Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.04.14.718500

MRI-Based Blood Clot Phenotyping: An In Vitro Study

Abstract

Background and PurposeNeurointerventional outcomes depend on clot composition and may be influenced by clot contraction. Thus, a priori identification of clot composition and contraction could inform procedural strategies and improve outcomes. The goal of our work is to conduct an in vitro test to determine whether MRI can reliably predict both clot composition and contractile state. Materials and MethodsTo this end, we prepared blood clots spanning clinically observed compositions (0-80% red blood cells (RBCs)) in both contracted and uncontracted states. Contraction was controlled by coagulating blood with or without thrombin. We imaged these clots using quantitative, clinical, and investigational MRI sequences. Using these data, we then determined whether MRI signal intensities, quantitative parameters, and radiomic features capturing intensity and texture patterns can (i) predict clot hematocrit and (ii) classify clots by composition (RBC-rich vs. fibrin-rich) and contraction state. ResultsQuantitative MRI parameters (T1, T2, ADC) decreased with increasing hematocrit (R2 = 0.56-0.85, p < 0.001), while signal intensities from clinical sequences showed weaker correlations (R2 = 0.46-0.62, p < 0.001). Radiomic models predicted hematocrit with performance comparable to MRI parameters. When applied to classification, radiomic features accurately discriminated RBC-versus fibrin-rich clots, with AUCs exceeding 0.90 across nearly all sequences. In contrast, classification of contraction state showed greater variability in AUCs across sequences but remained high for quantitative T1 and T2 values (AUCs up to 0.88). Trends were consistent across clots coagulated with and without thrombin. Pooling features across sequences did not outperform the best individual sequence for either regression or classification. ConclusionsWe demonstrate that MRI-based radiomic analysis quantitatively characterizes clot composition and contraction in vitro. These findings support the feasibility of using MRI for pre-interventional clot phenotyping, with potential to inform thrombolytic and mechanical thrombectomy strategies. Thus, in vivo studies validating these results are warranted.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bechtel, G. N., Das, A., Noyer, J., Bush, A. M., Hormuth, D., Yankeelov, T. E., Castillo, E., Warach, S., Fuhg, J., Tamir, J. I., Saber, H., Rausch, M. K.. 2026-04-16. MRI-Based Blood Clot Phenotyping: An In Vitro Study. https://doi.org/10.64898/2026.04.14.718500

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗