Search bioRxiv⌕ Search

bioRxiv · 10.1101/2025.09.08.674827

Optimizing Electrotactile Stimulation Parameters for Responses Under Cognitive Load

Abstract

AO_SCPLOWBSTRACTC_SCPLOWO_ST_ABSBackgroundC_ST_ABSProsthetic users mainly rely on their vision for feedback during control of the device in absence of the tactile and proprioceptive modalities. Overreliance on vision increases cognitive load during prosthesis use, resulting in reduced control performance. Provision of additional feedback through other modalities could reduce this overreliance on vision and improve closed-loop prosthetic control. Fast and accurate recognition of feedback is particularly important when we consider that both delays and inaccuracies can destabilize closed-loop control environments. Transcutaneous electrotactile stimulation is a promising technology with advantages including non-invasiveness and simplicity. It is not yet clear, however, which parameters influence the speed and accuracy of response to electrotactile stimuli. In this study, we set out to investigate how we can influence response characteristics to an instantaneous change in stimulation intensity by manipulating both stimulus-related and environmental variables. Methods20 participants completed a randomized reaction time test to both visual and electrotactile stimulation. Participants were asked to respond to incoming stimuli with a button press on a controller as fast as possible, without discriminating between modality of stimulation. In a second experiment, 20 participants completed an intensity discrimination task for electrotactile stimulation. Participants had to prioritize either speed or accuracy during specific blocks, while cognitive load, magnitude of intensity shift and direction of shift were manipulated. ResultsThe results of the reaction time experiment confirmed lower average response times for electrotactile stimuli compared to visual stimuli by a median of ~50ms (p=0.008). In the intensity discrimination experiment, increased shift intensities led to increased response accuracies and decreased response times (p<0.001 in both cases). The presence of cognitive load increased average response times (p=0.005), but did not affect response accuracies (p=0.420). ConclusionsThe results of the intensity discrimination experiment imply that the magnitude of intensity shift needs to be provided via steps multiple times larger than the just noticeable difference to ensure fast and accurate responses to electrotactile stimulation. Moreover, results from the reaction time experiment confirmed faster average response times for electrotactile stimuli over visual stimuli. We argue that providing electrotactile stimulation using bigger steps in perceived intensity could result in the supplementary feedback making closed-loop control of prosthetic devices more reliable.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jarto, F., Corbett, E. A., Dupan, S.. 2025-09-12. Optimizing Electrotactile Stimulation Parameters for Responses Under Cognitive Load. https://doi.org/10.1101/2025.09.08.674827

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

CoReg, tracking-based motion compensation for in vivo calcium imaging

In vivo calcium imaging enables the observation of neural activity with high spatial and temporal resolution. However, recordings are frequently affected by motion artifacts caused by animal movement, physiological processes, tissue drift, or instability of the imaging setup. These artifacts make signal extraction harder and reduce the consistency of downstream analyses. Current registration methods can correct rigid and non-rigid motion, but often estimate motion from individual frames or image patches and make limited use of temporal information. In addition, activity-driven fluorescence changes can make it difficult to distinguish changes in image appearance from actual motion. Here, we treat motion correction in calcium imaging as a point tracking problem and introduce CoReg, an open-source Python- based software tool with a graphical user interface. We benchmark CoReg against established registration methods using fluorescence imaging datasets from multiple species. CoReg performs competitively with or better than existing approaches across several settings. We further show that its performance is robust to the choice of tracked points, making the method straightforward to apply. CoReg includes implementations of both our method and the evaluated established methods. Our results show that tracking-based registration provides a simple and reliable approach for motion correction in vivo calcium imaging.

neuroscience↗

A shared slowing axis and phenotype-specific rhythms link clinical EEG to FDG-PET dementia phenotypes

Early and accurate identification of neurodegenerative disorders has notable implications for treatment and quality of life. Whereas neuroimaging-based biomarkers can accurately identify neurodegenerative subtypes, EEG represents a low-cost alternative that could expand access to dementia care. Here, we investigated whether six data-driven EEG latent factors, derived by nonnegative tensor decomposition of clinical EEGs, differ systematically across FDG-PET-defined neurodegenerative phenotypes. In 455 patients with EEG and FDG-PET acquired within one year of each other, factor expression was compared across 14 diagnostic classes assigned by StateViewer, a validated artificial intelligence framework for FDG-PET interpretation. To separate disease-general severity from phenotype-specific topography, each factor was also regressed on a subject-level slowing index. Finally, we related the factors to regional FDG uptake and to neuropsychological performance (n = 98) and assessed their potential utility for single-subject classification. Four factors reflecting neurophysiological oscillations (posterior alpha, Rolandic beta, frontotemporal delta-theta and posterior theta-slow alpha) varied significantly across phenotypes, with attenuation of faster and augmentation of slower rhythms most pronounced in dementia with Lewy bodies (DLB), dysexecutive Alzheimer disease (AD) and posterior cortical atrophy, whereas factors dominated by eye-movement and muscle artifact showed no robust phenotypic association. Alpha and beta effects were largely attributable to overall slowing, whereas posterior theta-slow alpha became more phenotype-specific after adjustment (eta-squared 0.082 to 0.147), dissociating the Alzheimer disease spectrum from frontotemporal syndromes. The slowing index tracked with an FDG-PET pattern highly associated with DLB across the cohort, irrespective of assigned phenotype (r = 0.51, P < 0.001). Consistent with a model in which dementia phenotypes reflect altered hippocampal-neocortical oscillatory coupling (stochastic latent oscillatory diffusion), frontotemporal delta-theta tracked a limbocortical axis of metabolic pattern expression, rising with neocortical and falling with limbic-predominant involvement, independent of overall slowing and phenotype. Each factor mapped onto a distinct metabolic topography, with frontotemporal delta-theta resembling Alzheimer-type hypometabolism and posterior theta-slow alpha the medial occipital hypometabolism of DLB. In terms of neuropsychological performance, Rolandic beta was associated with executive functions, and frontotemporal delta-theta with memory, visuospatial and global performance. Using these four factors alone, an exploratory logistic regression classifier separated cognitively unimpaired participants from DLB, posterior cortical atrophy, typical AD, and dysexecutive AD (area under the curve > 0.8) but poorly discriminated frontotemporal dementia phenotypes canonically associated with 4-repeat tau. Thus, data-driven decomposition of clinical EEG separates oscillatory activity from artifact into factors that track metabolic phenotype, regional metabolism and cognition, capturing both overall slowing and phenotype-specific patterns. This work informs the further development of scalable, biology-informed EEG-based phenotyping of neurodegenerative disease.

neuroscience↗

An application of fNIRS for the prediction of hearing thresholds in sleeping infants: a proof of principle

This study applied a two-component-response modelling approach to fNIRS recordings obtained from naturally sleeping infants presented with auditory stimuli at different sound intensities. We investigated whether the relationship between fNIRS response measures and stimulus intensity could be modelled to estimate individual auditory hearing thresholds. In the normal-hearing group, 75% of infants had threshold estimates for the sound /ba/ within the expected normal-hearing range, with an estimated mean equivalent normal loudness (ENL) of 10.72 dB HL (SD 8.64 dB HL). A case study further explored the potential application of this approach in an infant with hearing impairment, highlighting the importance of reliable responses at lower stimulus intensities and appropriate regression model selection. These findings provide preliminary evidence that cortical haemodynamic responses can be quantitatively related to sound intensity for estimating auditory sensitivity.

neuroscience↗