Feasibility of Automated Deep Learning Design for Medical Image Classification by Healthcare Professionals with Limited Coding Experience

Abstract

Deep learning has huge potential to transform healthcare. However, significant expertise is required to train such models and this is a significant blocker for their translation into clinical practice. In this study, we therefore sought to evaluate the use of automated deep learning software to develop medical image diagnostic classifiers by healthcare professionals with limited coding - and no deep learning - expertise.\n\nWe used five publicly available open-source datasets: (i) retinal fundus images (MESSIDOR); (ii) optical coherence tomography (OCT) images (Guangzhou Medical University/Shiley Eye Institute, Version 3); (iii) images of skin lesions (Human against Machine (HAM)10000) and (iv) both paediatric and adult chest X-ray (CXR) images (Guangzhou Medical University/Shiley Eye Institute, Version 3 and the National Institute of Health (NIH)14 dataset respectively) to separately feed into a neural architecture search framework that automatically developed a deep learning architecture to classify common diseases. Sensitivity (recall), specificity and positive predictive value (precision) were used to evaluate the diagnostic properties of the models. The discriminative performance was assessed using the area under the precision recall curve (AUPRC). In the case of the deep learning model developed on a subset of the HAM10000 dataset, we performed external validation using the Edinburgh Dermofit Library dataset.\n\nDiagnostic properties and discriminative performance from internal validations were high in the binary classification tasks (range: sensitivity of 73.3-97.0%, specificity of 67-100% and AUPRC of 0.87-1). In the multiple classification tasks, the diagnostic properties ranged from 38-100% for sensitivity and 67-100% for specificity. The discriminative performance in terms of AUPRC ranged from 0.57 to 1 in the five automated deep learning models. In an external validation using the Edinburgh Dermofit Library dataset, the automated deep learning model showed an AUPRC of 0.47, with a sensitivity of 49% and a positive predictive value of 52%. The quality of the open-access datasets used in this study (including the lack of information about patient flow and demographics) and the absence of measurement for precision, such as confidence intervals, constituted the major limitation of this study.\n\nAll models, except for the automated deep learning model trained on the multi-label classification task of the NIH CXR14 dataset, showed comparable discriminative performance and diagnostic properties to state-of-the-art performing deep learning algorithms. The performance in the external validation study was low. The availability of automated deep learning may become a cornerstone for the democratization of sophisticated algorithmic modelling in healthcare as it allows the derivation of classification models without requiring a deep understanding of the mathematical, statistical and programming principles. Future studies should compare several application programming interfaces on thoroughly curated datasets.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Faes, L., Wagner, S. K., Fu, D. J., Liu, X., Korot, E., Ledsam, J. R., Back, T., Chopra, R., Pontikos, N., Kern, C., Moraes, G., Schmid, M., Sim, D., Balaskas, K., Bachmann, L., Denniston, A., Keane, P. A.. 2019-05-27. Feasibility of Automated Deep Learning Design for Medical Image Classification by Healthcare Professionals with Limited Coding Experience. https://doi.org/10.1101/650366

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Contrastive Learning Improves Generalization on M2OR Olfactory Binding Dataset

Olfaction-based biosensors stand to have profound impacts in fields such as medical diagnostics, national security, and drug discovery. A promising mode of vapor phase biodetection mimics volatile organic compound-olfactory receptor (VOC-OR) interactions with target-specific protein or peptide probes; however, lack of experimental coverage remains a core bottleneck. Current computational approaches aim to improve prediction of VOC-OR binding to reduce experimental burden, and current machine learning approaches fail to demonstrate a level of generalization that addresses current engineering challenges. Here, using the Molecular to Olfactory Dataset (M2OR) and Insect Olfactory Binding Protein Database (iOBPdb) datasets, data partitioning methods and their performance are evaluated on a neural network and contrastive learning framework on such VOC-OR binding datasets, varying: model training, architecture, and structure of the input data distribution. It was found that holding out certain chemical or proteomic motifs from the training data diminished model performance with a two layer neural network model. The model was able to generalize to state of the art performance (0.88 AUCROC) on every data split by applying a contrastive learning objective defined by shared molecular constituents and a stochastic sampler. This suggests the contrastive objective provides a strong inductive bias for neural networks to predict novel VOC-OR pairs. These findings highlight that model performance on pairwise biological interaction datasets can be inflated through identity leakage from constituent overlap, and emphasize the need for more robust evaluation protocols. Furthermore, we show contrastive regularization mitigates dataset degeneracy through enforcement of compatibility in the models latent geometry that may extend to other binder target-datasets where identity leakage confounds evaluation.

bioinformatics↗

Plate design confounds donor variation and model evaluation in single-cell perturbation screens

Single-cell screens of immune cells from many donors are used to study why individuals respond differently and to benchmark response models. Each donor-perturbation combination typically occupies one well, controls are grouped, and donors share one layout, so technical effects can look biological. Using a 90-cytokine screen, two compound screens, four cohorts and simulations, we show that well effects explain most replicate-control variation in abundant cell types, controls carry a shared offset, and identical control wells differ by hundreds of differentially expressed genes at a standard threshold, about as many as two receptor-negative proteins do. Negative controls, design-aware estimators and perturbation-specific evaluation change the interpretation of four recent analyses. A deep-learning model that scores below a perturbation-agnostic predictor under standard evaluation outperforms a simple baseline on perturbation-specific differences in two of three cell types (significantly in one with stricter controls), but predicts less well the component shared with inert wells.

bioinformatics↗

LinearRaccess: linear-time approximation of RNA accessibility without base-pair span limits

Motivation: RNA accessibility is the probability that every nucleotide in a contiguous interval is simultaneously unpaired; it is widely used to predict binding sites for RNA-binding proteins and other RNA-RNA interactions, often in the form of the opening energy, an equivalent measure on a logarithmic scale. Existing tools restrict the maximum base-pair span, discarding long-range base pairs that matter biologically. Others sample structures, introducing statistical variance, or compute accessibility exactly without a span limit, at cubic time cost. No existing method computes the accessibility of windows longer than one nucleotide deterministically in linear time while preserving long-range base pairs. We present LinearRaccess, which computes accessibility directly in linear time via beam-pruned inside-outside dynamic programming with a difference-array aggregation step, without restricting base-pair span. Results: For a sequence of length N and a fixed beam width b, LinearRaccess runs in O(N) time and O(Nb) memory. Against exact accessibility on 12,872 bpRNA-1m(90) sequences of 100-1,000 nt, its median opening-energy error is below 0.001 kcal/mol (0.14 kcal/mol for 700-1,000 nt), and it distinguishes windows of very small accessibility, including 35-nt windows, below the resolution of sampling-based estimates. LinearRaccess analyzes the full 29,903-nt SARS-CoV-2 genome in 419 seconds. Conclusion: LinearRaccess is the first method to compute the accessibility of windows longer than one nucleotide deterministically (without sampling) in linear time without restricting base-pair span. Availability: https://github.com/TakumiOtagaki/LinearRaccess, archived at Zenodo (https://doi.org/10.5281/zenodo.23598502).

bioinformatics↗