Search bioRxiv⌕ Search

bioRxiv · 10.1101/2025.10.26.684645

Enhancing HIPEC for Ovarian Cancer using Adjunctive Biomaterials

Abstract

Ovarian cancer is one of the most lethal gynecological malignancies, with high mortality rates primarily due to late-stage diagnoses and extensive peritoneal metastases. Despite improvements in surgical and chemotherapeutic treatments, the prognosis for advanced ovarian cancer remains poor, highlighting the urgent need for innovative therapeutic approaches. Hyperthermic intraperitoneal chemotherapy (HIPEC) has emerged as a promising treatment, delivering heated chemotherapeutic agents directly into the peritoneal cavity post-cytoreductive surgery. However, HIPEC adoption is limited by three critical complications: suboptimal therapeutic efficacy in resistant tumors; abdominal adhesion formation; and systemic toxicity, including cisplatin-induced nephrotoxicity. This study investigates carbon monoxide gas- entrapping materials (CO-GEMs) as a novel multifunctional adjunctive therapy to address the three HIPEC limitations simultaneously. CO-GEMs effectively encapsulate and deliver carbon monoxide, leveraging the differential effects of CO in cancerous where it has been shown to reduce tumor burden. In ovarian cancer models, CO-GEMs significantly enhanced cisplatin efficacy, reducing the metastatic tumor burden by 46.6% through the downregulation of drug resistance pathways, including the IL-17, TNF, and NF-{kappa}B pathways; ECM receptor interaction, and VEGF signaling. CO-GEMs also prevented peritoneal adhesion formation by suppressing inflammatory cell infiltration and collagen deposition, with a significant reduction in adhesion severity scores. Additionally, enteral CO-GEMs provided significant nephroprotection against cisplatin-induced acute kidney injury, as demonstrated by reduced blood urea nitrogen levels. CO-GEMs represent a promising innovation that simultaneously improves HIPEC therapeutic efficacy, prevents surgical complications, and reduces systemic toxicity. This multifunctional approach addresses multiple clinical limitations of HIPEC, potentially transforming treatment outcomes for patients with advanced ovarian cancer through an enhanced therapeutic index and improved safety profile.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bi, J., Witt, E., Cafi, A. B., Shu, F., McGovern, M., Tunuguntla, S. N. S., Balk, K. R., Boge, L., Wang, Q., Du, J., Sutton, I. C., Reis, C. J., Spreng, J. M., Elizalde, E., Uzomah, U., Traverso, G., Otterbein, L. E., Byrne, J.. 2025-10-27. Enhancing HIPEC for Ovarian Cancer using Adjunctive Biomaterials. https://doi.org/10.1101/2025.10.26.684645

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Impaired loading following denervation elicits dynamic, differential growth trajectories of musculoskeletal tissues

Physical forces dictate the function and maintenance of adult musculoskeletal tissues. Yet, the impact of biophysical cues on the growth and maturation of these tissues, especially dense connective tissues, remains unclear. Here, we investigated the effects of neonatal mechanical loading on early postnatal growth of the musculoskeletal tissues of the lower limb, with particular focus on the Achilles tendon. We performed sciatic nerve resection (SNR) on one-day-old mice to denervate the hamstrings and distal hindlimb muscles. Sciatic Nerve Resection resulted in severe and sustained alterations in gait, accompanied by an altered transcriptional landscape in distal musculoskeletal tissues, with marked reductions in bone and tendon growth and smaller, fibrotic hindlimb musculature. Sciatic nerve resection impaired cumulative growth in the Achilles tendon, shifting cell proliferation and matrix-driven growth trajectories and altering mechanotransduction gene programs toward inflammation and matrix catabolism with age. This work highlights the essential role of mechanical loading in driving mechanosignaling and postnatal growth trajectories in musculoskeletal tissues of the developing limb, with implications for overall musculoskeletal health in adulthood.

bioengineering↗

MiniMAP: An automatic pipeline for paediatric lower limb musculoskeletal model generation

The generation of paediatric musculoskeletal models often requires compromise between data availability, accuracy, and computation time. Statistical shape models allow for rapid generation of bone geometries for use in musculoskeletal modelling. An articulated shape model allows for movement at the joints during optimisation to better fit to experimental data. Here we present a methodology for generating custom paediatric OpenSim models using an articulated shape model of the lower limb generated from CT scans of over 300 children aged 4 to 18 years old. Bone geometries are predicted using demographic factors (age, height, mass, and sex), linear bone measurements (bone widths and lengths), and 12 skin surface landmarks (L/R ASIS, L/R PSIS, medial/lateral epicondyles, and medial/lateral malleoli). To account for skin padding (bone to skin surface distance) a random forest algorithm was developed for skin padding prediction for these 12 landmarks. Accuracy of the model prediction was assessed using a leave-one-out analysis to assess landmark errors, bone surface errors, and clinical bone measurement errors (linear measurements and angular values). Motion capture and MRI data were collected from two paediatric test cases to test the workflow on unseen data. Skin padding values varied widely in this population with average values from 3.4mm at the lateral malleolus to 25.9mm at the PSIS. Skin padding was best predicted using age, height, mass, ASIS width, epicondylar width, and malleolar width with an average RMSE of 4.68mm. The articulated shape model predicted accurate bone geometries from skin surface landmarks with average bone surface RMSEs of 2.64 {+/-} 0.99mm, 1.91 {+/-} 0.59mm, and 1.69 {+/-} 0.56mm in the pelvis, femora, and tibiae/fibulae respectively. In the two unseen test cases, average bone surface errors ranged from 1.64 {+/-} 1.2mm to 3.41 {+/-} 3.1mm. This study demonstrated the accuracy of "MiniMAP", for the rapid generation of custom paediatric musculoskeletal models.

bioengineering↗

A single-plane electrical impedance tomography framework for integrated liver and kidney assessment

Chronic liver and kidney diseases frequently coexist, but their assessment typically requires separate clinical workflows involving serum-based estimated glomerular filtration rate (eGFR) testing and liver elastography-based controlled attenuation parameter (CAP). Electrical impedance tomography (EIT) has recently shown promise for providing portable, non-invasive proxies for both reference measurements. However, existing multi-organ EIT assessment still requires different acquisition protocols for each organ. To simplify this procedure, we assessed the feasibility of a single-plane EIT framework for reconstructing organ-specific images and estimating liver and kidney health from one abdominal belt placement. Across diverse abdominal belt locations, opposite-plane deviation was significantly greater for eGFREIT estimates (2.92%; IQR, 0.46-12.53%) than for CAPEIT estimates (0.94%; IQR, 0.66-1.70%) (p < 0.01). For both organs, compared to images acquired at the conventional organ-specific planes, image correlation significantly decreased (both, p < 0.05) and normalized root mean squared error significantly increased (both, p < 0.05) at the furthest imaging plane, with these differences being numerically larger for the kidney. Together, these results supported the kidney plane as the preferred location for multi-organ assessment. Test-retest evaluation after belt removal and reapplication demonstrated that the correlation between two repeated CAPEIT estimates was just as strong at the kidney plane (R2 = 0.98, p < 0.001) as it was at the conventional liver plane (R2 = 0.97, p < 0.001). Finally, in an independent clinical cohort, kidney-plane CAPEIT estimates were significantly higher in participants with a high metabolic liver-risk profile (i.e. diabetes and high blood pressure) (p < 0.005). CAPEIT estimates also distinguished high and low metabolic risk groups with an AUC of 0.756. Together, these findings support the feasibility of a portable multi-organ EIT imaging framework capable of extracting complementary liver and kidney information from a single belt placement.

bioengineering↗