Search bioRxiv⌕ Search

bioRxiv · 10.64898/2026.02.19.706828

Recalibrating Nanoparticle Protein Corona Analysis for Accurate Biological Identity and Soluble Plasma Proteome Profiling

Abstract

The nanoparticle (NP) protein corona is considered the biological identity that determines NP fate, safety, targeting, and therapeutic effectiveness in biofluids. Nonetheless, standard corona isolation workflows assume the recovered protein signature originates primarily from plasma proteins adsorbed directly onto the NP surface, while largely overlooking co-isolation of endogenous nanoscale biological structures such as extracellular vesicles (EVs). This oversight can distort the apparent "biological identity" of the NP. Here, we show that EVs are a major hidden contributor to the perceived protein corona composition in human plasma. Using highly monodispersed polystyrene NPs (50-1000 nm) and superparamagnetic beads, we compared corona formation in standard human plasma and plasma depleted of an EV- enriched sedimentable fraction by ultracentrifugation at 100,000 x g for 2 h, with the recovered vesicles subsequently characterized by MACSPlex immunoaffinity analysis. Mass spectrometry revealed that EV depletion reduced the number of proteins identified on polystyrene NPs by 60-75% and on magnetic beads by 45-50%, demonstrating a substantial fraction of the conventionally assigned corona proteome arises from EV- associated carryover. EV depletion also restructured the apparent abundance hierarchy, increasing the relative prominence of soluble plasma proteins such as albumin and shifting dominant signals away from intracellular cytoskeletal component proteins that are characteristic of EV carryover towards genuine soluble plasma proteins and complement factors. These results highlight that standard corona workflows can inadvertently co-isolate a vast array of EV-associated material and thereby yield inaccurate assignments of protein origin. Distinguishing proteins adsorbed from the soluble phase from EV-surface and intravesicular material is essential for accurate interpretation of NP-biofluid interactions, biomarker discovery, and therapeutic targeting because molecular compartment determines both analytical meaning and drug accessibility. Significance StatementThe nanoparticle (NP) "protein corona" defines how engineered nanomaterials interact with living systems, influencing therapeutic safety, efficacy, and diagnostic utility. Conventionally, corona isolation workflows assume that recovered proteins were adsorbed directly from the fluid phase. This study reveals a major, previously overlooked source of analytical distortion: standard separation techniques routinely co-isolate endogenous extracellular vesicles (EVs), drastically distorting the perceived biological identity of NPs. Depletion of an EV-enriched sedimentable fraction by ultracentrifugation reduced identified corona proteins by up to 75% and restructures the apparent proteomic hierarchy. Distinguishing true soluble adsorbates from vesicular carryover is essential for accurately predicting NP behavior in vivo and prevents false positives in nano- diagnostics, establishing a critical new standard for high-fidelity biomarker discovery and nanomedicine.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ghaffari, B., Grumelot, S., Sadeghi, S. A., Alpaydin, A., Hilsen, K., Shango, B., Ritz, D., Schmidt, A., Vali, H., Sun, L., Saei, A. A., Borhan, B., Mahmoudi, M.. 2026-02-20. Recalibrating Nanoparticle Protein Corona Analysis for Accurate Biological Identity and Soluble Plasma Proteome Profiling. https://doi.org/10.64898/2026.02.19.706828

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Wall stiffening is a primary contributor to motility loss in Crohn's disease: an electromechanical modeling study

Fibrotic strictures are among the most disabling complications of Crohn's disease, permanently narrowing the bowel and impairing motility, yet no approved therapy reverses them. Chronic inflammation alters pacemaker-network coupling, smooth-muscle excitability, and calcium-dependent contractility, while fibrosis thickens the bowel wall, narrows the lumen, and changes tissue mechanics. The relative contributions of these coupled electrical, contractile, and structural alterations to motility loss remain unclear. To address this gap, we develop an integrated electromechanical finite-element framework for fibrostenosing Crohn's disease that couples a fibrosis-driven growth model with a FitzHugh-Nagumo electromechanical model. A full-factorial 25 design of experiments is used to quantify the relative effects of electrical diffusivity, excitation threshold, peak active stress, wall stiffness, and hypertrophic remodeling on cyclic lumen-volume deformation. Motility is quantified by the standard deviation of lumen volume over one contraction cycle. Within the parameter ranges examined, increased wall stiffness emerged as the dominant contributor to motility loss, followed by impaired smooth-muscle contractility. Changes in excitation threshold, hypertrophic remodeling, and electrical diffusivity produced substantially smaller effects. Pairwise interactions were small relative to the dominant main effects, indicating that the mechanisms contributed largely through their individual effects. Our findings suggest that limiting wall stiffening while preserving smooth-muscle contractile function may provide a therapeutic strategy for maintaining intestinal motility in fibrostenosing Crohn's disease.

bioengineering↗

Lactate Receptor Activation Alleviates Senescence and Preserves Homeostasis of Aged Arteries

Arteries are among the first tissues to exhibit age-related dysfunction, yet the metabolic mechanisms driving vascular senescence remain poorly understood. Here, analysis of human aortic transcriptomic data identified HCAR1, encoding the lactate receptor GPR81, as one of the genes most significantly downregulated with age. We therefore investigated whether age-associated loss of GPR81 contributes to cellular senescence within the vessel wall. Senescent human endothelial cells and vascular smooth muscle cells accumulated neutral and oxidized lipids and exhibited increased labile iron and ferroptosis. Silencing GPR81 in early-passage cells recapitulated this metabolic phenotype together with multiple hallmarks of cellular senescence. Moreover, endothelial-specific deletion of GPR81 in young mice was sufficient to induce senescent cell accumulation, impaired lipid homeostasis, endothelial dysfunction, and elastin disorganization. Conversely, pharmacological activation of GPR81 with the agonist CHBA restored fatty acid metabolism, promoted glycolytic reprogramming, and attenuated ferroptotic stress and senescence-associated phenotypes. In lamin A knock-in (LAKI) progeroid mice, CHBA reduced arterial lipid accumulation and cellular senescence, shifted vascular cell composition toward a youthful state, improved endothelial integrity, and restored extracellular matrix homeostasis. Together, these findings identify age-associated loss of GPR81 as a driver of vascular metabolic dysfunction and cellular senescence and establish pharmacological GPR81 activation as a promising therapeutic strategy for preserving vascular homeostasis and mitigating age-associated cardiovascular disease.

bioengineering↗

Targeted and bilateral blood flow monitoring in middle cerebral artery using diffuse correlation spectroscopy

Objective: To develop and validate a dual-probe Diffuse Correlation Spectroscopy (DCS) system for non-invasive and simultaneous, monitoring of cerebral blood flow (CBF) in the bilateral Middle Cerebral Artery (MCA) territories, and expanding the utility of conventional DCS limited to cortical-volume-based CBF measurements to vessel-specific cerebral perfusion monitoring. Methods: A dual-probe DCS system was designed for non-invasive monitoring of MCA-specific perfusion. Probe placement and protocol optimization study has been performed using anatomical landmarks, motor and speech activation tasks in healthy volunteers. System stability and repeatability were further evaluated in a pilot cohort of 30 healthy (age, 25{+/-}7 years) participants using optimized probe position and protocol. A bilateral MCA ischemic Lacunar Infract stroke case report also validated the feasibility of the system in clinical settings. Results: Measurements demonstrated superior sensitivity towards MCA-territory perfusion at targeted probe locations compared to off-MCA positions. In pilot cohort, significant increase of 30.34 {+/-} 21.56% and 36.48 {+/-} 21.22% in rCBF corresponding to hand squeeze and speech task respectively showed reproducible physiological responsiveness of the system (p<0.001). Measurement done on a patient with bilateral MCA ischemic Lacunar Infract stroke showed a significant change of 30% during speech for both the MCAs but no significant change is observed for hand squeeze tasks. Conclusion: The custom built dual-probe DCS system enables non-invasive, operator-independent, targeted and continuous monitoring of rCBF within bilateral MCA territories. Significance: This approach enables the potential use of DCS system for bilateral and vessel-specific monitoring of cerebral perfusion in the MCA territories.

bioengineering↗