Search bioRxiv⌕ Search

bioRxiv · 10.1101/2025.11.06.686240

Deep learning methods for automated bone segmentation and biomechanical modelling in zebrafish

Abstract

Automated segmentation of three-dimensional micro-computed tomography (CT) scan data is a critical bottleneck in computational morphometrics and biomechanical modelling across musculoskeletal biology. Although advances in imaging have generated increasingly large and complex datasets, manual segmentation remains prohibitively time-consuming, while existing deep learning solutions are often application-specific and rarely validated for their impact on downstream analyses. Here we present a generalisable computational framework for automated segmentation and biomechanical validation of skeletal structures, implemented using an attention-augmented 3D U-Net architecture. Using the adult zebrafish (Danio rerio) mandible as a representative case study, the network was trained on 47 manually segmented specimens and evaluated using a combined Dice-Hausdorff metric that integrates both volumetric and surface accuracy to capture biologically relevant morphology better than Dice score alone. To assess performance in a downstream biomechanical context, we directly compared automated segmentations with those produced by three expert human annotators and constructed finite element models from each. Quantitative comparisons of segmentation accuracy and statistical analyses of finite element outputs demonstrate that automated segmentations perform within the range of expert human annotations, with no systematic bias in mechanical predictions. By explicitly linking geometric accuracy to biomechanical outcomes, this work establishes an end-to-end pipeline for validating automated segmentation in computational biology. The framework will be applicable to a wide range of musculoskeletal and palaeobiological contexts, including comparative anatomy, ageing and disease studies, and fossil or incomplete specimens, where scalable and mechanically faithful segmentation is essential. Author summaryMany studies now use CT scanning to build computer models of bones and test how they perform under load. However, these analyses usually start with manual segmentation, where an expert traces the bone in thousands of image slices to create a 3D surface. This step is time-consuming and introduces uncertainty because experts do not always agree exactly on where boundaries lie. If segmentation changes the model shape, it may also change predicted biomechanics. In this work, we test whether deep learning can automate segmentation while preserving biomechanical outcomes. We train an attention augmented 3D U-Net to segment the adult zebrafish lower jaw and compare its outputs directly to three expert manual segmentations. We assess similarity using complementary measures that reflect both overall overlap and boundary differences. We then build finite element models from each segmentation and compare predicted stress, strain, and displacement distributions. We show that automated segmentations are as consistent as human experts and generate indistinguishable biomechanical predictions, without systematic bias. This supports scalable, repeatable pipelines for linking anatomy to function, and provides a general approach for validating automated segmentation in studies where downstream modelling is the goal.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bowers, F. C., Lane, R., Kawafi, W., Rayfield, E., Paul, D., Pollock, T., Berks, H., Hammond, C. L.. 2025-11-07. Deep learning methods for automated bone segmentation and biomechanical modelling in zebrafish. https://doi.org/10.1101/2025.11.06.686240

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗