Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.04.22.720171

Characterization and Validation of Compressed Sensing for Time-of-Flight MRI Angiography of the Human Brain at 3T and 7T

Abstract

BackgroundCerebral vasculature is a key biomarker of brain health, and time-of-flight (TOF) magnetic resonance angiography (MRA) provides noninvasive assessment of vascular anatomy. However, conventional TOF-MRA requires long scan times, increasing patient burden and susceptibility to motion artifacts. Compressed sensing (CS) offers a feasible acceleration strategy. PurposeTo quantitatively evaluate CS acceleration in TOF-MRA at 3T and 7T using automated whole-FOV vascular segmentation and semi-automatic segmentation of representative vessels. Study typeProspective Population23 healthy human participants (3T) and 8 healthy human participants (7T). Field Strength/SequenceCS TOF-MRA (CS factors 4 and 8 at 3T; 8 at 7T) was compared against non-accelerated (CS0) TOF-MRA. AssessmentVisual comparison and vascular segmentation were performed using automated whole-FOV methods and semi-automatic segmentation of the posterior cerebral artery and anterior choroidal artery. Statistical TestsContrast-to-noise ratio (CNR), voxel count, and vessel diameter were assessed using two-tailed paired t-tests. ResultsWhole-FOV CNR differed significantly across CS factors at 3T (CS0 > CS4: p < 0.001, d = 0.77; CS0 < CS8: p = 0.008, d = 0.36; CS4 < CS8: p < 0.001, d = 1.11) and 7T (CS0 < CS8: p = 0.002, d = 0.54), with semi-automatic segmentation yielding consistent findings (p < 0.01 for all comparisons). The diameter measurements for segmented vessels are also higher with high CS-factors (PCA 7T: left: p = 0.006, d = 0.93, right: p = 0.045, d = 0.43; AChA 7T: left: p < 0.001, d = 0.66, right: p = 0.009, d = 1.06; PCA 3T: p < 0.001 for all comparison dLeft = 0.52 (CS0 vs. CS4), 0.56 (CS4 vs. CS8), 1.11 (CS0 vs. CS8) and dRight = 0.78 (CS0 vs. CS4), 0.57 (CS4 vs. CS8), 1.17 (CS0 vs. CS8)). Data ConclusionCS shows promise for enhancing clinical applicability of TOF-MRA, with advantages most pronounced at 7T.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Radman, G., Zhong, X. Z., Kulkarni, M., Perosa, V., Matthews, J. J. L., Callaghan, M. F., Duzel, E., Hammerer, D., Femminella, G. D., Chen, J. J., Olsen, R.. 2026-04-24. Characterization and Validation of Compressed Sensing for Time-of-Flight MRI Angiography of the Human Brain at 3T and 7T. https://doi.org/10.64898/2026.04.22.720171

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Ferrybots: Programmable Hydrogel Microbots for Rapid Magnetic Navigation and Modular Function

Untethered microrobots could enable localized delivery, sensing, and intervention in confined biological and engineered environments. Magnetic actuation is especially attractive for such systems because it provides remote, fuel-free control, but practical magnetic microrobots remain difficult to manufacture and functionalize. High magnetic loading can interfere with polymerization and structural integrity, while integrating application-specific payloads directly into the robot body often requires the entire material formulation to be redesigned. Here, we introduce Ferrybots, programmable hydrogel microrobots that physically separate magnetic navigation from functional cargo. An automated droplet-on-demand microfluidic flow-lithography process confines high-concentration ferrofluid cores within photopolymerized poly (ethylene glycol) diacrylate (PEGDA) structures, enabling magnetic loading to be programmed through core number and spacing without uniformly dispersing magnetic particles throughout the hydrogel. The process achieved a minimum fabrication cycle time of 15 s. Ferrybots exhibited magnetic-dose-dependent translation and rotation, branched-channel steering, out-of-plane obstacle traversal, and rapid translation, with two-core robots following an external magnet at speeds up to the 9000 mm/min limit of the actuation system. Differences in magnetic loading also enabled sequential selective navigation of distinct Ferrybot populations. Using PEGDA 575 as a common interface material, independently formulated hydrogel cargo modules could subsequently be fused to preformed Ferrybots while preserving navigation. Separately, cargo modules enabled composition-dependent molecular release and oxygen-responsive sensing through 1-mm-thick skin-mimicking optical phantoms representing a broad range of skin types. By decoupling locomotion from function, Ferrybots provide a common magnetic vehicle that can be combined with interchangeable delivery, sensing, or responsive-material modules, offering a general strategy for rapidly adapting microrobots to different applications.

bioengineering↗

Circular-Arc Modal Migration for Ultrasound Imaging--Part I: Finite-Arc Spectral Theory and Stolt-Pullback Factorization

Circular-arc ultrasound imaging requires a spectral construction that accommodates radius-dependent propagation and the spatially varying phase of offset-source transmission. This first of two articles develops Circular-Arc Modal Migration (CAMM), a direct Stolt-type imaging framework in angular modal coordinates. Starting from a first-Born acoustic model, angular decomposition and local radial Stolt mappings convert channel spectra into fields for coherent image synthesis. The offset transmit phase is represented by a phase-screen factorization through reusable spectral factors and spatially weighted fields. A scalar-pullback approximation simplifies this correction to reading one reference image at a geometrically fitted radial coordinate. Both realizations share the same modal construction. Error controls address local radial synthesis, transmit-path expansion, scalar approximation, and phase-screen truncation, with direct integration verifying the separated numerical evaluation. Same-RF point-target comparisons show that scalar pullback closely preserves the principal peak positions and widths of phase-screen imaging in the compact semicircular configuration, while phase screens better control surrounding responses in the shallow convex examples. The retained modal spectrum, frequency band, image radius, and source displacement guide this accuracy--computation choice. CAMM thereby extends direct spectral image formation to circular arcs and supplies the theoretical and numerical basis for the image-quality and performance studies in Part~II.

bioengineering↗

Identification and isolation of migratory subpopulations of cancer cells using microfluidics with fluid walls

Microfluidic assays have great potential for investigating cancer cell migration, a key process underlying metastasis which remains a major clinical challenge. However, adoption by biologists is limited due to complex fabrication and operation methods combined with difficulty in retrieving cells of interest. We jet-print dumbbell-shaped microfluidic environments with fluid walls in standard Petri dishes in seconds using standard growth media and immiscible oil. Prostate cancer cells and chemoattractant (bovine serum) are introduced into each end using local transient differences in Laplace pressure to enable spatial confinement. Automated live-cell imaging monitors chemotaxis towards serum using standard microscopes, as the confining fluid walls are optically transparent. Distinct subpopulations of migratory cells exhibit different morphologies and motilities, assessed using a custom machine-learning segmentation model. Then, we leverage the reconfigurability of fluid walls to isolate and retrieve rapidly-migrating single cells. This demonstrates that fluid-walled microfluidics is a versatile and accessible approach for investigating cancer cell migration at single-cell resolution, offering new opportunities to examine cellular heterogeneity in metastasis.

bioengineering↗