Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.04.01.715903

miRNova: A Next-Generation Platform for Ultra-Precise and Highly Specific MicroRNA Quantification Integrating a Tailored Stem Loop RT-qPCR and a Robust Analytical Framework

Abstract

MicroRNAs (miRNAs) are ultra-short RNA molecules characterized by high sequence homology, frequent post-transcriptional modifications, and typically low abundance, particularly in circulating biofluids. These inherent biological features present substantial technical challenges for RT-qPCR- based quantification. Consequently, the development of miRNA RT-qPCR assays has required architectural adaptations at the reverse transcription (RT) stage to generate extended cDNA templates, thereby enabling effective downstream quantitative PCR amplification. One widely adopted approach involves the enzymatic addition of a poly(A) tail to the 3' end of miRNAs, followed by poly(T)-primed universal reverse transcription, which has gained broad acceptance due to its perceived sensitivity and simplified workflow. However, independent experimental evidence indicates that this architecture does not consistently provide the level of specificity required for reliable single-nucleotide (SN) discrimination, particularly when quantifying low-abundance circulating miRNA targets, as demonstrated in our previous study. An alternative strategy relies on miRNA-specific reverse transcription using stem-loop priming has been equally well accepted. When generically generated, this approach offers certain improved specificity, but its performance in resolving single-nucleotide differences remains limited. In this article, we employed precision engineering to maximize specificity for both reverse transcription and qPCR steps. By tailoring both primer design and reaction architecture to the specific sequence features of each miRNA, we enable robust single nucleotide discrimination among these ultra-short targets. Prototype of ten different miRNova assays quantifying miRNAs whose sequences are differed in various configurations were tested on synthetic miRNA targets. For miRNova assay validation, saliva samples were elite rugby players submitted to small RNA extraction, then RT-qPCR. Spike-in of synthetic targets was applied for each quantification point to characterized the sensitivity, specificity and accuracy of the assays. Comparative analysis was performed between miRNova and two commercially available kits on the same sample set. The obtained results show a superior performance of miRNova assays allowing for sensitive and accurate quantification of miRNAs in saliva samples. Altogether, this results in modular, reproducible assays optimized for low-abundance miRNA detection in challenging biofluids, including saliva, positioning the platform beyond existing sensitivity-focused solutions toward true diagnostic-grade specificity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

VAN, T. N. N., Van Der Hofstadt, M., Houot-Cernettig, J., Thibal, C., Nguyen, H. S., Marcelin, C., Ouedraogo, A., Champigneux, P., Molina, L., Kahli, M., Molina, F.. 2026-04-04. miRNova: A Next-Generation Platform for Ultra-Precise and Highly Specific MicroRNA Quantification Integrating a Tailored Stem Loop RT-qPCR and a Robust Analytical Framework. https://doi.org/10.64898/2026.04.01.715903

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗