Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.03.20.712251

A New Mathematical Model for LVAD-Supported Ventricles: Direct Parameterization from Ramp-Test Clinical Data and Verification via Hybrid Modeling

Abstract

BackgroundConventional left ventricular assist device ramp metrics are load dependent, obscuring intrinsic myocardial recovery. A mechanistic, patient-specific representation of ventricular mechanics, identifiable from routine clinical data, could provide quantitative indices of intrinsic left ventricular (LV) function for longitudinal recovery surveillance. ObjectiveTo develop and verify a ramp-integrated, patient-specific model of HeartMate 3-assisted LV function that can yield indices of intrinsic myocardial contractility and remodeling. MethodsWe represented LV pressure-volume (PV) behavior with a PV envelope composed of a monotonic passive PV relation (pPVR) and a unimodal active PV relation (aPVR). We developed a parameterization procedure to infer the patient-specific shape of this envelope directly from routine ramp-test data. We then embedded the parameterized envelope within the PSCOPE framework, a hybrid platform that couples a lumped-parameter network to a physical HeartMate 3 flow loop, to reproduce clinical ramp hemodynamics. Percent residuals between simulated outputs and the corresponding clinical measurements verified the implementation of the PV envelope within PSCOPE. ResultsIn three HeartMate 3 recipients, the PSCOPE models reproduced ramp hemodynamics with residuals generally [≤] 20% across pump speeds and measured variables. Cardiac index residuals ranged from 0-18.5%, systemic and pulmonary arterial pressure residuals remained [≤] 18.4%, and pulmonary arterial wedge pressure residuals remained [≤] 20%. The PSCOPE models matched central venous pressure within [≤] 3 mmHg in all cases, although one setting yielded a 33.3% residual due to a low reference pressure. For one patient, the model reproduced ramp hemodynamics at a speed deliberately withheld from PV-envelope parameterization with residuals [≤] 10%, supporting cross-speed generalizability. Patient-specific PV envelopes also revealed clinically meaningful heterogeneity in LV diastolic stiffness, volume threshold for declining systolic function, operating PV points for peak systolic function, and contractile reserve. ConclusionsRamp-integrated parameterization of the monotonic pPVR and unimodal aPVR yields a compact, mechanistic PV envelope that is identifiable from routine clinical data and verifiable within PSCOPE. The resulting indices characterize intrinsic LV function and may enhance longitudinal recovery surveillance and inform LVAD management. Prospective multicenter validation is warranted to confirm the generalizability and clinical utility of this approach.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Umo, A., Welch, B., Kilic, A., Kung, E.. 2026-03-23. A New Mathematical Model for LVAD-Supported Ventricles: Direct Parameterization from Ramp-Test Clinical Data and Verification via Hybrid Modeling. https://doi.org/10.64898/2026.03.20.712251

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗