Search bioRxiv⌕ Search

bioRxiv · 10.1101/2025.07.11.664411

Non-invasive Free-breathing Gating-free Extracellular Cellular Volume Quantification for Repetitive Myocardial Fibrosis Evaluation in Rodents

Abstract

BackgroundInterstitial myocardial fibrosis is a crucial pathological feature of many cardiovascular disorders. Myocardial fibrosis resulting in extracellular volume (ECV) expansion can be non-invasively quantified by cardiac MRI (CMR) with T1 mapping before and after gadolinium (Gd) contrast agent administration. However, longitudinal repetitive ECV measurements are challenging in rodents due to the prolonged scan time with cardiac and respiratory gating that is required for conventional T1 mapping and the invasive nature of the rodent intravenous lines. MethodsTo address these challenges, the objective of this study is to establish a fast, free- breathing, and gating-free ECV procedure with a non-invasive subcutaneous catheter for in- scanner Gd administration that can allow longitudinal repetitive ECV evaluations in rodent models. This is achieved by (1) IntraGate sequence for free-breathing gating-free cardiac imaging, (2) non-invasive subcutaneous in-scanner Gd administration, and (3) fast T1 mapping with varied flip angle (VFA) in conjunction with (4) triple jugular vein blood T1 normalization. Additionally, full cine CMR (multi-slice short-axis, long-axis 2-chamber, and long-axis 4- chamber) was acquired during the waiting period for comprehensive systolic cardiac functional and strain analysis. ResultsWe have successfully established a non-invasive fast ECV quantification protocol to enable longitudinal repetitive ECV quantifications in rodents. Non-invasive subcutaneous Gd bolus administration induced reasonable dynamic contrast enhancement (DCE) time course reaching a steady state in [~] 20 min for stable T1 quantification. The free-breathing gating-free VFA T1 quantification scheme allows for rapid cardiac ([~]2.5 min) and jugular vein (49 sec) T1 quantification with no motion artifacts. The triple jugular vein T1 acquisitions (1 pre-contrast and 2 post-contrast) immediately flanking the heart T1 acquisitions enable accurate myocardial ECV quantification. Our data demonstrated that left-ventricular myocardial ECV quantifications were highly reproducible with repeated scans, and the ECV values (0.25) are comparable to reported ranges among humans and rodents. This protocol was successfully applied to ischemic reperfusion injury model to detect myocardial fibrosis that was validated with histopathology. ConclusionWe have established a simple, fast, non-invasive, and robust CMR protocol in rodents that can enable longitudinal repetitive ECV quantifications for cardiovascular disease progression. It can be used to monitor disease regression with interventions. Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=136 SRC="FIGDIR/small/664411v1_ufig1.gif" ALT="Figure 1"> View larger version (33K): org.highwire.dtl.DTLVardef@14b44e5org.highwire.dtl.DTLVardef@985392org.highwire.dtl.DTLVardef@96cef7org.highwire.dtl.DTLVardef@ede47d_HPS_FORMAT_FIGEXP M_FIG C_FIG

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Cortes, D. R. E., Becker-Szurszewski, T., Hartwick, S., Amjad, M. W., Mohammed, S. A., Chen, X., Pacella, J. J., Christodoulou, A. G., Wu, Y.. 2025-07-17. Non-invasive Free-breathing Gating-free Extracellular Cellular Volume Quantification for Repetitive Myocardial Fibrosis Evaluation in Rodents. https://doi.org/10.1101/2025.07.11.664411

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Ferrybots: Programmable Hydrogel Microbots for Rapid Magnetic Navigation and Modular Function

Untethered microrobots could enable localized delivery, sensing, and intervention in confined biological and engineered environments. Magnetic actuation is especially attractive for such systems because it provides remote, fuel-free control, but practical magnetic microrobots remain difficult to manufacture and functionalize. High magnetic loading can interfere with polymerization and structural integrity, while integrating application-specific payloads directly into the robot body often requires the entire material formulation to be redesigned. Here, we introduce Ferrybots, programmable hydrogel microrobots that physically separate magnetic navigation from functional cargo. An automated droplet-on-demand microfluidic flow-lithography process confines high-concentration ferrofluid cores within photopolymerized poly (ethylene glycol) diacrylate (PEGDA) structures, enabling magnetic loading to be programmed through core number and spacing without uniformly dispersing magnetic particles throughout the hydrogel. The process achieved a minimum fabrication cycle time of 15 s. Ferrybots exhibited magnetic-dose-dependent translation and rotation, branched-channel steering, out-of-plane obstacle traversal, and rapid translation, with two-core robots following an external magnet at speeds up to the 9000 mm/min limit of the actuation system. Differences in magnetic loading also enabled sequential selective navigation of distinct Ferrybot populations. Using PEGDA 575 as a common interface material, independently formulated hydrogel cargo modules could subsequently be fused to preformed Ferrybots while preserving navigation. Separately, cargo modules enabled composition-dependent molecular release and oxygen-responsive sensing through 1-mm-thick skin-mimicking optical phantoms representing a broad range of skin types. By decoupling locomotion from function, Ferrybots provide a common magnetic vehicle that can be combined with interchangeable delivery, sensing, or responsive-material modules, offering a general strategy for rapidly adapting microrobots to different applications.

bioengineering↗

Circular-Arc Modal Migration for Ultrasound Imaging--Part I: Finite-Arc Spectral Theory and Stolt-Pullback Factorization

Circular-arc ultrasound imaging requires a spectral construction that accommodates radius-dependent propagation and the spatially varying phase of offset-source transmission. This first of two articles develops Circular-Arc Modal Migration (CAMM), a direct Stolt-type imaging framework in angular modal coordinates. Starting from a first-Born acoustic model, angular decomposition and local radial Stolt mappings convert channel spectra into fields for coherent image synthesis. The offset transmit phase is represented by a phase-screen factorization through reusable spectral factors and spatially weighted fields. A scalar-pullback approximation simplifies this correction to reading one reference image at a geometrically fitted radial coordinate. Both realizations share the same modal construction. Error controls address local radial synthesis, transmit-path expansion, scalar approximation, and phase-screen truncation, with direct integration verifying the separated numerical evaluation. Same-RF point-target comparisons show that scalar pullback closely preserves the principal peak positions and widths of phase-screen imaging in the compact semicircular configuration, while phase screens better control surrounding responses in the shallow convex examples. The retained modal spectrum, frequency band, image radius, and source displacement guide this accuracy--computation choice. CAMM thereby extends direct spectral image formation to circular arcs and supplies the theoretical and numerical basis for the image-quality and performance studies in Part~II.

bioengineering↗

Identification and isolation of migratory subpopulations of cancer cells using microfluidics with fluid walls

Microfluidic assays have great potential for investigating cancer cell migration, a key process underlying metastasis which remains a major clinical challenge. However, adoption by biologists is limited due to complex fabrication and operation methods combined with difficulty in retrieving cells of interest. We jet-print dumbbell-shaped microfluidic environments with fluid walls in standard Petri dishes in seconds using standard growth media and immiscible oil. Prostate cancer cells and chemoattractant (bovine serum) are introduced into each end using local transient differences in Laplace pressure to enable spatial confinement. Automated live-cell imaging monitors chemotaxis towards serum using standard microscopes, as the confining fluid walls are optically transparent. Distinct subpopulations of migratory cells exhibit different morphologies and motilities, assessed using a custom machine-learning segmentation model. Then, we leverage the reconfigurability of fluid walls to isolate and retrieve rapidly-migrating single cells. This demonstrates that fluid-walled microfluidics is a versatile and accessible approach for investigating cancer cell migration at single-cell resolution, offering new opportunities to examine cellular heterogeneity in metastasis.

bioengineering↗