and rapid translation, with two-core robots following an external magnet at speeds up to the 9000 mm/min limit of the actuation system. Differences in magnetic loading also enabled sequential selective navigation of distinct Ferrybot populations. Using PEGDA 575 as a common interface material, independently formulated hydrogel cargo modules could subsequently be fused to preformed Ferrybots while preserving navigation. Separately, cargo modules enabled composition-dependent molecular release and oxygen-responsive sensing through 1-mm-thick skin-mimicking optical phantoms representing a broad range of skin types. By decoupling locomotion from function, Ferrybots provide a common magnetic vehicle that can be combined with interchangeable delivery, sensing, or responsive-material modules, offering a general strategy for rapidly adapting microrobots to different applications.

bioengineering↗

Circular-Arc Modal Migration for Ultrasound Imaging--Part I: Finite-Arc Spectral Theory and Stolt-Pullback Factorization

Circular-arc ultrasound imaging requires a spectral construction that accommodates radius-dependent propagation and the spatially varying phase of offset-source transmission. This first of two articles develops Circular-Arc Modal Migration (CAMM), a direct Stolt-type imaging framework in angular modal coordinates. Starting from a first-Born acoustic model, angular decomposition and local radial Stolt mappings convert channel spectra into fields for coherent image synthesis. The offset transmit phase is represented by a phase-screen factorization through reusable spectral factors and spatially weighted fields. A scalar-pullback approximation simplifies this correction to reading one reference image at a geometrically fitted radial coordinate. Both realizations share the same modal construction. Error controls address local radial synthesis, transmit-path expansion, scalar approximation, and phase-screen truncation, with direct integration verifying the separated numerical evaluation. Same-RF point-target comparisons show that scalar pullback closely preserves the principal peak positions and widths of phase-screen imaging in the compact semicircular configuration, while phase screens better control surrounding responses in the shallow convex examples. The retained modal spectrum, frequency band, image radius, and source displacement guide this accuracy--computation choice. CAMM thereby extends direct spectral image formation to circular arcs and supplies the theoretical and numerical basis for the image-quality and performance studies in Part~II.

bioengineering↗

Identification and isolation of migratory subpopulations of cancer cells using microfluidics with fluid walls

Microfluidic assays have great potential for investigating cancer cell migration, a key process underlying metastasis which remains a major clinical challenge. However, adoption by biologists is limited due to complex fabrication and operation methods combined with difficulty in retrieving cells of interest. We jet-print dumbbell-shaped microfluidic environments with fluid walls in standard Petri dishes in seconds using standard growth media and immiscible oil. Prostate cancer cells and chemoattractant (bovine serum) are introduced into each end using local transient differences in Laplace pressure to enable spatial confinement. Automated live-cell imaging monitors chemotaxis towards serum using standard microscopes, as the confining fluid walls are optically transparent. Distinct subpopulations of migratory cells exhibit different morphologies and motilities, assessed using a custom machine-learning segmentation model. Then, we leverage the reconfigurability of fluid walls to isolate and retrieve rapidly-migrating single cells. This demonstrates that fluid-walled microfluidics is a versatile and accessible approach for investigating cancer cell migration at single-cell resolution, offering new opportunities to examine cellular heterogeneity in metastasis.

bioengineering↗