Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.04.23.720095

In Vitro Fertilization using Magnetotactic Sperm Cells

Abstract

In vitro fertilization (IVF) is essential for many couples facing infertility, e.g. in cases of low sperm count (oligospermia), where natural fertilization is unlikely. Medical microrobotics, making use of microscopic devices designed to perform targeted tasks inside the body under imaging guidance and controlled actuation, represents a promising strategy to guide sperm cells toward the oocyte. This approach may significantly reduce the time, invasiveness, and patient burden of conventional IVF, with long-term potential for in vivo assisted reproduction. Here, we report the first successful in vitro fertilization (IVF) using magnetically functionalized spermatozoa, termed magnetotactic sperm cells (MSCs), as a step toward in vivo microrobotic guidance of sperm cells for targeted artificial insemination. We present a protocol for the preparation of MSCs for their use in IVF, resulting in samples largely free of non-functionalized sperm cells (99.69% purity). We systematically evaluate the effect of particle functionalization on sperm health, including acrosome integrity, DNA fragmentation, mitochondrial membrane potential, oxidative stress, and epithelial interactions, and observe no adverse effects. Notably, MSCs showed improved mitochondrial membrane integrity compared to the control samples after two hours of incubation. Using MSCs, we successfully performed complete IVF cycles that resulted in embryos developing to the blastocyst stage at a comparable rate as non-functionalized sperm cells of the same concentration. Lower concentrations of non-functionalized sperm cells (comparable to those remaining in the MSC sample after purification) did not result in any development of embryos to blastocysts. To facilitate manipulation and translation, we implemented automated image-based recognition, magnetic manipulation, and pre-clustering routines that increased guidance efficiency and are compatible with standard IVF workflows. Together, these results demonstrate that magnetic functionalization can be applied without compromising key sperm quality metrics and can enable directed sperm guidance for assisted oocyte fertilization. This work provides a practical framework for integrating microrobotic sperm manipulation into assisted-reproduction workflows and supports further development toward automated in vitro and eventual in vivo applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ribeiro, C., Striggow, F., Nauber, R., Hebenstreit, F., Schoen, J., Medina-Sanchez, M.. 2026-04-27. In Vitro Fertilization using Magnetotactic Sperm Cells. https://doi.org/10.64898/2026.04.23.720095

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗