Search bioRxiv⌕ Search

bioRxiv · 10.1101/2025.06.27.661893

All You Need Is Water: Converging Ligand Binding Simulations with Hydration Collective Variables

Abstract

Selecting appropriate collective variables (CVs) is a crucial bottleneck in enhanced sampling molecular dynamics (MD) simulations. Although progress has been made with data-driven and intuition-based approaches, optimal CVs remain system-specific. Meanwhile, simple geometric descriptors are still widely used due to their transferability. A promising, yet under-explored, candidate for a more efficient CV is solvation. Indeed, despite its central role in ligand binding and folding, the complexity of solvent behavior has hindered its widespread use. Here, we introduce a data-driven and automatic strategy to construct robust solvation-based CVs. Our method identifies critical hydration sites by analyzing the radial distribution function of water around a ligand. Remarkably, using only these hydration CVs within on-the-fly probability enhanced sampling (OPES) simulations, we successfully converge the binding free energy landscapes for a series of host-guest systems. These landscapes show excellent agreement with those from more computationally expensive benchmark methods. We further demonstrate that the choice of where to bias water is key to efficient convergence, providing clear guidelines for implementation. This work not only underscores the central role of water in molecular recognition but also offers a powerful and generalizable framework for enhancing the sampling of complex biomolecular events.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Schulze, M., Khakhula, T., Piasentin, N., Aureli, S., Rizzi, V., Gervasio, F. L.. 2025-07-01. All You Need Is Water: Converging Ligand Binding Simulations with Hydration Collective Variables. https://doi.org/10.1101/2025.06.27.661893

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Design of colipids with controlled lateral distance of head group moieties for targeting strategies in the field of lipid-based nanoparticles

Lipid nanoparticles and liposomes are nanoparticle drug formulations which are firmly established in clinics. In order to expand their application and improve efficacy, surface modifications can be a key strategy, especially for cell specific targeting. Targeting can be achieved by integrating ligand functionalized lipids or lipidoids on the nanoparticle surface. In this case, not solely the targeting ligand itself, but also the structure of the whole targeting lipid/lipidoid can affect the interaction of the targeting ligand with the binding motive on cells. Especially, distal spacer structures between lipid anchor and ligand unit, often composed of polyethylene glycol chains, provide a certain distance of the ligand from the nanoparticle surface. A concept which is currently neglected is the control of the lateral distance between ligand structures on the nanoparticle. Herein we investigated the possibility to design lipidoids with a lateral spacer composed of polyethylene glycol units. We synthesized and characterized different lipidoids which provide a primary amine in the head group for possible ligand coupling. In our model lipidoids the head groups were functionalized with a paramagnetic probe to apply electron paramagnetic resonance (EPR) methods for the characterization of the lipidoid interaction with model nanoparticles, in our case liposomes. Continuous wave EPR was used to study the efficiency of the novel lipidoids to integrate into lipid bilayers of model liposomes, which was shown to depend on lipidoid structure and liposome composition. Furthermore, using double electron-electron resonance (DEER), we observed lipidoid conformational changes occurring upon integration into liposomes.

biophysics↗

Beyond Sequence and Structure: Pretraining PLMs on Continuous Biophysical Fields

We introduce the Biophysical Transformer, a protein language model that adds continuous biophysical fields as a third pretraining signal beside sequence and structure. A Poisson-Boltzmann solver computes the electrostatic potential around each three-residue token, and the model learns to predict it from sequence alone. A rotationally invariant spherical-harmonic descriptor serves as the loss target, eliminating the need for frame alignment during training and for coordinates at inference. Against a matched, one-flag control on the FLIP Meltome thermostability benchmark, the field objective raises Spearman correlation on every trained head of both human splits.The gain on human survives residualizing dipeptide composition under two architecturally different readouts and survives removing the test proteins that overlap the pretraining corpus. No effect survives on the organism-mixed split. At 1.1M parameters, both the Biophysical Transformer and its sequence-only control exceed FLIP's one-hot CNN and untrained-ESM baselines on every split. All results rest on a single pretraining run per arm,and the current design does not separate field content from generic regularization.

biophysics↗

An auditable harness for biomolecular dynamics simulations by AI agents

AI agents now generate biological hypotheses faster than they can be tested. Hypotheses stated at the atomic level can be examined with molecular dynamics (MD) simulations. For new questions without a reference, trust in an agent-run simulation rests on a tool-written process record, not the agent's account. Existing MD agents leave this record to the language model. Here we present MDClaw, a harness whose validating tools and directed acyclic graph (DAG) check stages before execution and record every simulation stage. On MDDataBench, which grades outputs against deposited simulations, four open-weight models with MDClaw passed all three runs on 81-100% of 31 test systems. The DAG complements this outcome check. An ablation without the DAG revealed 11 successful runs that had skipped minimization or equilibration, or simulated a different structure. MDClaw carried questions from human and AI scientists through simulation to trajectories traceable to their inputs and settings.

biophysics↗