Search bioRxiv⌕ Search

bioRxiv · 10.1101/2025.07.07.663371

Development and Characterization of a Tunable PDMS Substrate Model for Investigating Elastic Properties and Mechanical Stretching in Intervertebral Disc Mechanobiology

Abstract

BackgroundAberrant mechanical loading and altered extracellular matrix (ECM) composition favor catabolic cell responses, contributing to intervertebral disc (IVD) degeneration and ultimately impairing the integrity of the annulus fibrosus (AF). This highlights the need for new in vitro models to investigate the interplay of mechanical loading and cell-substrate interactions. Therefore, this study introduces a tunable stretching chamber platform to simultaneously study both factors in AF degeneration. MethodsTunable PDMS substrates were fabricated by adjusting ratios of Sylgard 184 and Sylgard 527, enabling molding into stretching chambers or well plates. Substrates underwent mechanical, optical and chemical characterization. Bovine AF cells were seeded onto the substrates and cultured under static conditions or subjected to cyclic strain (8% strain at 1 Hz). Substrate biocompatibility and cell morphology were assessed over 72 h in static cultures. Dynamic responses were assessed by cell viability and alignment. Digital Image Correlation (DIC) was employed to assess surface strain in custom-designed and commercial (STREX) stretching chambers at strains between 8 to 20%. ResultsPDMS formulations resulted in a stiffness (E modulus) range of 8.72 - 238.00 kPa, demonstrating distinct viscoelastic profiles. All substrate formulations supported AF cell adhesion and viability. DIC analysis revealed non-uniform axial and transverse strain distributions on membrane surfaces. Cyclic stretching showed that cells maintained viability up to 14 h. Additionally, cells responded to the applied strain by perpendicular alignment to the stretch axis at 6 h. ConclusionsThe PDMS based stretching platform offers a biocompatible and tunable mechanical environment that mimics physiological and pathophysiological elastic properties. It enables systematic investigations on how elastic properties and mechanical strain modulate AF cell behavior in IVD disease progression. Finally, this study raises the awareness of non-uniform and transverse strain components within the stretching chambers and highlights the discrepancy of effective strain transfer to the cell interaction surface.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wuertz-Kozak, K., Lamoca, M., Liu, R., Zhang, S., Lewis, C. L., Schimmelpfennig, K., Hasler, J.. 2025-07-10. Development and Characterization of a Tunable PDMS Substrate Model for Investigating Elastic Properties and Mechanical Stretching in Intervertebral Disc Mechanobiology. https://doi.org/10.1101/2025.07.07.663371

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗