Search bioRxiv⌕ Search

bioRxiv · 10.1101/2025.07.09.663792

Improving parameter inference by resolving Bayesian prior ambiguity via multi-dataset analysis: Application to isothermal titration calorimetry

Abstract

Isothermal titration calorimetry (ITC) is a powerful technique for probing biomolecular interactions. However, accurate determination of binding parameters--such as enthalpy and free energy--as well as associated uncertainties can be hindered by noise and concentration variability. Notably, the mathematical ambiguity surrounding analyte concentrations in standard binding models intrinsically limits the precision with which binding parameters, particularly binding enthalpies, can be determined. Here, we present a Bayesian pipeline that resolves this ambiguity by combining two key strategies: simultaneous analysis of multiple ITC datasets and a hierarchical Bayesian treatment of analyte concentration priors. This dual approach not only lifts the degeneracy inherent in single-dataset studies but also removes an ambiguity typically present in Bayesian analysis by self-consistently refining concentration estimates, ensuring optimal joint inference of binding parameters and concentrations. Using modern Monte Carlo techniques enables our pipeline to provide robust posterior sampling for more than 10 datasets and 40 total parameters. We validate the approach with synthetic ITC datasets for single- and multi-site binding models and apply it to experimental data, including 14 datasets for 1:1 binding of Mg(II) to the chelator EDTA and multiple datasets of the hub protein LC8 with diverse binding partners. This work serves as a foundation for improving the precision of binding constants using multiple ITC datasets, while providing a systematic framework for assessing the reliability of experimental concentration estimates, paving the way for more accurate biomolecular interaction studies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Otten, L., Walker, D. R., Barbar, E. J., Zuckerman, D. M.. 2025-07-11. Improving parameter inference by resolving Bayesian prior ambiguity via multi-dataset analysis: Application to isothermal titration calorimetry. https://doi.org/10.1101/2025.07.09.663792

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Design of colipids with controlled lateral distance of head group moieties for targeting strategies in the field of lipid-based nanoparticles

Lipid nanoparticles and liposomes are nanoparticle drug formulations which are firmly established in clinics. In order to expand their application and improve efficacy, surface modifications can be a key strategy, especially for cell specific targeting. Targeting can be achieved by integrating ligand functionalized lipids or lipidoids on the nanoparticle surface. In this case, not solely the targeting ligand itself, but also the structure of the whole targeting lipid/lipidoid can affect the interaction of the targeting ligand with the binding motive on cells. Especially, distal spacer structures between lipid anchor and ligand unit, often composed of polyethylene glycol chains, provide a certain distance of the ligand from the nanoparticle surface. A concept which is currently neglected is the control of the lateral distance between ligand structures on the nanoparticle. Herein we investigated the possibility to design lipidoids with a lateral spacer composed of polyethylene glycol units. We synthesized and characterized different lipidoids which provide a primary amine in the head group for possible ligand coupling. In our model lipidoids the head groups were functionalized with a paramagnetic probe to apply electron paramagnetic resonance (EPR) methods for the characterization of the lipidoid interaction with model nanoparticles, in our case liposomes. Continuous wave EPR was used to study the efficiency of the novel lipidoids to integrate into lipid bilayers of model liposomes, which was shown to depend on lipidoid structure and liposome composition. Furthermore, using double electron-electron resonance (DEER), we observed lipidoid conformational changes occurring upon integration into liposomes.

biophysics↗

Beyond Sequence and Structure: Pretraining PLMs on Continuous Biophysical Fields

We introduce the Biophysical Transformer, a protein language model that adds continuous biophysical fields as a third pretraining signal beside sequence and structure. A Poisson-Boltzmann solver computes the electrostatic potential around each three-residue token, and the model learns to predict it from sequence alone. A rotationally invariant spherical-harmonic descriptor serves as the loss target, eliminating the need for frame alignment during training and for coordinates at inference. Against a matched, one-flag control on the FLIP Meltome thermostability benchmark, the field objective raises Spearman correlation on every trained head of both human splits.The gain on human survives residualizing dipeptide composition under two architecturally different readouts and survives removing the test proteins that overlap the pretraining corpus. No effect survives on the organism-mixed split. At 1.1M parameters, both the Biophysical Transformer and its sequence-only control exceed FLIP's one-hot CNN and untrained-ESM baselines on every split. All results rest on a single pretraining run per arm,and the current design does not separate field content from generic regularization.

biophysics↗

An auditable harness for biomolecular dynamics simulations by AI agents

AI agents now generate biological hypotheses faster than they can be tested. Hypotheses stated at the atomic level can be examined with molecular dynamics (MD) simulations. For new questions without a reference, trust in an agent-run simulation rests on a tool-written process record, not the agent's account. Existing MD agents leave this record to the language model. Here we present MDClaw, a harness whose validating tools and directed acyclic graph (DAG) check stages before execution and record every simulation stage. On MDDataBench, which grades outputs against deposited simulations, four open-weight models with MDClaw passed all three runs on 81-100% of 31 test systems. The DAG complements this outcome check. An ablation without the DAG revealed 11 successful runs that had skipped minimization or equilibration, or simulated a different structure. MDClaw carried questions from human and AI scientists through simulation to trajectories traceable to their inputs and settings.

biophysics↗