Search bioRxiv⌕ Search

bioRxiv · 10.1101/392969

AnatomyNet: Deep 3D Squeeze-and-excitation U-Nets for fast and fully automated whole-volume anatomical segmentation

Abstract

PurposeRadiation therapy (RT) is a common treatment for head and neck (HaN) cancer where therapists are often required to manually delineate boundaries of the organs-at-risks (OARs). The radiation therapy planning is time-consuming as each computed tomography (CT) volumetric data set typically consists of hundreds to thousands of slices and needs to be individually inspected. Automated head and neck anatomical segmentation provides a way to speed up and improve the reproducibility of radiation therapy planning. Previous work on anatomical segmentation is primarily based on atlas registrations, which takes up to hours for one patient and requires sophisticated atlas creation. In this work, we propose the AnatomyNet, an end-to-end and atlas-free three dimensional squeeze-and-excitation U-Net (3D SE U-Net), for fast and fully automated whole-volume HaN anatomical segmentation.\n\nMethodsThere are two main challenges for fully automated HaN OARs segmentation: 1) challenge in segmenting small anatomies (i.e., optic chiasm and optic nerves) occupying only a few slices, and 2) training model with inconsistent data annotations with missing ground truth for some anatomical structures because of different RT planning. We propose the AnatomyNet that has one down-sampling layer with the trade-off between GPU memory and feature representation capacity, and 3D SE residual blocks for effective feature learning to alleviate these challenges. Moreover, we design a hybrid loss function with the Dice loss and the focal loss. The Dice loss is a class level distribution loss that depends less on the number of voxels in the anatomy, and the focal loss is designed to deal with highly unbalanced segmentation. For missing annotations, we propose masked loss and weighted loss for accurate and balanced weights updating in the learning of the AnatomyNet.\n\nResultsWe collect 261 HaN CT images to train the AnatomyNet, and use MICCAI Head and Neck Auto Segmentation Challenge 2015 as the benchmark dataset to evaluate the performance of the AnatomyNet. The objective is to segment nine anatomies: brain stem, chiasm, mandible, optic nerve left, optic nerve right, parotid gland left, parotid gland right, submandibular gland left, and submandibular gland right. Compared to previous state-of-the-art methods for each anatomy from the MICCAI 2015 competition, the AnatomyNet increases Dice similarity coefficient (DSC) by 3.3% on average. The proposed AnatomyNet takes only 0.12 seconds on average to segment a whole-volume HaN CT image of an average dimension of 178 x 302 x 225. All the data and code will be availablea.\n\nConclusion1We propose an end-to-end, fast and fully automated deep convolutional network, AnatomyNet, for accurate and whole-volume HaN anatomical segmentation. The proposed Anato-myNet outperforms previous state-of-the-art methods on the benchmark dataset. Extensive experiments demonstrate the effectiveness and good generalization ability of the components in the AnatomyNet.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zhu, W., Huang, Y., Tang, H., Qian, Z., Du, N., Fan, W., Xie, X.. 2018-08-16. AnatomyNet: Deep 3D Squeeze-and-excitation U-Nets for fast and fully automated whole-volume anatomical segmentation. https://doi.org/10.1101/392969

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Engineering and characterisation of AAVS1 FRT cell lines for inducible and dose-dependent gene expression

Investigating biological function with high reproducibility requires the generation of stable cell lines that offer precise and inducible transgene expression. However, traditional methods often suffer from the limitations of random genomic integration, including unpredictable expression levels, leaky basal activity, and disruption of endogenous loci. To address these challenges, we engineered a versatile RPE1 cell line by integrating a TetOn3G-FRT cassette into the AAVS1 safe-harbour locus using CRISPR/Cas9(D10A) nickase. This platform utilises the Flp-FRT recombination system to facilitate rapid, site-specific "plug-and-play" insertion of transgenes, combined with the Tet-On 3G system for tight, dose-dependent expression control. The resulting RPE1 AAVS1 FRT8 line enables highly consistent transgene induction across independent clones, behaving as a monoclonal population. We highlight the importance of rigorous cell line characterisation through a multi-omics approach. Whole genome sequencing identified precise heterozygous integration at the target locus and de novo genomic duplications on other chromosomes. By integrating WGS with high-resolution proteomics and cell cycle analysis, we confirmed that these alterations did not significantly perturb cellular homeostasis or phenotypic fitness. This work establishes a robust and reliable platform for the efficient generation of inducible AAVS1 FRT stable cell lines, facilitating reproducible research in modern molecular biology.

bioengineering↗

Raman-probe-derived biomarkers account for cartilage composition, structure, and viscoelastic properties

Raman spectroscopy is an inelastic light scattering technique that reflects the vibrational modes of the biochemical building blocks of the major constituents that comprise the cartilage extracellular matrix (ECM): glycosaminoglycans (GAG), type-II collagen (COL), and water. We investigated whether ECM-specific biomarkers measured with our recently developed arthroscopy-compatible Raman needle probe characterize the functional viscoelastic properties of articular cartilage explants. Equine osteochondral explants were harvested from high-load (femoral condyle) and low-load (intertrochlear groove) sites to evaluate Raman-derived biomarkers of cartilage structure and function. Viscoelastic material properties (equilibrium/dynamic modulus, phase shift) were determined by mechanical indentation. A computational fibril-reinforced biphasic material model was used to estimate the glycosaminoglycan-associated non-fibrillar-matrix modulus, the collagen-associated fibril-network modulus, and hydraulic permeability. Raman-derived biomarkers enabled evaluation of cartilage tissue composition and structure, accounting for 81% of the variation in GAG content, 53% of the variation in COL content, and 58% of the variation in COL anisotropy. Biomarkers also accounted for 81% of the variation in equilibrium modulus, 58% in dynamic modulus, and 51% in phase shift. For poroelastic properties, biomarkers accounted for 83% of the variation in non-fibrillar-matrix modulus, 25% of the variation in fibril-network modulus, and 34% of the variation in hydraulic permeability. Clinical Significance: Raman spectroscopy provides objective compositional biomarkers that account for viscoelastic material properties underlying articular cartilage function. These findings support its future use as an arthroscopic platform for objective assessment of cartilage injury, monitoring of disease progression, and evaluation of therapeutic interventions.

bioengineering↗

An adjuvant for in vivo CAR-T therapy potentiation against solid tumors

In vivo CAR-T therapy offers rapid and controllable T-cell engineering but has yet to achieve durable efficacy against solid tumors. Rather than focusing solely on CAR-T cells, we harness the intact immune system via an in vivo CAR-T adjuvant (iCTA). Composed of aluminum-manganese hydrogel, iCTA can form a spatially confined antigenic and immunostimulatory niche in-situ. By coupling controlled antigen exposure with STING-type I interferon signaling, iCTA not only recruited and reactivated CAR-T cells, but engage the CAR-negative immunocytes with enhanced dendritic-cell antigen presentation and mobilized endogenous antigen-specific T-cell responses. Combined with mRNA-LNP-mediated in vivo CAR-T generation, a single administration of iCTA increased CAR+ T-cell abundance in draining lymph nodes and blood by 2-fold. It also increased T and NK cell infiltration, established an IFNgamma-enriched tumor microenvironment, and reduced exhaustion-associated T-cell states. iCTA improved tumor regression and survival, establishing an adjuvant strategy to enhance in vivo CAR-T therapy.

bioengineering↗