Search bioRxiv⌕ Search

bioRxiv · 10.1101/2025.05.26.652827

Human Skin Model from 15 GHz to 110 GHz

Abstract

In the recently revised guidelines for electromagnetic safety, basic restrictions expressed in terms of the absorbed power density (APD) at frequencies higher than 6 GHz were introduced. Testing for APD compliance of wireless devices requires experimental and numerical body models or phantoms that conservatively reproduce the absorption characteristics of human skin. Previous studies of APD indicate that frequency-dependent impedance-matching effects are caused by the low-permittivity stratum corneum (SC) layer. The objective of this study is to complement previous work (Christ et al., 2020) and to develop dispersive dielectric models to represent reflection and absorption of electromagnetic fields at the surface of the skin across a frequency range up to 110 GHz. The reflection coefficient of the skin of human volunteers was measured at frequencies of 15 to 43 GHz with open waveguide probes, complementing previous data from 45 to 110 GHz (Christ et al., 2020). The volunteers represented both sexes and different age groups and occupations; measurements were made at various regions of the body. The statistical analysis of the results show that the reflection coefficient follows a normal distribution in regions where the SC is relatively thin, which permits development of a conservative skin model that covers the 95th percentile of the tested population. As expected, in regions where the SC is thicker, e.g., the palms, the reflection coefficient is not normally distributed, because the thickness of the SC depends on the mechanical stress and friction to which the hands are exposed during routine daily activities. There was no evidence of relevant differences due to sex, but there is evidence for a slight age-dependent difference. The measured data - via fitting to the numerical model - allow the derivation of two-layer dielectric dispersive models that represent absorption and reflection at the surface of the skin with known uncertainty. The proposed models can be used to conservatively demonstrate compliance with the APD limits of wireless devices operating at frequencies of up to 110 GHz in any of the 5G and 6G bands defined. HighlightsO_LIbroadband evaluation of the skin reflection coefficient with open waveguide probes; C_LIO_LIcorroboration of increased absorption of millimeter wave radiation in body regions with increased stratum corneum thickness; C_LIO_LIdispersive dielectric models representing reflection and absorption at the skin surface with known population coverage. C_LI

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Christ, A., Aeschbacher, A., Tarigan, B., Chitnis, N., Fallahi, A., Kuehn, S., Capstick, M., Kuster, N.. 2025-05-28. Human Skin Model from 15 GHz to 110 GHz. https://doi.org/10.1101/2025.05.26.652827

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Surfactant-Assisted Colorimetric Signal Enhancement in Paper-Based Glucose Sensing

Paper-based colorimetric sensors offer a low-cost and accessible platform for point-of-care (POC) analysis, but enzyme activity loss during coating and drying can weaken analytical signals and require high enzyme loadings or complex immobilization procedures. Although surfactants are widely used to improve wettability in paper-based assays, their potential contribution to colorimetric performance beyond these effects remains unclear. Here, we investigated surfactant-assisted colorimetric signal enhancement in a glucose assay implemented on a 96-puddle paper plate (96-PPP) and identified Tween 20 as the most effective surfactant. Its effect on detection performance became more pronounced as glucose oxidase (GOx) loading decreased; at 0.1 mg/mL GOx, Tween 20 lowered the limit of detection (LoD) from 0.113 to 0.034 mg/mL (approximately 3.3-fold) over a working range of 0-5 mg/mL, despite no statistically significant change in the measured contact angle at this loading. Tween 20 had no appreciable effect on the reaction in solution but preserved 95% of the apparent reaction rate constant after drying, compared with 11% without it, and atomic force microscopy (AFM) revealed a more dispersed dried enzyme morphology on mica. Tween 20-containing sensors also showed slower signal decay during repeated wetting-drying cycles and thermal stress, retained 77% (vs 26%) of the response at 400 mM NaCl, and exhibited within-PPP and between-batch coefficients of variation (CVs) below 10% (vs 12.3-19.5%), while maintaining glucose selectivity over potentially interfering molecules. These results indicate that Tween 20 enhances paper-based glucose sensing beyond wettability, in part by retaining enzyme cascade activity during drying, although the contributions of the individual enzymes and the underlying mechanism remain to be established.

bioengineering↗

Engineering CAR-T cells to remodel the mucin-rich cancer cell glycocalyx

The dense glycocalyx of cancer cells can restrict immune-cell access to surface antigens and limit CAR-T cell activity. Here, we show that mucin density and epitope position determine how glycocalyx remodeling affects CAR-T cell recognition and killing. We identify KLK5 as a human protease that cleaves tumor-associated mucins, increases access to membrane-proximal antigens, and enhances CAR-T cell function. We then engineer CAR-T cells to display or secrete KLK5, enabling remodeling of the tumor glycocalyx during antigen recognition. KLK5-engineered CAR-T cells improved tumor control across multiple xenograft models, and KLK5-secreting MUC17 CAR-T cells produced the strongest in vivo benefit, prolonging survival compared with conventional MUC17 CAR-T cells. These findings show that CAR-T cells can be engineered to breach the mucin-rich glycocalyx while preserving accessible target epitopes.

bioengineering↗

Wall stiffening is a primary contributor to motility loss in Crohn's disease: an electromechanical modeling study

Fibrotic strictures are among the most disabling complications of Crohn's disease, permanently narrowing the bowel and impairing motility, yet no approved therapy reverses them. Chronic inflammation alters pacemaker-network coupling, smooth-muscle excitability, and calcium-dependent contractility, while fibrosis thickens the bowel wall, narrows the lumen, and changes tissue mechanics. The relative contributions of these coupled electrical, contractile, and structural alterations to motility loss remain unclear. To address this gap, we develop an integrated electromechanical finite-element framework for fibrostenosing Crohn's disease that couples a fibrosis-driven growth model with a FitzHugh-Nagumo electromechanical model. A full-factorial 25 design of experiments is used to quantify the relative effects of electrical diffusivity, excitation threshold, peak active stress, wall stiffness, and hypertrophic remodeling on cyclic lumen-volume deformation. Motility is quantified by the standard deviation of lumen volume over one contraction cycle. Within the parameter ranges examined, increased wall stiffness emerged as the dominant contributor to motility loss, followed by impaired smooth-muscle contractility. Changes in excitation threshold, hypertrophic remodeling, and electrical diffusivity produced substantially smaller effects. Pairwise interactions were small relative to the dominant main effects, indicating that the mechanisms contributed largely through their individual effects. Our findings suggest that limiting wall stiffening while preserving smooth-muscle contractile function may provide a therapeutic strategy for maintaining intestinal motility in fibrostenosing Crohn's disease.

bioengineering↗