Search bioRxiv⌕ Search

bioRxiv · 10.1101/2025.07.11.664411

Non-invasive Free-breathing Gating-free Extracellular Cellular Volume Quantification for Repetitive Myocardial Fibrosis Evaluation in Rodents

Abstract

BackgroundInterstitial myocardial fibrosis is a crucial pathological feature of many cardiovascular disorders. Myocardial fibrosis resulting in extracellular volume (ECV) expansion can be non-invasively quantified by cardiac MRI (CMR) with T1 mapping before and after gadolinium (Gd) contrast agent administration. However, longitudinal repetitive ECV measurements are challenging in rodents due to the prolonged scan time with cardiac and respiratory gating that is required for conventional T1 mapping and the invasive nature of the rodent intravenous lines. MethodsTo address these challenges, the objective of this study is to establish a fast, free- breathing, and gating-free ECV procedure with a non-invasive subcutaneous catheter for in- scanner Gd administration that can allow longitudinal repetitive ECV evaluations in rodent models. This is achieved by (1) IntraGate sequence for free-breathing gating-free cardiac imaging, (2) non-invasive subcutaneous in-scanner Gd administration, and (3) fast T1 mapping with varied flip angle (VFA) in conjunction with (4) triple jugular vein blood T1 normalization. Additionally, full cine CMR (multi-slice short-axis, long-axis 2-chamber, and long-axis 4- chamber) was acquired during the waiting period for comprehensive systolic cardiac functional and strain analysis. ResultsWe have successfully established a non-invasive fast ECV quantification protocol to enable longitudinal repetitive ECV quantifications in rodents. Non-invasive subcutaneous Gd bolus administration induced reasonable dynamic contrast enhancement (DCE) time course reaching a steady state in [~] 20 min for stable T1 quantification. The free-breathing gating-free VFA T1 quantification scheme allows for rapid cardiac ([~]2.5 min) and jugular vein (49 sec) T1 quantification with no motion artifacts. The triple jugular vein T1 acquisitions (1 pre-contrast and 2 post-contrast) immediately flanking the heart T1 acquisitions enable accurate myocardial ECV quantification. Our data demonstrated that left-ventricular myocardial ECV quantifications were highly reproducible with repeated scans, and the ECV values (0.25) are comparable to reported ranges among humans and rodents. This protocol was successfully applied to ischemic reperfusion injury model to detect myocardial fibrosis that was validated with histopathology. ConclusionWe have established a simple, fast, non-invasive, and robust CMR protocol in rodents that can enable longitudinal repetitive ECV quantifications for cardiovascular disease progression. It can be used to monitor disease regression with interventions. Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=136 SRC="FIGDIR/small/664411v1_ufig1.gif" ALT="Figure 1"> View larger version (33K): org.highwire.dtl.DTLVardef@14b44e5org.highwire.dtl.DTLVardef@985392org.highwire.dtl.DTLVardef@96cef7org.highwire.dtl.DTLVardef@ede47d_HPS_FORMAT_FIGEXP M_FIG C_FIG

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Cortes, D. R. E., Becker-Szurszewski, T., Hartwick, S., Amjad, M. W., Mohammed, S. A., Chen, X., Pacella, J. J., Christodoulou, A. G., Wu, Y.. 2025-07-17. Non-invasive Free-breathing Gating-free Extracellular Cellular Volume Quantification for Repetitive Myocardial Fibrosis Evaluation in Rodents. https://doi.org/10.1101/2025.07.11.664411

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Wall stiffening is a primary contributor to motility loss in Crohn's disease: an electromechanical modeling study

Fibrotic strictures are among the most disabling complications of Crohn's disease, permanently narrowing the bowel and impairing motility, yet no approved therapy reverses them. Chronic inflammation alters pacemaker-network coupling, smooth-muscle excitability, and calcium-dependent contractility, while fibrosis thickens the bowel wall, narrows the lumen, and changes tissue mechanics. The relative contributions of these coupled electrical, contractile, and structural alterations to motility loss remain unclear. To address this gap, we develop an integrated electromechanical finite-element framework for fibrostenosing Crohn's disease that couples a fibrosis-driven growth model with a FitzHugh-Nagumo electromechanical model. A full-factorial 25 design of experiments is used to quantify the relative effects of electrical diffusivity, excitation threshold, peak active stress, wall stiffness, and hypertrophic remodeling on cyclic lumen-volume deformation. Motility is quantified by the standard deviation of lumen volume over one contraction cycle. Within the parameter ranges examined, increased wall stiffness emerged as the dominant contributor to motility loss, followed by impaired smooth-muscle contractility. Changes in excitation threshold, hypertrophic remodeling, and electrical diffusivity produced substantially smaller effects. Pairwise interactions were small relative to the dominant main effects, indicating that the mechanisms contributed largely through their individual effects. Our findings suggest that limiting wall stiffening while preserving smooth-muscle contractile function may provide a therapeutic strategy for maintaining intestinal motility in fibrostenosing Crohn's disease.

bioengineering↗

Lactate Receptor Activation Alleviates Senescence and Preserves Homeostasis of Aged Arteries

Arteries are among the first tissues to exhibit age-related dysfunction, yet the metabolic mechanisms driving vascular senescence remain poorly understood. Here, analysis of human aortic transcriptomic data identified HCAR1, encoding the lactate receptor GPR81, as one of the genes most significantly downregulated with age. We therefore investigated whether age-associated loss of GPR81 contributes to cellular senescence within the vessel wall. Senescent human endothelial cells and vascular smooth muscle cells accumulated neutral and oxidized lipids and exhibited increased labile iron and ferroptosis. Silencing GPR81 in early-passage cells recapitulated this metabolic phenotype together with multiple hallmarks of cellular senescence. Moreover, endothelial-specific deletion of GPR81 in young mice was sufficient to induce senescent cell accumulation, impaired lipid homeostasis, endothelial dysfunction, and elastin disorganization. Conversely, pharmacological activation of GPR81 with the agonist CHBA restored fatty acid metabolism, promoted glycolytic reprogramming, and attenuated ferroptotic stress and senescence-associated phenotypes. In lamin A knock-in (LAKI) progeroid mice, CHBA reduced arterial lipid accumulation and cellular senescence, shifted vascular cell composition toward a youthful state, improved endothelial integrity, and restored extracellular matrix homeostasis. Together, these findings identify age-associated loss of GPR81 as a driver of vascular metabolic dysfunction and cellular senescence and establish pharmacological GPR81 activation as a promising therapeutic strategy for preserving vascular homeostasis and mitigating age-associated cardiovascular disease.

bioengineering↗

Targeted and bilateral blood flow monitoring in middle cerebral artery using diffuse correlation spectroscopy

Objective: To develop and validate a dual-probe Diffuse Correlation Spectroscopy (DCS) system for non-invasive and simultaneous, monitoring of cerebral blood flow (CBF) in the bilateral Middle Cerebral Artery (MCA) territories, and expanding the utility of conventional DCS limited to cortical-volume-based CBF measurements to vessel-specific cerebral perfusion monitoring. Methods: A dual-probe DCS system was designed for non-invasive monitoring of MCA-specific perfusion. Probe placement and protocol optimization study has been performed using anatomical landmarks, motor and speech activation tasks in healthy volunteers. System stability and repeatability were further evaluated in a pilot cohort of 30 healthy (age, 25{+/-}7 years) participants using optimized probe position and protocol. A bilateral MCA ischemic Lacunar Infract stroke case report also validated the feasibility of the system in clinical settings. Results: Measurements demonstrated superior sensitivity towards MCA-territory perfusion at targeted probe locations compared to off-MCA positions. In pilot cohort, significant increase of 30.34 {+/-} 21.56% and 36.48 {+/-} 21.22% in rCBF corresponding to hand squeeze and speech task respectively showed reproducible physiological responsiveness of the system (p<0.001). Measurement done on a patient with bilateral MCA ischemic Lacunar Infract stroke showed a significant change of 30% during speech for both the MCAs but no significant change is observed for hand squeeze tasks. Conclusion: The custom built dual-probe DCS system enables non-invasive, operator-independent, targeted and continuous monitoring of rCBF within bilateral MCA territories. Significance: This approach enables the potential use of DCS system for bilateral and vessel-specific monitoring of cerebral perfusion in the MCA territories.

bioengineering↗