Search bioRxiv⌕ Search

bioRxiv · 10.1101/2025.11.06.686240

Deep learning methods for automated bone segmentation and biomechanical modelling in zebrafish

Abstract

Automated segmentation of three-dimensional micro-computed tomography (CT) scan data is a critical bottleneck in computational morphometrics and biomechanical modelling across musculoskeletal biology. Although advances in imaging have generated increasingly large and complex datasets, manual segmentation remains prohibitively time-consuming, while existing deep learning solutions are often application-specific and rarely validated for their impact on downstream analyses. Here we present a generalisable computational framework for automated segmentation and biomechanical validation of skeletal structures, implemented using an attention-augmented 3D U-Net architecture. Using the adult zebrafish (Danio rerio) mandible as a representative case study, the network was trained on 47 manually segmented specimens and evaluated using a combined Dice-Hausdorff metric that integrates both volumetric and surface accuracy to capture biologically relevant morphology better than Dice score alone. To assess performance in a downstream biomechanical context, we directly compared automated segmentations with those produced by three expert human annotators and constructed finite element models from each. Quantitative comparisons of segmentation accuracy and statistical analyses of finite element outputs demonstrate that automated segmentations perform within the range of expert human annotations, with no systematic bias in mechanical predictions. By explicitly linking geometric accuracy to biomechanical outcomes, this work establishes an end-to-end pipeline for validating automated segmentation in computational biology. The framework will be applicable to a wide range of musculoskeletal and palaeobiological contexts, including comparative anatomy, ageing and disease studies, and fossil or incomplete specimens, where scalable and mechanically faithful segmentation is essential. Author summaryMany studies now use CT scanning to build computer models of bones and test how they perform under load. However, these analyses usually start with manual segmentation, where an expert traces the bone in thousands of image slices to create a 3D surface. This step is time-consuming and introduces uncertainty because experts do not always agree exactly on where boundaries lie. If segmentation changes the model shape, it may also change predicted biomechanics. In this work, we test whether deep learning can automate segmentation while preserving biomechanical outcomes. We train an attention augmented 3D U-Net to segment the adult zebrafish lower jaw and compare its outputs directly to three expert manual segmentations. We assess similarity using complementary measures that reflect both overall overlap and boundary differences. We then build finite element models from each segmentation and compare predicted stress, strain, and displacement distributions. We show that automated segmentations are as consistent as human experts and generate indistinguishable biomechanical predictions, without systematic bias. This supports scalable, repeatable pipelines for linking anatomy to function, and provides a general approach for validating automated segmentation in studies where downstream modelling is the goal.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bowers, F. C., Lane, R., Kawafi, W., Rayfield, E., Paul, D., Pollock, T., Berks, H., Hammond, C. L.. 2025-11-07. Deep learning methods for automated bone segmentation and biomechanical modelling in zebrafish. https://doi.org/10.1101/2025.11.06.686240

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Synergy-informed bilevel optimization reveals joint-specific benefits for realistic exoskeleton torque prediction

Simulation-driven optimization can guide exoskeleton control design, but its utility is limited by the accuracy with which muscle coordination is predicted. Strict effort-minimization formulations predict non-physiological muscle shutdown under high exoskeleton assistance, leading to peak assistive torques that exceed values reported in human-in-the-loop experiments. We evaluated the accuracy of synergy-informed simulations at predicting assistance across four single-joint exoskeleton configurations: ankle plantarflexion, knee extension, hip flexion, and hip abduction. We implemented a bilevel optimization to predict a parameterized assistive torque that minimizes metabolic cost, with assisted muscle dynamics estimated via either effort-minimization simulations (minimizing muscle effort only) or synergy-informed simulations (minimizing muscle effort constrained to a synergy structure). We used experimental data from five unimpaired adults walking at their preferred speed and compared results descriptively between the two formulations within each subject. Assistance based on effort-minimization simulations shut down agonist muscle activations and overestimated peak assistive torque compared with experimental values. In contrast, constraining muscle controls to a synergy structure prevented non-physiological muscle shutdown and yielded assistive torques closer to those measured in human-in-the-loop experiments. This benefit was not observed equally across all assisted degrees of freedom or subjects, emerging only where no single synergy could be suppressed to unload the assisted muscles. Synergy weights can therefore be interpreted as joint-specific predictors of when simulations can reliably inform wearable robot design.

bioengineering↗

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗