Search bioRxiv⌕ Search

bioRxiv · 10.1101/2025.07.24.666548

Quantitative and unbiased lung alveolar septum assessment in a LPS experimental mouse model using 2D-spatial correlation image analysis from hematoxylin and eosin slides.

Abstract

Quantitative assessment of lung tissue architecture is essential for evaluating disease progression in experimental models of acute lung injury (ALI). However, conventional methods for measuring alveolar septum (tabique) thickness rely on manual annotation, which is time-consuming and observer-dependent, compromising comparability and reproducibility. In this study, we introduce a novel, fully automated approach based on two-dimensional spatial autocorrelation function (2D-ACF) analysis to quantify septum thickness from hematoxylin and eosin (H&E)-stained lung tissue sections. After validating the method with a simulated data set, the new approach was applied to a murine model of Acute Lung Injury (ALI) induced by intratracheal instillation of lipopolysaccharide (LPS), under two dietary conditions: normal (ND) and high-fat diet (HFD), thereby testing our approach with a double hit protocol for ALI development. The 2D-ACF analysis provided a robust metric of structural organization, allowing for an unbiased estimation of mean septum thickness across entire tissue images. Compared to controls, LPS instillation increased septal thickness more than six-fold, with further thickening observed in the HFD+Instilled group. These findings were consistent across >400 images and captured subtle additive effects of metabolic stress on lung injury. Traditional manual measurements of septum thickness exhibited substantial inter-observer variability, particularly in the LPS-instilled group, where structural heterogeneity made consistent interpretation challenging. This subjectivity limits the reproducibility of histopathological evaluations, especially under pathological conditions with subtle anatomopathological differences. In contrast, the 2D-ACF method offered a standardized and observer-independent approach. A direct comparison between methods revealed a strong and statistically significant correlation in the instilled group (r = 0.89, p < 0.001), indicating that the 2D-ACF captures key structural features aligned with expert assessments while reducing user bias. In summary, the 2D-ACF framework offers a powerful alternative to conventional image analysis for studying lung pathology. Its adaptability to different experimental settings and potential to be extended to other tissues with spatial heterogeneity makes it a valuable tool for translational biomedical research and digital pathology.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lopassio, M., Garcia, M. J., Malacrida, L. S.. 2025-07-27. Quantitative and unbiased lung alveolar septum assessment in a LPS experimental mouse model using 2D-spatial correlation image analysis from hematoxylin and eosin slides.. https://doi.org/10.1101/2025.07.24.666548

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Design of colipids with controlled lateral distance of head group moieties for targeting strategies in the field of lipid-based nanoparticles

Lipid nanoparticles and liposomes are nanoparticle drug formulations which are firmly established in clinics. In order to expand their application and improve efficacy, surface modifications can be a key strategy, especially for cell specific targeting. Targeting can be achieved by integrating ligand functionalized lipids or lipidoids on the nanoparticle surface. In this case, not solely the targeting ligand itself, but also the structure of the whole targeting lipid/lipidoid can affect the interaction of the targeting ligand with the binding motive on cells. Especially, distal spacer structures between lipid anchor and ligand unit, often composed of polyethylene glycol chains, provide a certain distance of the ligand from the nanoparticle surface. A concept which is currently neglected is the control of the lateral distance between ligand structures on the nanoparticle. Herein we investigated the possibility to design lipidoids with a lateral spacer composed of polyethylene glycol units. We synthesized and characterized different lipidoids which provide a primary amine in the head group for possible ligand coupling. In our model lipidoids the head groups were functionalized with a paramagnetic probe to apply electron paramagnetic resonance (EPR) methods for the characterization of the lipidoid interaction with model nanoparticles, in our case liposomes. Continuous wave EPR was used to study the efficiency of the novel lipidoids to integrate into lipid bilayers of model liposomes, which was shown to depend on lipidoid structure and liposome composition. Furthermore, using double electron-electron resonance (DEER), we observed lipidoid conformational changes occurring upon integration into liposomes.

biophysics↗

Beyond Sequence and Structure: Pretraining PLMs on Continuous Biophysical Fields

We introduce the Biophysical Transformer, a protein language model that adds continuous biophysical fields as a third pretraining signal beside sequence and structure. A Poisson-Boltzmann solver computes the electrostatic potential around each three-residue token, and the model learns to predict it from sequence alone. A rotationally invariant spherical-harmonic descriptor serves as the loss target, eliminating the need for frame alignment during training and for coordinates at inference. Against a matched, one-flag control on the FLIP Meltome thermostability benchmark, the field objective raises Spearman correlation on every trained head of both human splits.The gain on human survives residualizing dipeptide composition under two architecturally different readouts and survives removing the test proteins that overlap the pretraining corpus. No effect survives on the organism-mixed split. At 1.1M parameters, both the Biophysical Transformer and its sequence-only control exceed FLIP's one-hot CNN and untrained-ESM baselines on every split. All results rest on a single pretraining run per arm,and the current design does not separate field content from generic regularization.

biophysics↗

An auditable harness for biomolecular dynamics simulations by AI agents

AI agents now generate biological hypotheses faster than they can be tested. Hypotheses stated at the atomic level can be examined with molecular dynamics (MD) simulations. For new questions without a reference, trust in an agent-run simulation rests on a tool-written process record, not the agent's account. Existing MD agents leave this record to the language model. Here we present MDClaw, a harness whose validating tools and directed acyclic graph (DAG) check stages before execution and record every simulation stage. On MDDataBench, which grades outputs against deposited simulations, four open-weight models with MDClaw passed all three runs on 81-100% of 31 test systems. The DAG complements this outcome check. An ablation without the DAG revealed 11 successful runs that had skipped minimization or equilibration, or simulated a different structure. MDClaw carried questions from human and AI scientists through simulation to trajectories traceable to their inputs and settings.

biophysics↗