Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.03.09.710404

Ion Channel Nano-Diagnostics for ER+ Breast Cancer

Abstract

Ion channels are pore-forming transmembrane proteins that allow ions to move down an electrochemical gradient and across the channel pore and regulate many cell functions. Among them, are the G-protein-gated inwardly-rectifying K+ channels 1 (GIRK1) that are ubiquitously expressed with major functions in the brain and heart. Interestingly, significantly higher GIRK1 expression has been found in estrogen receptor positive (ER+) breast cancer patients compared to patients with HER2+ tumors or normal patients, and that was statistically correlated with shorter survival times and metastatic potential. Herein, we report the preparation of [~]4 nm GAT1508-coated poly(ethylene glycol) gold nanoparticle (PEGylated AuNP) biomarker for ER+ breast cancer cell screening through an optical microscope. A urea-based small molecule, GAT1508, with an N-methylpyrazole benzyl group on one side and a bromo-thiophene tail on the other side, has been shown to predominantly bind GIRK1 subunits and specifically activate GIRK1/2 channels. Two derivatives of GAT1508were synthesized and characterized: an ethylamine derivative (GAT1508-EA) with a chain extension from the benzyl ring, and a propylamine derivative (GAT1508-PA) with a chain extension from the pyrazole ring. Electrophysiology (TEVC and whole-cell patch-clump) experiments as well as fluorescence studies (Thallium assay) showed that only GAT1508-PA inhibited GIRK1/2-mediated K+ currents in transfected HEK293GIRK1 cells. Docking studies showed strong binding for the propylamine GAT1508 derivative, both in the amine form (GAT1508-PA) as well as in the amide form (GAT1508-PA-EG2; coupled with PEG as in the AuNPs). GAT1508-PEG-AuNPs (GAT1508-NPs) were synthesized subsequently with [~]65 wt% metal loading. UV-Vis studies revealed the presence of the conjugated ligand at 260 nm. Flow cytometry studies showed binding of Alexa 594-labeled GAT1508-NPs in ER+ MCF-7 breast cancer cells with a strong interaction, while incubation of fixed MCF-7 cells with a GAT1508-NP solution led to optical detection of ER+ breast cancer cells, without the need of fluorescent dyes and additional amplification steps. Detection was not feasible in MDA-MB-231 cells, a triple (-) breast cell line that does not express GIRK1. This is the first study, to our knowledge, that couples nanotechnology with small molecule drug design and electrophysiology to develop ion channel-tracing molecular probes for the detection/screening of ER+ breast cancer.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gkikas, M., Dadiotis, E., Zaka, M., Aly, N., Chan, K., Logothetis, D. E.. 2026-03-11. Ion Channel Nano-Diagnostics for ER+ Breast Cancer. https://doi.org/10.64898/2026.03.09.710404

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Single-Component Photo-Crosslinked Lipoic Acid Functionalized Mucin Hydrogels: Dynamic Mucus Mimetics for Antiviral Protection

Native mucus protects epithelial surfaces through viscoelastic networks of disulfide-linked mucins. However, commercially available mucins often fail to reconstitute comparable mechanical and barrier properties, while synthetic and hybrid mucus mimetics require polymeric crosslinkers that may alter mucus-like composition. Inspired by the native architecture, we directly functionalized porcine gastric and bovine submaxillary mucins with -lipoic acid to develop a single-component, photo-crosslinkable hydrogels. Upon UV irradiation (365 nm), the modified mucins rapidly form disulfide-crosslinked networks without added photo-initiator/ polymeric crosslinkers, two orders of magnitude faster as compared with PEG-SH approaches. The resulting mucin-lipoic acid (MUC-LA) hydrogels exhibit mucus-relevant properties, including tunable viscoelasticity, redox responsiveness, self-healing, and size-dependent restrictions on nanoparticle transport. In transwell-based infection models, MUC-LA hydrogels (2-3%) mimicking the healthy airway mucus (G' {approx} 10-20 Pa) suppress epithelial infection by SARS-CoV-2 and influenza A virus. Crosslinked MUC-LA provides greater protection against SARS-CoV-2 than the non-crosslinked, whereas both formulations suppress influenza A infection, suggesting distinct contributions from network formation and mucin-associated interactions. These findings establish a dynamic, mucus-mimetic platform integrating rapid photo-gelation, controllable mechanics, selective transport, and antiviral barrier functionality. MUC-LA hydrogels offer opportunities to investigate mucosal transport and host-pathogen interactions, with potential applications in drug delivery, and as biomaterials.

bioengineering↗

Population-level emulation enables fast Bayesian calibration of cardiac digital twins

Purpose: Patient-specific cardiac digital twins have the potential to guide individualized therapy, but generating these in a routine clinical workflow remains challenging. This is especially true when the twins must carry quantified uncertainty: Bayesian calibration requires thousands of simulations per patient, and the emulators that reduce this cost are typically trained one patient at a time. We aimed to train a single emulator across a patient cohort, so that a new patient can be calibrated in minutes without new simulations. Methods: We trained a population-level Gaussian process emulator whose inputs included a 12-dimensional latent encoding of the clinical features of each patient, so that a single emulator represents the whole cohort. We compared spending simulation budgets on resampling the real cohort with augmenting the cohort with digital chimeras, synthetic patients interpolated between real patients. Seven parameters of a closed-loop heart and circulation model were calibrated by Markov chain Monte Carlo to ten clinical biomarkers in 26 patients with left bundle branch block, each using an emulator trained without that patient, and the calibrated posteriors were compared against the full simulator. Results: A single emulator, trained without the held-out patient, calibrated the digital twin of each patient in 59.7-63.0 s per patient, versus 15 h with the simulator. Resampling the real cohort was the more efficient training strategy, bringing every output to R2 greater than or equal to 0.9, which augmentation did not achieve for the same simulation budget. For held-out patients, both strategies performed comparably (median leave-one-out normalized root-mean-square error 11.0% vs. 10.7%; p = 0.745), and error rose with distance from the cohort centroid (Spearman rho = +0.406). The calibrated models showed no cohort-wide bias (median standardized residual -0.12 against the clinical targets), and 95% predictive intervals contained 78.5% of targets, with the largest misfit in systolic blood pressure. Conclusion: Removing the need for new simulations for every new patient is a meaningful step toward uncertainty-aware cardiac digital twins that fit within a routine clinical workflow. Because the simulator, surrogate and sampler are interchangeable, the approach used here can be applied to other (cardiac) models and cohorts.

bioengineering↗

Multi-Structure Segmentation of Type B Aortic Dissection from CT Images with U-Net

Type B aortic dissection (TBAD) is a life-threatening condition in which a tear in the intimal layer separates the aortic wall into a true and a false lumen. Assessment of the lumen, the intimal flap, and false-lumen thrombosis from CT images is important for risk analysis and treatment planning. This work applied U-Net-based deep neural networks to the automatic segmentation of these structures in TBAD. We collected 46 CT scans from 20 patients, with voxel-wise annotations of three structures: the aortic lumen, the intimal flap, and the thrombus. We explored four models: two convolutional networks, nnU-Net 2D and 3D, and two transformer-based architectures, TransUNet 2D and 3D. We observed that (1) for both nnU-Net and TransUNet, the 3D models outperformed their 2D counterparts on all three structures. The difference was small for the aortic lumen but large for the thin flap and the thrombus. The best model, nnU-Net 3D, reached a DSC of 93.05% for the lumen, 50.22% for the flap, and 69.94% for the thrombus. (2) The intimal flap was the most difficult structure for all models. Even the best 3D models showed large thrombus boundary errors in a few scans. These results provide a baseline for developing more advanced models for accurate segmentation of these structures in TBAD.

bioengineering↗